Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Ablation With Transcatheter Edge-to-edge Repair for Atrial Functional Mitral Regurgitation and Atrial Fibrillation (ATTRACTION)

2 sierpnia 2026 zaktualizowane przez: Mao Chen

Ablation wiTh TRAnsCatheter Edge-to-edge Repair Versus ablaTION Alone for Atrial Functional Mitral Regurgitation and Atrial Fibrillation (ATTRACTION Study)

This trial is a randomized study for patients with significant atrial functional mitral regurgitation (AFMR) and atrial fibrillation (AF). The composite endpoint of all-cause mortality, cardiovascular-related hospitalizations, AF recurrence, and quality of life improvement is hypothesized to be superior with the combination of transcatheter edge-to-edge repair (TEER) and catheter ablation, compared with catheter ablation alone.

Przegląd badań

Status

Jeszcze nie rekrutacja

Warunki

Interwencja / Leczenie

Szczegółowy opis

Rationale:

The introduction of transcatheter edge-to-edge repair (TEER) for the treatment of functional mitral regurgitation (FMR) has led to a significant reduction in mortality and heart failure hospitalizations. However, the optimal timing and intervention for patients with atrial functional mitral regurgitation (AFMR) have not been evaluated in clinical trials. Published clinical trials, including COAPT, MITRA-FR, and RESHAPE-HF, did not classify functional mitral regurgitation according to ventricular or atrial origin. Concerns regarding the role of atrial fibrillation (AF) as a potential trigger of atrial dilatation and a consequence of atrial remodeling have led to recommendations for rhythm control in selected patients. Given the high incidence of AFMR among patients with persistent AF, successful ablation and maintenance of sinus rhythm may remain challenging. Therefore, concomitant TEER and catheter ablation are hypothesized to provide greater clinical benefit compared with catheter ablation alone.

Aim:

The purpose of this study is to evaluate the efficacy of TEER combined with catheter ablation in patients with significant AFMR and AF, focusing on clinical outcomes and atrial reverse remodeling.

Study design:

Patients with moderate-to-severe or severe AFMR and AF will be enrolled in a randomized, open-label, controlled study. Patients will be randomized in a 1:1 ratio to receive TEER combined with catheter ablation or catheter ablation alone. The study duration is anticipated to include 24 months of enrollment and 12 months of follow-up.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

384

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kopia zapasowa kontaktu do badania

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Opis

Inclusion Criteria:

  • Age ≥ 18 years
  • Left ventricular ejection fraction ≥ 50%
  • Grading of MR: 3+ or 4+ (effective regurgitant orifice area≥30mm2, regurgitant volume ≥45ml)
  • Valve morphology: MR originating from the mid portion of the valve; mitral valve area> 4 cm2; Length of posterior leaflet ≥10 mm; Sufficient leaflet tissue for mechanical coaptation: coaptation depth< 11 mm, coaptation length> 2 mm
  • Rate control in suspected AF-induced cardiomyopathy (heart rate <80 bpm at rest and <110 bpm during exercise)
  • Patients must be willing to comply with all follow-up requirements

Exclusion Criteria:

  • Life expectancy< 1 year due to non-cardiac conditions
  • Primary mitral regurgitation: valve abnormalities including leaflet tethering from LV dysfunction, intrinsic leaflet pathology (prolapse, flail, calcification, severe thickening), mitral annular calcification (either severe or <severe but extending into the leaflets), and/or any mixed pathology
  • Active endocarditis of the mitral valve or rheumatic mitral valve disease
  • Hypotension (systolic pressure < 90 mmHg) or requirement for inotropic support or mechanical hemodynamic support
  • Severe tricuspid regurgitation; Physical evidence of right-sided congestive heart failure with echocardiographic evidence of severe right ventricular dysfunction; Fixed pulmonary artery systolic pressure> 70 mmHg
  • Stroke/TIA, TAVR, CRT/ CRT-D/ ICD, cardiac intervention or surgery within 30 days before randomization
  • Any prior MV surgery or transcatheter procedure
  • Need for any cardiac surgery (other than for MV disease)
  • Untreated clinically significant coronary artery disease
  • Echocardiographic evidence of intracardiac thrombus
  • Active infections requiring current antibiotic therapy
  • Patients who cannot tolerate anti-platelet/anticoagulation agents/contrast media
  • Pregnancy
  • Any condition making it unlikely the patient will be able to complete all protocol procedures (including compliance with medical therapy) and follow-up visits
  • Patient (or legal guardian) unable or unwilling to provide written informed consent before study enrollment

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: TEER+Ablation
Patients will undergo catheter ablation and transcatheter edge to edge repair.
Participants will undergo catheter ablation for persistent atrial fibrillation followed by transcatheter edge-to-edge repair (TEER) for the treatment of functional mitral regurgitation during the same hospitalization. TEER will be performed using an approved transcatheter mitral valve repair system to reduce mitral regurgitation severity and improve cardiac function.
Inne nazwy:
  • TEER
Participants will undergo catheter ablation for persistent atrial fibrillation during the study period. The procedure will include pulmonary vein isolation with additional ablation strategies as clinically indicated.
Aktywny komparator: Catheter ablation
Patients will undergo catheter ablation only.
Participants will undergo catheter ablation for persistent atrial fibrillation during the study period. The procedure will include pulmonary vein isolation with additional ablation strategies as clinically indicated.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Hierarchical Composite Clinical Endpoint (Win Ratio)
Ramy czasowe: 12 months
The primary endpoint is a single hierarchical composite clinical endpoint analyzed by pairwise comparison. Each participant in the transcatheter edge-to-edge repair (TEER) plus catheter ablation group is compared with each participant in the catheter ablation alone group, in order of clinical priority: all-cause mortality, cumulative cardiovascular-related hospitalization, atrial fibrillation recurrence, and change in quality of life measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ). Each pairwise comparison is resolved at the highest-priority component that differs between the two participants, and results in a single "win," "loss," or "tie." The treatment effect is summarized as one win ratio, defined as the total number of wins divided by the total number of losses across all pairs, comparing the TEER plus catheter ablation group with the catheter ablation alone group.
12 months

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Incidence of 30-day composite safety events
Ramy czasowe: 30 days
The composite safety endpoint includes cardiovascular mortality, stroke, myocardial infarction, acute kidney injury, major bleeding, and non-elective cardiovascular surgery for device-related complications within 30 days after the procedure.
30 days
Change in mitral regurgitation grade from baseline
Ramy czasowe: 12 months
Mitral regurgitation severity will be assessed by transthoracic echocardiography according to an integrated approach recommended by current guidelines. The outcome will be the proportion of patients achieving mild or less mitral regurgitation (grade ≤2) at 12 months.
12 months
Composite of all-cause mortality and cardiovascular-related hospitalization
Ramy czasowe: 12 months
The composite endpoint includes all-cause mortality and cardiovascular-related hospitalization within 12 months. Death events will be identified through follow-up records, and cardiovascular-related hospitalizations will be confirmed by medical record review according to predefined criteria.
12 months
Cardiovascular mortality
Ramy czasowe: 12 months
Cardiovascular mortality is defined as death caused by cardiovascular causes and will be determined through review of medical records and clinical documentation.
12 months
Heart failure hospitalizations
Ramy czasowe: 12 months
Heart failure hospitalization is defined as an unplanned admission lasting ≥24 hours due to acute decompensated heart failure, with symptoms, signs, and/or laboratory evidence of heart failure and requiring intravenous or mechanical heart failure therapies. Events will be identified through medical records and adjudicated according to predefined criteria.
12 months
Incidence of stroke or transient ischemic attack
Ramy czasowe: 12 months
Stroke and transient ischemic attack events will be identified through clinical assessment, medical records, and neuroimaging findings. Stroke will be classified as ischemic or hemorrhagic according to clinical diagnosis and imaging evaluation.
12 months
Change in left atrial volume index
Ramy czasowe: 12 months
Left atrial volume index is assessed by the biplane method of disks and indexed to body surface area.
12 months
Change in left atrial reservoir function from baseline
Ramy czasowe: 12 months
Left atrial reservoir function will be assessed using speckle-tracking echocardiography, and the change from baseline to 12 months will be evaluated.
12 months
Change in severity of tricuspid regurgitation from baseline
Ramy czasowe: 12 months
Tricuspid regurgitation severity will be assessed by transthoracic echocardiography using an integrated approach according to current guidelines. The change in tricuspid regurgitation severity from baseline to 12 months will be evaluated.
12 months
Change in NYHA functional classification from baseline
Ramy czasowe: 12 months
The New York Heart Association (NYHA) functional class will be assessed by clinical evaluation based on patients' symptoms and limitations during physical activity. The change from baseline to 12 months will be evaluated.
12 months
Change in N-terminal pro-B-type natriuretic peptide (NT-proBNP) level from baseline
Ramy czasowe: 12 months
Plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels will be measured using standard laboratory assays. The change from baseline to 12 months will be evaluated.
12 months

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Współpracownicy

Śledczy

  • Główny śledczy: Mao Chen, West China Hospital

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Publikacje ogólne

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

1 września 2026

Zakończenie podstawowe (Szacowany)

1 września 2028

Ukończenie studiów (Szacowany)

1 września 2029

Daty rejestracji na studia

Pierwszy przesłany

18 lipca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

2 sierpnia 2026

Pierwszy wysłany (Rzeczywisty)

4 sierpnia 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

4 sierpnia 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

2 sierpnia 2026

Ostatnia weryfikacja

1 sierpnia 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 2026-286

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .