Vibration Response Imaging (VRI) in Patients Who Are Potential Candidates for Surgical Resection
The primary purpose of the study is to investigate the use of VRI to guide the selection of patients for lung surgery. Perfusion scintigraphy is the current method to assess the fractional contribution of lung function of the remaining lung.
The hypothesis is that VRI can determine quantitative postoperative lung function equally accurately as a quantitative perfusion scan.
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Typ studiów
Typ studiów
Zapisy (Oczekiwany)
Zapisy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Connecticut
-
New Haven, Connecticut, Stany Zjednoczone, 06520-8062
- Yale University School Of Medicine
-
-
Georgia
-
Atlanta, Georgia, Stany Zjednoczone, 30322
- Emory University
-
-
Massachusetts
-
Boston, Massachusetts, Stany Zjednoczone, 02118
- Boston Medical Center, Boston University
-
-
New York
-
New York, New York, Stany Zjednoczone, 10029
- Mt. Sinai School of Medicine
-
New York, New York, Stany Zjednoczone, 10032
- New York-Presbyterian Hospital/Columbia University Medical Center
-
-
Texas
-
Houston, Texas, Stany Zjednoczone, 77030
- The University of Texas MD Anderson Cancer Center
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Able and willing to read, understand, and provide written Informed Consent;
- Age range of 18-90 years;
- Potential candidate for at least lobectomy due to lung cancer or other intrathoracic malignancy (either suspected or proven by biopsy). Both open and minimally invasive (thoracoscopic) resections are acceptable.
- BMI > 19.
Exclusion Criteria:
- Body habitus or skin condition that might prevent the placement of the sound sensors on the back (e.g. severe scoliosis, kyphosis, chest wall deformation, skin lesion on the back or compression fracture);
- There should be no active pulmonary infection (e.g. pneumonia) at the time of the recordings;
- Hirsutism unless patient is willing to have back shaved;
- Potentially contagious skin lesion on the back;
- Giant bulla (more than 1/3 of the hemithorax or >10cm)
- Pregnant women
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Liczba grup / kohort
Kohorty i interwencje
Grupa / KohortaGrupa / Kohorta |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Lung resection candidates
Study participants will be patients who are candidates for lung resection (lobectomy or greater)
|
The study is designed in a way that will not alter the surgeon's decision based on routine assessment of candidates for resection (lobectomy or greater).
Namely, the VRI data will be gathered prospectively; however, the analyses using VRI data will be performed retrospectively.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
|---|---|
|
Comparison of ppo FEV1 and ppo DLCO as predicted by VRI with the values as predicted by Q scan
Ramy czasowe: Prior to surgery
|
Prior to surgery
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Ramy czasowe |
|---|---|
|
Comparison of ppo as predicted by each test with the actual FEV1 and DLCO at 3 months post-operative
Ramy czasowe: 3 months after surgery
|
3 months after surgery
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: Frank C Detterbeck, MD, Yale University Medical School
Publikacje i pomocne linki
Publikacje ogólne
- Dellinger RP, Parrillo JE, Kushnir A, Rossi M, Kushnir I. Dynamic visualization of lung sounds with a vibration response device: a case series. Respiration. 2008;75(1):60-72. doi: 10.1159/000103558. Epub 2007 Jun 4.
- Kramer MR, Raviv Y, Hardoff R, Shteinmatz A, Amital A, Shitrit D. Regional breath sound distribution analysis in single-lung transplant recipients. J Heart Lung Transplant. 2007 Nov;26(11):1149-54. doi: 10.1016/j.healun.2007.07.039.
- Guntupalli KK, Reddy RM, Loutfi RH, Alapat PM, Bandi VD, Hanania NA. Evaluation of obstructive lung disease with vibration response imaging. J Asthma. 2008 Dec;45(10):923-30. doi: 10.1080/02770900802395496.
- Yigla M, Gat M, Meyer JJ, Friedman PJ, Maher TM, Madison JM. Vibration response imaging technology in healthy subjects. AJR Am J Roentgenol. 2008 Sep;191(3):845-52. doi: 10.2214/AJR.07.3151.
- Becker HD, Slawik M, Miyazawa T, Gat M. Vibration response imaging as a new tool for interventional-bronchoscopy outcome assessment: a prospective pilot study. Respiration. 2009;77(2):179-94. doi: 10.1159/000182972. Epub 2008 Dec 9.
- Colice GL, Shafazand S, Griffin JP, Keenan R, Bolliger CT; American College of Chest Physicians. Physiologic evaluation of the patient with lung cancer being considered for resectional surgery: ACCP evidenced-based clinical practice guidelines (2nd edition). Chest. 2007 Sep;132(3 Suppl):161S-77S. doi: 10.1378/chest.07-1359.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Oczekiwany)
Zakończenie podstawowe
Ukończenie studiów (Oczekiwany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- DB041
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .