- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT03863132
Evaluación precisa del beneficio con tratamiento médico óptimo con o sin reparación de válvula transcatéter de estenosis aórtica PARADOXical de bajo flujo y bajo gradiente (REBOOT-PARADOX)
Tratamiento médico óptimo con o sin reparación de válvula en pacientes con estenosis aórtica paradójica sintomática de bajo flujo y bajo gradiente: una comparación aleatoria multicéntrica
Aim of this study is to evaluate whether microsurgical repair or replacement of the aortic valve is a treatment option for a subgroup of patients suffering from aortic Stenosis.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Stenosis of the aortic valve leads to a narrowing of the valve, consequently to low blood flow from the heart into the Aorta, and is associated with symptoms like fatigue, breathlessness, dizziness, fainting, and chest pain. For many of the patients suffering from severe aortic stenosis surgical or catheter-assisted repair or replacement of the damaged aortic valve has been proven to be a safe and effective treatment option.
Probably about 20-30% of patients suffering from severe aortic stenosis display a deviation from the usually observed disease pattern: These patients do not show the typical high pressure difference between the left ventricle (heart chamber) and the aorta (transvalvular gradient; "paradoxical" low flow/low gradient aortic stenosis). For these patients it is not yet clear, if microsurgical repair of the aortic valve (transcatheter aortic valve repair - TAVR) should be a treatment option as well.
REBOOT-PARADOX evaluates whether TAVR is advantageous compared to optimal medical Treatment alone for patients suffering from paradoxical aortic stenosis. Two thirds of the participating patients will be treated by TAVR, one third will receive medical Treatment alone.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Baden-Wurttemberg
-
Tübingen, Baden-Wurttemberg, Alemania, 72076
- Universitätsklinikum Tübingen
-
-
Bavaria
-
München, Bavaria, Alemania, 80636
- Deutsches Herzzentrum München
-
München, Bavaria, Alemania, 81377
- Klinikum der Universität München-Großhadern
-
-
Free and Hanseatic City of Hamburg
-
Hamburg, Free and Hanseatic City of Hamburg, Alemania, 20246
- Universitäres Herz- u. Gefäßzentrum Hamburg
-
-
Hesse
-
Bad Nauheim, Hesse, Alemania
- Kerckhoff-Klinik GmbH
-
-
Lower Saxony
-
Bad Bevensen, Lower Saxony, Alemania, 29549
- Herz- und Gefäßzentrum Bad Bevensen
-
-
Mecklenburg-Vorpommern
-
Rostock, Mecklenburg-Vorpommern, Alemania, 18057
- Universitätsmedizin Rostock, Klinik und Poliklinik für Kardiologie
-
-
North Rhine-Westphalia
-
Bad Oeynhausen, North Rhine-Westphalia, Alemania, 32545
- Herz- und Diabeteszentrum Nordrhein-Westfalen Bad Oeynhausen
-
Cologne, North Rhine-Westphalia, Alemania, 50937
- Herzzentrum der Universität Köln
-
-
Rhineland-Palatinate
-
Ludwigshafen am Rhein, Rhineland-Palatinate, Alemania
- Klinikum der Stadt Ludwigshafen a. Rh.
-
-
Saxony
-
Leipzig, Saxony, Alemania
- Herzzentrum Leipzig
-
-
Schleswig-Holstein
-
Bad Segeberg, Schleswig-Holstein, Alemania
- Segeberger Kliniken, Herzzentrum
-
-
-
-
-
Milan, Italia, 20089
- Humanitas Mirasole S.P.A
-
Pisa, Italia, 56126
- Azienda Ospedaliero Universitaria Pisana
-
-
-
-
-
Zurich, Suiza, 8091
- Universitätsspital Zürich, Universitätres Herzzentrum Zürich
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- I1. Patients with symptomatic native aortic valve stenosis and age ≥18 years
- I2. Aortic valve area (AVA) ≤ 1 cm2 or indexed AVA ≤ 0.6 cm2/m2, mean aortic gradient < 40 mmHg and stroke volume index (SVI) < 35ml/m2
- I3. Left ventricular ejection fraction ≥ 50%
- I4. MDCT aortic valve calcium score men > 2000AU, women > 1200AU OR the likelihood criteria are fulfilled (symptoms without other explanation and LV hypertrophy; age < 70 yrs., AVS < 0.8 cm2; SVI < 35ml/m2 confirmed by 3D TOE, MRI or invasive; reduced LV longitudinal function without other reason)
- I5. Heart team agrees on eligibility for TAVR
- I6. Written informed consent
- I7. Negative pregnancy test in women with childbearing potential
Exclusion Criteria:
- E1. Hemodynamic instability
- E2. Cardiogenic shock
- E3. Pre-existing mechanical or bio-prosthetic valve in any position
- E4. Concomitant severe valvular heart disease
- E5. Pre-existing or active endocarditis
- E6. Need for heart surgery due to other conditions
- E7. Aortic valve is congenital unicuspid or congenital bicuspid
- E8. Hypertrophic cardiomyopathy with or without obstruction
- E9. Echocardiographic evidence of intracardiac mass, thrombus or vegetation
- E10. Acute myocardial infarction within 1 month before intended AS-treatment
- E11. Renal replacement therapy
- E12. Estimated life expectancy < 24 months (730 days) due to carcinomas end stage liver disease or renal disease
- E13. Currently participating in an investigational drug or another device study. Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials.
- E14. Patient refuses aortic valve repair
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: TAVR Group
Patients will be treated by transcatheter aortic valve repair (TAVR). |
Repair of defective aortic valve by microsurgical Intervention. |
|
Sin intervención: Medical Treatment Group
Patients will receive optimal medical treatment alone. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Time to death
Periodo de tiempo: 24 months after last-patient-in
|
All-cause mortality |
24 months after last-patient-in
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Cardiovascular mortality
Periodo de tiempo: 5 years after index treatment
|
Death because of cardiovascular events |
5 years after index treatment
|
|
Re-hospitalization due to heart failure
Periodo de tiempo: 5 years after index treatment
|
Number of hospital stays after randomization |
5 years after index treatment
|
|
Incidence of neurological events - incidence of strokes
Periodo de tiempo: 5 years after randomization
|
Number of strokes |
5 years after randomization
|
|
Incidence of neurological Events - incidence of transient ischaemic attacks
Periodo de tiempo: 5 years after randomization
|
Number of transient ischaemic attacks |
5 years after randomization
|
|
Cardiac functionality - left ventricular function
Periodo de tiempo: 5 years after randomization
|
Echocardiographic measurement of left ventricular ejection fraction in % |
5 years after randomization
|
|
Cardiac functionality - aortic valve hemodynamics
Periodo de tiempo: 5 years after randomization
|
Measurement of aortic pressure in mmHg |
5 years after randomization
|
|
Patients' quality of life
Periodo de tiempo: 5 years after randomization
|
EQ5D-score in % |
5 years after randomization
|
|
Device reliability
Periodo de tiempo: 5 years after randomization
|
Number of reinterventions (TAVR arm only) |
5 years after randomization
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Steffen Massberg, Prof. Dr., University Clinic Munich
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- REBOOT-PARADOX
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .