Calibre vs. COSMED
Correlation of Cardiopulmonary Exercise Testing (CPET) VO2 Max Parameters Between the Calibre Device and COSMED Metabolic Cart
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Szacowany)
Zapisy
Faza
Faza
- Nie dotyczy
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Age 18-55
- Able to speak English
- Able to provide informed consent
Exclusion Criteria:
- Acute myocardial infarction
- Unstable angina
- Syncope
- Uncontrolled asthma
- Arterial desaturation at rest on room air <85%
- Severe untreated arterial hypertension at rest (>200 mm Hg systolic, >120 mm Hg diastolic)
- Significant pulmonary hypertension
- Active thrombosis of the lower extremity, unless treated for at least 2 weeks prior to participation.
- Within 2 weeks of acute symptomatic pulmonary embolus
- Considered inappropriate to participate by Principal Investigator
- Previously experienced a heart attack
- Pregnancy
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Brak (otwarta etykieta)
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: Calibre First Sequence
Participants undergo cardiopulmonary exercise testing using the investigational Calibre device during Visit 1, followed by testing with the COSMED Quark CPET reference system during Visit 2 (at least 2 days later).
|
Investigational wearable facemask device with integrated sensors for breath-by-breath measurement of respiratory gas exchange and ventilatory parameters during cardiopulmonary exercise testing, evaluated against the COSMED Quark CPET reference system.
|
|
Eksperymentalny: COSMED First Sequence
Participants undergo cardiopulmonary exercise testing using the COSMED Quark CPET reference system during Visit 1, followed by testing with the investigational Calibre device during Visit 2 (at least 2 days later).
|
FDA-cleared cardiopulmonary exercise testing (CPET) metabolic cart used as the reference comparator for measurement of respiratory gas exchange and ventilatory parameters during ramp cycle ergometry.
Participants wear a facemask connected to the system for breath-by-breath measurement of oxygen consumption (VO2), carbon dioxide production (VCO2), minute ventilation (VE), anaerobic threshold, and ventilatory efficiency during maximal exercise testing.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
VO₂ peak correlation, as measured by Pearson or Spearman correlation coefficient between Calibre and COSMED
Ramy czasowe: During CPET testing across Visit 1 and Visit 2, up to 7 days.
|
VO₂ peak measured during CPET will be compared between devices using Pearson or Spearman correlation coefficient, depending on data distribution.
|
During CPET testing across Visit 1 and Visit 2, up to 7 days.
|
|
VO₂ peak agreement, as measured by Bland-Altman bias and limits of agreement between Calibre and COSMED
Ramy czasowe: During CPET testing across Visit 1 and Visit 2, up to 7 days.
|
VO₂ peak measured during CPET will be compared between devices using Bland-Altman analysis to estimate average bias and limits of agreement.
|
During CPET testing across Visit 1 and Visit 2, up to 7 days.
|
|
Anaerobic threshold correlation, as measured by Pearson or Spearman correlation coefficient between Calibre and COSMED
Ramy czasowe: During CPET testing across Visit 1 and Visit 2, up to 7 days
|
Anaerobic threshold measured during CPET will be compared between devices using Pearson or Spearman correlation coefficient, depending on data distribution.
|
During CPET testing across Visit 1 and Visit 2, up to 7 days
|
|
Anaerobic threshold agreement, as measured by Bland-Altman bias and limits of agreement between Calibre and COSMED
Ramy czasowe: During CPET testing across Visit 1 and Visit 2, up to 7 days
|
Anaerobic threshold measured during CPET will be compared between devices using Bland-Altman analysis to estimate average bias and limits of agreement.
|
During CPET testing across Visit 1 and Visit 2, up to 7 days
|
|
VE/VCO₂ correlation, as measured by Pearson or Spearman correlation coefficient between Calibre and COSMED
Ramy czasowe: During CPET testing across Visit 1 and Visit 2, up to 7 days
|
Ventilatory equivalent for carbon dioxide (VE/VCO₂) measured during CPET will be compared between devices using Pearson or Spearman correlation coefficient, depending on data distribution.
|
During CPET testing across Visit 1 and Visit 2, up to 7 days
|
|
VE/VCO₂ agreement, as measured by Bland-Altman bias and limits of agreement between Calibre and COSMED
Ramy czasowe: During CPET testing across Visit 1 and Visit 2, up to 7 days
|
Ventilatory equivalent for carbon dioxide (VE/VCO₂) measured during CPET will be compared between devices using Bland-Altman analysis to estimate average bias and limits of agreement.
|
During CPET testing across Visit 1 and Visit 2, up to 7 days
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Główny śledczy: David MacLeod, M.B.B.S., Duke University
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Rozpoczęcie studiów
Zakończenie podstawowe (Szacowany)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- Pro00118791
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .