A Comparison Between the Intubating Laryngeal Tube Suction and the Ambu AuraGain
A Prospective and Randomized Study Comparing the New Intubating Laryngeal Tube Suction and the Ambu AuraGain in Adult Patients
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The intubating Laryngeal Tube Suction-Disposable (iLTS-D) (VBM Medizintechnik GmbH, Sulz, Germany) is a new updated version of the Laryngeal Tube-Suction Disposable (LTS-D) It has a ventilator channel with a 13.5mm internal diameter, which enables the passage of an Endotracheal Tube (ETT) either blindly or with fiberoptic guidance. Similarly As in to the LTS-D, the iLTS-D also has a separate channel for the purpose of placement of gastric tubes placement up to a size of 18 Fr.
The iLTS-D comes in one size. According to the depth of insertion, this device is equivalent to size 4 for patients 175patients 175 to 190 cm tall, or size 5 for patients taller than 190 cm. The iLTS-D is provided by the manufacturer with a compatible 7.5mm ETT and with a plastic stabilizer for removal of the device.
The current randomized study was designed to assess the success rate of blind and fiberoptic endotracheal intubation using iLTS-D, in comparison with the and Ambu® AuraGain™ in adult patients under general anesthesia
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
American Society Anesthesiology I and II
Exclusion Criteria:
Difficult intubation, Cervical pathology
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Intubating laryngeal Tube Suction
|
Intubating Laryngeal Tube Suction
Ambu AuraGain Laryngeal Mask
|
|
Active Comparator: Ambu AuraGain Laryngeal Mask
|
Intubating Laryngeal Tube Suction
Ambu AuraGain Laryngeal Mask
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Time to performe blind intubation measure in second
Time Frame: 30 seconds
|
30 seconds
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Time to performe fiberoptic intubation in second
Time Frame: 60 seconds
|
60 seconds
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- BnaiZionMC-16-LG-005
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Intubation; Difficult
-
NCT03624439CompletedIntubation; Difficult or Failed | Difficult Airway | Intubation;Difficult
-
NCT01691703CompletedAnesthesia Intubation Complication | Intubation; Difficult | Failed or Difficult Intubation | Failed or Difficult Intubation, Initial Encounter
-
NCT04783584RecruitingDifficult Intubation | Difficult Airway Intubation
-
NCT02493478RecruitingIntubation Complication | Intubation; Difficult | Failed or Difficult Intubation, Sequela
-
NCT03194503CompletedIntubation Complication | Intubation;Difficult | Failed or Difficult Intubation, Sequela
-
NCT04105738TerminatedSurgery | Difficult Intubation | Anesthesia | Difficult Airway Intubation | Speech Dysfunction
-
NCT06986187RecruitingCardiac Surgery | Difficult Intubation | Difficult Airway | Difficult Airway Intubation | Cardiac Surgery in Adult Patient
-
NCT03545620CompletedDifficult Intubation | Difficult Airway
-
NCT07383610CompletedDifficult Intubation | Difficult Airway | Difficult Mask Ventilation
-
NCT03340207TerminatedIntubation Complication | Intubation;Difficult
Clinical Trials on Intubating Laryngeal Tube Suction
-
NCT05347680CompletedDifficult Intubation
-
NCT02884895UnknownAdverse Anesthesia Outcome
-
NCT04618926Not yet recruiting
-
NCT03067246CompletedAirway Management
-
NCT02977559UnknownAdverse Anesthesia Outcome
-
NCT02859922Completed
-
NCT02856672CompletedAdverse Anesthesia Outcome
-
NCT02877940Completed
-
NCT02866890UnknownAdverse Anesthesia Outcome