Predicting Peritoneal Kt/Vurea Based on Single-Exchange Dialysate Effluent
Development and Validation of a Prediction Model for Peritoneal Kt/Vurea Using Single-Exchange Dialysate Effluent in Patients Undergoing Peritoneal Dialysis
Background:
Peritoneal dialysis (PD) adequacy is routinely evaluated using the urea clearance index (Kt/Vurea), a key indicator of small-solute clearance and treatment adequacy. The standard method for calculating peritoneal Kt/Vurea requires complete collection of 24-hour dialysate effluent, which is labor-intensive, time-consuming, and prone to errors arising from incomplete collection, inadequate mixing, and inaccurate sampling. Although proportional sampling from each exchange has been shown to yield results comparable to those obtained from complete 24-hour effluent collection, this approach still requires collection of all exchanges throughout the day. Previous studies have suggested that Kt/Vurea estimated from a single dialysate exchange may correlate with the standard measurement; however, these investigations were limited by small sample sizes and did not establish predictive equations. Therefore, a practical and accurate alternative for assessing peritoneal Kt/Vurea is still lacking.
Objective:
To develop and validate a prediction model for peritoneal Kt/Vurea based on single-exchange dialysate effluent in patients undergoing PD.
Methods:
This multicenter cross-sectional study will be conducted between 2026 and 2027 across four PD centers in China. Consecutive prevalent patients receiving manual PD will be screened for eligibility. Patients aged ≥14 years who have been receiving PD for at least one month will be included. Exclusion criteria comprise peritonitis or other acute complications within the preceding month, spontaneous ascites, inability to complete full dialysate collection during the study day, and refusal to provide informed consent. Demographic characteristics, primary kidney disease, comorbidities, and PD prescription parameters will be collected. On a designated study day, effluent from each dialysis exchange, 24-hour urine samples, and fasting blood samples will be obtained. The correlations between peritoneal Kt/Vurea calculated from individual exchanges and the reference peritoneal Kt/Vurea derived from complete 24-hour dialysate collection will be evaluated. Multivariable prediction models incorporating single-exchange effluent measurements and relevant clinical parameters will subsequently be developed and validated. Model performance will be assessed using measures of discrimination, calibration, and agreement with reference Kt/Vurea values.
Conclusions:
This study aims to establish and validate a simplified method for estimating peritoneal Kt/Vurea using single-exchange dialysate effluent. If validated, the proposed model may substantially reduce the burden associated with 24-hour dialysate collection while maintaining adequate accuracy for routine assessment of PD adequacy.
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
Tipo de estudo
Tipo de estudo
Inscrição (Estimado)
Inscrição
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
- Filho
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
Patients aged ≥14 years who have been receiving PD for at least one month.
Exclusion Criteria:
(1) peritonitis or other acute complications (e.g., severe infection or acute heart failure) within 1 month prior to enrollment; (2) spontaneous ascites; (3) inability to complete full collection of all dialysate effluent during the study dialysis day; (4) refusal or inability to provide written informed consent.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Prazo |
|---|---|
|
Accuracy of prediction of peritoneal Kt/Vurea using single-exchange dialysate effluent
Prazo: Baseline (single assessment)
|
Baseline (single assessment)
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Início do estudo
Conclusão Primária (Estimado)
Conclusão Primária
Conclusão do estudo (Estimado)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
Outros números de identificação do estudo
- Peritoneal Kt/Vurea
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .