In hospitalized patients diagnosed with COVID-19, diabetes mellitus is associated with a higher mortality. Patients with controlled blood glucose have a lower mortality rate than those who are uncontrolled. However, a rigid blood glucose control - which may lead to hypoglycemia- is associated with higher mortality rates. Thus, adequate glucose monitoring is important for hospitalized diabetic patients.
Previous studies have shown that CGMS, in the outpatient setting, engender better glycemic control thereby reducing risk of hypoglycemia. CGMS offer a replacement for finger stick blood glucose monitoring which may not identify an incidence of hypoglycemia until symptoms drive the patient to test. Furthermore, finger stick blood glucose monitoring is painful and time consuming thus causing many patients to avoid this aspect of diabetes self-care management.
Freestyle Libre CGMs sample interstitial fluid glucose subcutaneously. Measurement frequencies typically range from 1 to 15 minutes and most commonly are every 5 minutes.
Previous studies in hospitalized patients living with diabetes mellitus on basal bolus regimen have shown:
• Use of the CGM increased detection of both hypoglycemic and hyperglycemic events versus those sensed by POCT.
One investigation identified 88 postprandial hyperglycemic excursions in patients with CGM use as opposed to 61 in those with POCT. Another noted that when comparing the CGM use with that of POCT, the former identified 55 hypoglycemic events whereas the latter only found 12.
• No difference in mean daily glucose CGM and POCT readings. In a study of 38 patients, the investigators noted no difference in mean daily glucose between the CGM and POCT.
Tipo de estudo
Tipo de estudo
Inscrição (Real)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
New York
-
New York, New York, Estados Unidos, 10022
- Lenox Hill Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Participants acquired from among all non-critical care in patients who are living with Diabetes Mellitus. Because the patients will have to be instructed on the use of the CGM, this study will be limited to English speaking/reading adults (18 years of age or older), who possess the cognitive and physical ability to participate.
Exclusion Criteria:
- Minors, pregnant women, and critically ill.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Outro
- Alocação: Não randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Nenhum (rótulo aberto)
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Outro: Freestyle Libre 14-day CGM
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
|
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
The Accu-Chek Inform II system is designed to deliver data with speed and efficiency, helping to provide optimal care.
Wireless meter quickly transfers data.
The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless technology at the meter level.
|
|
Outro: Accuchek Inform II meter
ACCU-CHEK INFORM II system quantitatively measures glucose in fresh venous, arterial, neonatal heel stick and capillary whole blood from the finger and is used as an aid in monitoring the effectiveness of glucose control
|
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
The Accu-Chek Inform II system is designed to deliver data with speed and efficiency, helping to provide optimal care.
Wireless meter quickly transfers data.
The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless technology at the meter level.
|
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Comparison of values between two devices
Prazo: Through end of patient hospitalization, an average of 14 days
|
Correlation between blood glucose results from the Freestlye Libre 14-day CGM and Accuchek Inform II platform using the Bland-Altman method to determine whether the two glucose methods agree
|
Through end of patient hospitalization, an average of 14 days
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Investigadores
Investigadores
- Investigador principal: Renee Murray-Bachmann, Ed.D, MSN, Northwell Health
Publicações e links úteis
Links úteis
- Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: A Multicenter, Open-Label Randomize
- Zhu, L., Zhi-Gang, S., Cheng, S., Guo, J., Bing-Hong, Z.,Hongliang, L. (2020).Association of blood glucose control and outcomes in patients with COVID-19 and pre-existing Type 2 Diabetes Cell Metabolism, 31, (2020).pp.1-10
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Início do estudo
Conclusão Primária (Real)
Conclusão Primária
Conclusão do estudo (Real)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
Outros números de identificação do estudo
- 20-0455
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .