- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT03863132
DOKŁADNA OCENA KORZYŚCI Z OPTYMALNEGO LECZENIA MEDYCZNEGO Z ZASTAWKĄ PRZEZCEWNIKOWĄ LUB NIE Naprawa paradoksalnego zwężenia zastawki aortalnej przy niskim przepływie o niskim gradiencie (REBOOT-PARADOX)
Optymalne leczenie medyczne z naprawą zastawki lub bez niej u pacjentów z objawowym paradoksalnym zwężeniem zastawki aortalnej o niskim przepływie i niskim gradiencie — wieloośrodkowe, randomizowane porównanie
Aim of this study is to evaluate whether microsurgical repair or replacement of the aortic valve is a treatment option for a subgroup of patients suffering from aortic Stenosis.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
Stenosis of the aortic valve leads to a narrowing of the valve, consequently to low blood flow from the heart into the Aorta, and is associated with symptoms like fatigue, breathlessness, dizziness, fainting, and chest pain. For many of the patients suffering from severe aortic stenosis surgical or catheter-assisted repair or replacement of the damaged aortic valve has been proven to be a safe and effective treatment option.
Probably about 20-30% of patients suffering from severe aortic stenosis display a deviation from the usually observed disease pattern: These patients do not show the typical high pressure difference between the left ventricle (heart chamber) and the aorta (transvalvular gradient; "paradoxical" low flow/low gradient aortic stenosis). For these patients it is not yet clear, if microsurgical repair of the aortic valve (transcatheter aortic valve repair - TAVR) should be a treatment option as well.
REBOOT-PARADOX evaluates whether TAVR is advantageous compared to optimal medical Treatment alone for patients suffering from paradoxical aortic stenosis. Two thirds of the participating patients will be treated by TAVR, one third will receive medical Treatment alone.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Baden-Wurttemberg
-
Tübingen, Baden-Wurttemberg, Niemcy, 72076
- Universitätsklinikum Tübingen
-
-
Bavaria
-
München, Bavaria, Niemcy, 80636
- Deutsches Herzzentrum München
-
München, Bavaria, Niemcy, 81377
- Klinikum der Universität München-Großhadern
-
-
Free and Hanseatic City of Hamburg
-
Hamburg, Free and Hanseatic City of Hamburg, Niemcy, 20246
- Universitäres Herz- u. Gefäßzentrum Hamburg
-
-
Hesse
-
Bad Nauheim, Hesse, Niemcy
- Kerckhoff-Klinik GmbH
-
-
Lower Saxony
-
Bad Bevensen, Lower Saxony, Niemcy, 29549
- Herz- und Gefäßzentrum Bad Bevensen
-
-
Mecklenburg-Vorpommern
-
Rostock, Mecklenburg-Vorpommern, Niemcy, 18057
- Universitätsmedizin Rostock, Klinik und Poliklinik für Kardiologie
-
-
North Rhine-Westphalia
-
Bad Oeynhausen, North Rhine-Westphalia, Niemcy, 32545
- Herz- und Diabeteszentrum Nordrhein-Westfalen Bad Oeynhausen
-
Cologne, North Rhine-Westphalia, Niemcy, 50937
- Herzzentrum der Universität Köln
-
-
Rhineland-Palatinate
-
Ludwigshafen am Rhein, Rhineland-Palatinate, Niemcy
- Klinikum der Stadt Ludwigshafen a. Rh.
-
-
Saxony
-
Leipzig, Saxony, Niemcy
- Herzzentrum Leipzig
-
-
Schleswig-Holstein
-
Bad Segeberg, Schleswig-Holstein, Niemcy
- Segeberger Kliniken, Herzzentrum
-
-
-
-
-
Zurich, Szwajcaria, 8091
- Universitätsspital Zürich, Universitätres Herzzentrum Zürich
-
-
-
-
-
Milan, Włochy, 20089
- Humanitas Mirasole S.P.A
-
Pisa, Włochy, 56126
- Azienda Ospedaliero Universitaria Pisana
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- I1. Patients with symptomatic native aortic valve stenosis and age ≥18 years
- I2. Aortic valve area (AVA) ≤ 1 cm2 or indexed AVA ≤ 0.6 cm2/m2, mean aortic gradient < 40 mmHg and stroke volume index (SVI) < 35ml/m2
- I3. Left ventricular ejection fraction ≥ 50%
- I4. MDCT aortic valve calcium score men > 2000AU, women > 1200AU OR the likelihood criteria are fulfilled (symptoms without other explanation and LV hypertrophy; age < 70 yrs., AVS < 0.8 cm2; SVI < 35ml/m2 confirmed by 3D TOE, MRI or invasive; reduced LV longitudinal function without other reason)
- I5. Heart team agrees on eligibility for TAVR
- I6. Written informed consent
- I7. Negative pregnancy test in women with childbearing potential
Exclusion Criteria:
- E1. Hemodynamic instability
- E2. Cardiogenic shock
- E3. Pre-existing mechanical or bio-prosthetic valve in any position
- E4. Concomitant severe valvular heart disease
- E5. Pre-existing or active endocarditis
- E6. Need for heart surgery due to other conditions
- E7. Aortic valve is congenital unicuspid or congenital bicuspid
- E8. Hypertrophic cardiomyopathy with or without obstruction
- E9. Echocardiographic evidence of intracardiac mass, thrombus or vegetation
- E10. Acute myocardial infarction within 1 month before intended AS-treatment
- E11. Renal replacement therapy
- E12. Estimated life expectancy < 24 months (730 days) due to carcinomas end stage liver disease or renal disease
- E13. Currently participating in an investigational drug or another device study. Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials.
- E14. Patient refuses aortic valve repair
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: TAVR Group
Patients will be treated by transcatheter aortic valve repair (TAVR). |
Repair of defective aortic valve by microsurgical Intervention. |
|
Brak interwencji: Medical Treatment Group
Patients will receive optimal medical treatment alone. |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Time to death
Ramy czasowe: 24 months after last-patient-in
|
All-cause mortality |
24 months after last-patient-in
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Cardiovascular mortality
Ramy czasowe: 5 years after index treatment
|
Death because of cardiovascular events |
5 years after index treatment
|
|
Re-hospitalization due to heart failure
Ramy czasowe: 5 years after index treatment
|
Number of hospital stays after randomization |
5 years after index treatment
|
|
Incidence of neurological events - incidence of strokes
Ramy czasowe: 5 years after randomization
|
Number of strokes |
5 years after randomization
|
|
Incidence of neurological Events - incidence of transient ischaemic attacks
Ramy czasowe: 5 years after randomization
|
Number of transient ischaemic attacks |
5 years after randomization
|
|
Cardiac functionality - left ventricular function
Ramy czasowe: 5 years after randomization
|
Echocardiographic measurement of left ventricular ejection fraction in % |
5 years after randomization
|
|
Cardiac functionality - aortic valve hemodynamics
Ramy czasowe: 5 years after randomization
|
Measurement of aortic pressure in mmHg |
5 years after randomization
|
|
Patients' quality of life
Ramy czasowe: 5 years after randomization
|
EQ5D-score in % |
5 years after randomization
|
|
Device reliability
Ramy czasowe: 5 years after randomization
|
Number of reinterventions (TAVR arm only) |
5 years after randomization
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Steffen Massberg, Prof. Dr., University Clinic Munich
Publikacje i pomocne linki
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- REBOOT-PARADOX
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .