Competitive Accuracy of Radiological Imaging Compared to Liver Biopsy in Patients With Liver Fibrosis
Studieoversikt
Status
Status
Forhold
Forhold
Intervensjon / Behandling
Intervensjon / Behandling
Studietype
Studietype
Registrering (Faktiske)
Registrering
Kontakter og plasseringer
Studiesteder
-
-
-
Vilnius, Litauen, 211950810
- Vilnius University
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Prøvetakingsmetode
Studiepopulasjon
Beskrivelse
Inclusion Criteria:
- chronic liver disease
- signed informed consent
- liver biopsy indicated by treating gastroenterologist/infectologist
Exclusion Criteria:
- non-corrected blood coagulation tests
- acute liver disease
- age below 18 years or above 80 years
- disagreement to participate in the study
- pregnancy
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Observasjonsmodeller: Bare etui
- Tidsperspektiver: Potensielle
Antall grupper / kohorter
Kohorter og intervensjoner
Gruppe / KohortGruppe / Kohort |
Intervensjon / BehandlingIntervensjon / Behandling |
|---|---|
|
Patients with viral chronic liver disease at primary diagnosis
Patients with primary diagnosis of viral hepatitis B and hepatitis C who was referred for liver biopsy.
All patients underwent liver shear wave elastography and dynamic liver scintigraphy evaluating liver physical and functional changes shortly prior to liver biopsy procedure.
|
All patients were referred for 2D-SWE liver elastography and liver liver scintigraphy with 99mTc-mebrofenin prior to liver biopsy.
All patients were referred for 2D-SWE liver elastography and liver liver scintigraphy with 99mTc-mebrofenin prior to liver biopsy.
|
Hva måler studien?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Ultrasound elastography comparison to histological examination of liver biopsy specimen
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
|
Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen I
Tidsramme: Baseline only
|
Dynamic liver scintigraphy with 99mTc-mebrofenin parameter liver clearance (%/min/m2) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
|
Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen II
Tidsramme: Baseline only
|
Dynamic liver scintigraphy with 99mTc-mebrofenin parameter uptake time (min.) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
|
Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen III
Tidsramme: Baseline only
|
Dynamic liver scintigraphy with 99mTc-mebrofenin parameter liver excretion (30 min./peak
ratio) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Comparison of radiological imaging tests between each other I
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to liver clearance measured by dynamic liver scintigraphy with 99mTc-mebrofenin.
|
Baseline only
|
|
Comparison of radiological imaging tests between each other II
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to tracer excretion measured by dynamic liver scintigraphy with 99mTc-mebrofenin.
|
Baseline only
|
|
Comparison of radiological imaging tests between each other III
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to tracer uptake time measured by dynamic liver scintigraphy with 99mTc-mebrofenin.
|
Baseline only
|
Samarbeidspartnere og etterforskere
Sponsor
Sponsor
Etterforskere
Etterforskere
- Hovedetterforsker: Algirdas E Tamosiunas, MD, PhD, Vilnius University
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Studiestart
Primær fullføring (Faktiske)
Primær fullføring
Studiet fullført (Faktiske)
Studiet fullført
Datoer for studieregistrering
Først innsendt
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Først lagt ut
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Sist oppdatering lagt ut
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
Andre studie-ID-numre
- 158200-18/7-1053-552
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .