Comparison of Noninvasive Blood Glucose Concentrations Relative to Finger Capillary Blood Glucose References

23 lutego 2012 zaktualizowane przez: InLight Solutions

An Evaluation and Comparison of Noninvasive Blood Glucose Concentrations Relative to Finger Capillary Blood Glucose References

The purpose of the study is to prospectively evaluate a noninvasive, near-infrared based method for measuring glucose concentration relative to invasive blood reference measurements. The initial phase of the study will be focused on procurement of the data needed to develop a robust, accurate calibration. The second phase will be focused on performance evaluation of the system.

Przegląd badań

Szczegółowy opis

Currently, individuals with diabetes must use an invasive finger stick methodology for the determination of their blood glucose levels. Although current technology glucose meters use a smaller amount of blood than older generation meters, the pain and inconvenience associated with this invasive measurement is the number one reason cited for inadequate or infrequent blood glucose monitoring. In fact up to 67% of patients with diabetes fail to routinely monitor their blood glucose levels. A survey of 1895 patients showed that finger soreness was the most common reason given for self-reported noncompliance with testing recommendations, followed by pain, inconvenience, fear of needles, and "other" (including cost), (Diabetes Care August 2001 vol. 24 no. 8 1502-1503). The ability to make a painless blood glucose measurement using only light would address the pain and inconvenience issues associated with current technology glucose meters.

The initial application of the technology is associated with the monitoring of Gestational Diabetes. The International Association of Diabetes and Pregnancy Study Groups (IADPSG) recently released recommendations for diagnosing gestational diabetes, as well as clarifying the benefits of treatment (Diabetes Care, 2010;33:676-682). The IADPSG cited research that found significant graded relationships between increasing maternal glucose levels and the frequency of four primary and five secondary outcomes. For example, with a 1-standard deviation increase in maternal fasting, 1-hour, and 2-hour plasma glucose levels, there was a corresponding 38%, 46%, and 38% increased risk, respectively, in the primary outcome of birth weight >90th percentile, and a 5%, 18%, and 16% increased risk, respectively, of the secondary outcome of premature delivery before 37 weeks gestation (N Engl J Med 2008;358:1991-2002).

Typ studiów

Obserwacyjny

Zapisy (Oczekiwany)

100

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

    • New Mexico
      • Albuquerque, New Mexico, Stany Zjednoczone, 87106
        • Lovelace Scientific Resources

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

20 lat do 50 lat (Dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Kobieta

Metoda próbkowania

Próbka prawdopodobieństwa

Badana populacja

The Human Subject population consists of female subjects between the ages of 20 and 50. Subjects must have been diagnosed with either Type I, Type II, or Gestational diabetes and may utilize healthy individuals for the validation phase. Up to 100 subjects may be recruited to participate in this study. Subjects will be recruited from the community and will be selected to ensure a representative sample of the projected intended use population. Efforts will also be made to ensure a broad and even distribution of ages (between 20 and 50 years old) and ethnicities.

Opis

Inclusion Criteria:

  • Female at least 20 years of age but not older than 50 years of age
  • Female with Type I or Gestational diabetes based on ADA criteria
  • Female with Type II diabetes and A1c of greater than 7.0 as measured on a Bayer A1C Now meter
  • May include female healthy volunteers.

Exclusion Criteria:

  • Subject requires hemo-dialysis
  • Severe heart disease as evidenced by peripheral edema
  • Liver disease as evidenced by jaundice
  • Active alcohol or drug abuse
  • Body Mass Index (BMI) > 35 kg/m2
  • Hand size too large to fit in the optical measurement instrumentation
  • Middle finger width of less than 5 mm
  • Skin damage at optical sampling site on hand
  • Currently taking prednisone or other systemic steroids
  • Tattoo at the optical sampling site

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Type 2 Diabetes
Those previously diagnosed with type 2 diabetes
Type 1 Diabetes
Those previously diagnosed with type 1 diabetes
Gestational Diabetes
Those that are currently diagnosed with gestational diabetes
Healthy Human Volunteers
Those that have not been diagnosed with any type of diabetes

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Calibrate near-infrared spectroscopy-based glucose meter
Ramy czasowe: 1 year
The collection of capillary blood glucose and noninvasive data will allow the calibration of the noninvasive systems and subsequently evaluate performance via a validation study. The paired NIR spectrum and blood reference data acquired during calibration will be processed using multivariate regression techniques to create a calibration model. Results will be compared using a Clark error grid.
1 year

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Compare Noninvasive to invasive techniques
Ramy czasowe: 1 year
Comparison of noninvasive glucose measurement performance versus standard invasive reference. Invasive measurements are made by obtaining capillary blood glucose measurements and then measuring blood on a Yellow Springs Instrument (YSI). Due to the fact that instrumentation drift and subject physiological changes can adversely influence measurement performance, the study is specifically designed to examine performance over an appropriate period of time with a reasonable distribution of subject variance. Results will be compared using a Clark error grid.
1 year

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Walter Forman, MD, Lovelace Scientific Resources

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów

1 czerwca 2011

Zakończenie podstawowe (Oczekiwany)

1 lutego 2012

Ukończenie studiów (Oczekiwany)

1 lutego 2012

Daty rejestracji na studia

Pierwszy przesłany

9 sierpnia 2011

Pierwszy przesłany, który spełnia kryteria kontroli jakości

10 sierpnia 2011

Pierwszy wysłany (Oszacować)

12 sierpnia 2011

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Oszacować)

27 lutego 2012

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

23 lutego 2012

Ostatnia weryfikacja

1 lutego 2012

Więcej informacji

Terminy związane z tym badaniem

Słowa kluczowe

Inne numery identyfikacyjne badania

  • 10-0020

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .