Speech Perception, Spatial Perception and Satisfaction Outcomes of Fitting Based on Hearing In Noise Ability
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Szczegółowy opis
Hypotheses:
H0: Using ACT in the fitting is not more effective than the traditional fitting method in improving speech understanding performance in noise in hearing aid users.
H1: Using ACT in the fitting is more effective than the traditional fitting method in improving speech understanding performance in noise in hearing aid users.
H0: Using ACT in the fitting is not more effective than the traditional fitting method in improving spatial perception performance in hearing aid users.
H1: Using ACT in the fitting is more effective than the traditional fitting method in improving spatial perception performance in hearing aid users.
H0: Using ACT in the fitting does not increase speech understanding performance in noise in hearing aid users.
H1: Using ACT in the fitting increases speech understanding performance in noise in hearing aid users.
H0: Using ACT in the fitting has no effect on improving spatial perception performance in hearing aid users.
H1: Using ACT in the fitting has an effect on improving spatial perception performance in hearing aid users.
H0: Using ACT in fitting has no effect on increasing hearing aid satisfaction in hearing aid users.
H1: Using ACT in fitting has an effect on increasing hearing aid satisfaction in hearing aid users.
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Kucukcekmece
-
Istanbul, Kucukcekmece, Turcja (Türkiye), 34295
- Istanbul Aydın University
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Medium (41-55 dB) / moderate to severe (56-70 dB), sensorineural hearing loss (Goodman, 1965)
- SDS score between 70-100%
- Being a bilateral hearing aid user
- Being a user of Oticon, Philips, Bernafon hearing aids
- Being between 18-50 years of age
- Signing an informed consent form
Exclusion Criteria:
- Conditions with variable hearing loss such as Meniere's disease, ongoing treatment with ototoxic drugs
- Complaining with tinnitus
- Low cognitive capacity: Scoring below 24 on the Standardized Mini Mental Test
- Not signing an informed consent form
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Badania usług zdrowotnych
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Pojedynczy
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Aktywny komparator: Experimental Group
The ACT method will be applied to the study group in fitting, and the results will be recorded by applying the KUİK scale and APHAB survey after fitting.
They will be called for control in the 1st week and 1st month, and fitting and scale evaluations will be made and the results will be recorded.
Participants' discrimination in noise with ACT and Turkish Matrix Test, evaluation of spatial perception with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be evaluated in the initial and 1st month time periods.
|
The ACT diagnostic test is a suprathreshold, non-language-specific test that measures an individual's hearing ability in real-world noisy environments to determine the level of assistance needed in noise.
The test uses the audiogram shape and levels to ensure the correct stimulus intensity is applied.
The ACT test then uses the patient's audiogram to present a suprathreshold stimulus (a siren-like sound) to objectively map their hearing ability in noisy environments.
In other words, the audiogram measures quantity, i.e. hearing ability, while the ACT measures the quality of hearing.
This makes the ACT a robust assessment that reflects an individual's real-world hearing abilities.
Inne nazwy:
|
|
Aktywny komparator: Control Group
The control group will be fitted with traditional fittings, and the results will be recorded using the KUİK scale and APHAB survey after fitting.
Fitting and scale assessments will be made at week 1 and month 1, and the results will be recorded.
Participants' ability to discriminate in noise with the ACT and Turkish Matrix Test, spatial perception assessment with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be assessed at the beginning and month 1.
|
The control group will be fitted with traditional fittings, and the results will be recorded using the KUİK scale and APHAB survey after fitting.
They will be called for a check-up at week 1 and month 1, and fitting and scale assessments will be made, and the results will be recorded.
Participants' ability to discriminate in noise with the ACT and Turkish Matrix Test, spatial perception with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be assessed at the beginning and month 1.
All findings will be compared and statistically analyzed.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Eco-HINT
Ramy czasowe: 1 week and 1 month after hearing aid fitting
|
Speech-in-noise performance was assessed using the ecologically valid Hearing in Noise Test (eco-HINT).
Speech reception thresholds were measured under aided and unaided listening conditions.
Lower scores indicate better speech-in-noise performance.
|
1 week and 1 month after hearing aid fitting
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Speech, Spatial Perception and Hearing Quality Scale
Ramy czasowe: 1 week and 1 month after hearing aid fitting
|
The individual who is applied the scale evaluates himself/herself and answers each question between 0 and 10 points.
All scores are added up and divided by 49 to obtain the "General KUİK score".
The scores under the heading of Speech Perception are added up and divided by 14 to obtain the KA score, the scores under the heading of Spatial Perception are added up and divided by 17 to obtain the UA score, and the scores under the heading of Hearing Quality are added up and divided by 18 to obtain the İK score.
|
1 week and 1 month after hearing aid fitting
|
|
APHAB survey
Ramy czasowe: 1 week and 1 month after hearing aid fitting
|
APHAB is a survey that allows us to numerically measure the benefits and satisfaction of individuals with hearing loss from their hearing aids in daily hearing situations.
Survey questions are answered according to two different listening situations: "without my hearing aid" and "with my hearing aid".
|
1 week and 1 month after hearing aid fitting
|
Inne miary wyników
Inne miary wyników
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Audible Contrast Threshold (ACT)
Ramy czasowe: Time Frame: 1 week and 1 month after hearing aid fitting
|
The ACT is a suprathreshold, non-language-specific test that measures an individual's ability to hear in real-world noisy environments to determine the level of assistance needed in noise.
ACT values are determined by level of intensity.
A normal ACT value is between -4 and +4 dB nCL. 4 to 7 dB nCL indicates mild loss, 7 to 10 dB nCL indicates moderate loss, and 10 to 16 dB nCL indicates profound loss.
|
Time Frame: 1 week and 1 month after hearing aid fitting
|
Współpracownicy i badacze
Sponsor
Sponsor
Śledczy
Śledczy
- Dyrektor Studium: Sule Cekic, associate professor, Ankara Yildirim Beyazıt University
- Dyrektor Studium: Umıt Can Cetinkaya, assistant professor, Istanbul Aydın University
Publikacje i pomocne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
- Zachowanie
- Zachowanie przestrzenne
- Orientacja, przestrzenny
- Zjawiska fizjologiczne mięśniowo -szkieletowe i nerwowe
- Zdrowie publiczne
- Środowisko i zdrowie publiczne
- Zjawiska fizjologiczne
- Zjawiska fizyczne
- Środowisko
- Zjawiska ekologiczne i środowiskowe
- Zjawiska biologiczne
- Promieniowanie
- Promieniowanie, nieonizujące
- Zjawiska fizjologiczne układu nerwowego
- Dźwięk
- Uczucie
- Zanieczyszczenie środowiska
- Zjawiska fizjologiczne przedsionkowe
- Hałas
- Przesłuchanie
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- 61351342/020-385
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Opis planu IPD
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .