Competitive Accuracy of Radiological Imaging Compared to Liver Biopsy in Patients With Liver Fibrosis
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Kontakter og lokationer
Studiesteder
-
-
-
Vilnius, Litauen, 211950810
- Vilnius University
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
Inclusion Criteria:
- chronic liver disease
- signed informed consent
- liver biopsy indicated by treating gastroenterologist/infectologist
Exclusion Criteria:
- non-corrected blood coagulation tests
- acute liver disease
- age below 18 years or above 80 years
- disagreement to participate in the study
- pregnancy
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Observationsmodeller: Kun etui
- Tidsperspektiver: Fremadrettet
Antal grupper/kohorter
Kohorter og interventioner
Gruppe / kohorteGruppe / kohorte |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Patients with viral chronic liver disease at primary diagnosis
Patients with primary diagnosis of viral hepatitis B and hepatitis C who was referred for liver biopsy.
All patients underwent liver shear wave elastography and dynamic liver scintigraphy evaluating liver physical and functional changes shortly prior to liver biopsy procedure.
|
All patients were referred for 2D-SWE liver elastography and liver liver scintigraphy with 99mTc-mebrofenin prior to liver biopsy.
All patients were referred for 2D-SWE liver elastography and liver liver scintigraphy with 99mTc-mebrofenin prior to liver biopsy.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Ultrasound elastography comparison to histological examination of liver biopsy specimen
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
|
Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen I
Tidsramme: Baseline only
|
Dynamic liver scintigraphy with 99mTc-mebrofenin parameter liver clearance (%/min/m2) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
|
Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen II
Tidsramme: Baseline only
|
Dynamic liver scintigraphy with 99mTc-mebrofenin parameter uptake time (min.) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
|
Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen III
Tidsramme: Baseline only
|
Dynamic liver scintigraphy with 99mTc-mebrofenin parameter liver excretion (30 min./peak
ratio) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment.
|
Baseline only
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Comparison of radiological imaging tests between each other I
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to liver clearance measured by dynamic liver scintigraphy with 99mTc-mebrofenin.
|
Baseline only
|
|
Comparison of radiological imaging tests between each other II
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to tracer excretion measured by dynamic liver scintigraphy with 99mTc-mebrofenin.
|
Baseline only
|
|
Comparison of radiological imaging tests between each other III
Tidsramme: Baseline only
|
Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to tracer uptake time measured by dynamic liver scintigraphy with 99mTc-mebrofenin.
|
Baseline only
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Efterforskere
Efterforskere
- Ledende efterforsker: Algirdas E Tamosiunas, MD, PhD, Vilnius University
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 158200-18/7-1053-552
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .