DL Models Predicting Cycloplegic Refractive Error Based on Non-Cycloplegic Parameters in Myopic Adults

7 de julho de 2026 atualizado por: Jian Xiong, Second Affiliated Hospital of Nanchang University

Efficacy of Deep Learning Models for Predicting Cycloplegic Refractive Error Based on Non-Cycloplegic Parameters in Adults With Myopia

This study presents a machine learning model that predicts cycloplegic refraction in adults with myopia using standard non-cycloplegic eye measurements, aiming to reduce the need for cycloplegic drops while still identifying patients who require them.

Visão geral do estudo

Status

Recrutamento

Condições

Intervenção / Tratamento

Descrição detalhada

Myopia is a highly prevalent, irreversible refractive disorder with substantial impact on quality of life. Cycloplegic refraction is the gold standard for assessing refractive error in adults considering optical or surgical correction, but it is time-consuming, slow to recover from, and frequently associated with ocular discomfort. Non-cycloplegic refraction is therefore used routinely in clinical practice, despite known differences from cycloplegic values in a subset of adult myopes.

Critically, this discrepancy varies substantially between individuals and cannot be anticipated from non-cycloplegic measurements alone. Clinicians have no reliable way to identify, prior to dilation, which patients are likely to be overcorrected if cycloplegia is omitted, potentially leading to overcorrected prescriptions, asthenopia, and myopic progression.

Machine learning approaches that capture non-linear relationships between clinical predictors and refractive outcomes have shown promise in children, but comparable models for adults remain largely unexplored, and most rely on axial length, which is unavailable in routine optometric settings. Refractive surgery centers offer a uniquely suitable data source, as every candidate undergoes standardized paired non-cycloplegic and cycloplegic refraction with detailed anterior segment biometry during routine preoperative evaluation. This study leverages such data to develop and validate models estimating cycloplegic refractive error from non-cycloplegic parameters, providing a decision-support tool that reduces unnecessary cycloplegia while flagging patients for whom dilated refraction remains indicated.

Tipo de estudo

Observacional

Inscrição (Estimado)

2500

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Estude backup de contato

Locais de estudo

      • Jiangxi, China
        • Recrutamento
        • The Second Affiliated Hospital of Nanchang University, Nanchang, JiangXi 330000
        • Contato:
        • Contato:

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto

Aceita Voluntários Saudáveis

Não

Método de amostragem

Amostra Não Probabilística

População do estudo

Each subject underwent a comprehensive preoperative examination, including cycloplegic and non-cycloplegic refractions, Pentacam, etc.

Descrição

Inclusion Criteria:

  1. Age 18 to 60 years, of either sex;
  2. Spherical equivalent between -0.50 diopters and -10.00 diopters, with myopia in one or both eyes, and with cylinder of 4.00 diopters or less;
  3. Best-corrected visual acuity of 20/25 or better in each eye;
  4. Clear cornea, no keratoconus, corneal scarring, or other pathologies; clear lens;
  5. Intraocular pressure of 21 mmHg or less, with no history of glaucoma;
  6. No history of ocular surgery, especially corneal refractive surgery or cataract surgery;
  7. Time interval between non-cycloplegic refraction and cycloplegic refraction of 7 days or less, with complete data.

Exclusion Criteria:

  1. Incomplete clinical data to support the diagnosis;
  2. Ocular conditions such as subclinical keratoconus, keratoconus, or moderate-to-severe corneal haze or leukoma;
  3. Allergy or contraindication to cycloplegic agents;
  4. Refusal to participate in the study.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
Group with spherical equivalent change ≥0.50 diopters after cycloplegic refraction
Adult myopes with a non-cycloplegic versus cycloplegic spherical equivalent difference of ≥0.50 diopters, for whom cycloplegic refraction is clinically warranted, received routine cycloplegic refraction with tropicamide; no other intervention was given.
The machine learning model was applied to each participant's non-cycloplegic parameters to predict cycloplegic spherical equivalent.
Group with spherical equivalent change <0.50 diopters after cycloplegic refraction
Adult myopes with an absolute difference of less than 0.50 diopters between non-cycloplegic and cycloplegic spherical equivalent, for whom non-cycloplegic refraction is considered sufficient, received routine cycloplegic refraction with tropicamide; no additional intervention was applied.
The machine learning model was applied to each participant's non-cycloplegic parameters to predict cycloplegic spherical equivalent.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Accuracy of predicted cycloplegic spherical equivalent
Prazo: Day 0
Accuracy of the machine learning model in predicting cycloplegic spherical equivalent in the validation dataset, evaluated by mean absolute error, root mean square error, and coefficient of determination, expressed for spherical equivalent in diopters.
Day 0

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Diagnostic performance for identifying patients requiring cycloplegic refraction
Prazo: Day 0
Area under the receiver operating characteristic curve, sensitivity, and specificity of the model for classifying patients with an absolute difference of 0.50 diopters or more between non-cycloplegic and cycloplegic spherical equivalent in the validation dataset.
Day 0
Agreement between predicted and measured cycloplegic refraction
Prazo: Day 0
Agreement between predicted and measured cycloplegic spherical equivalent assessed by Bland-Altman analysis with mean bias and 95% limits of agreement, and by the intraclass correlation coefficient in the validation dataset.
Day 0

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

3 de outubro de 2023

Conclusão Primária (Estimado)

25 de novembro de 2026

Conclusão do estudo (Estimado)

25 de novembro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

21 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

5 de julho de 2026

Primeira postagem (Real)

8 de julho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

9 de julho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

7 de julho de 2026

Última verificação

1 de julho de 2026

Mais Informações

Termos relacionados a este estudo

Termos MeSH relevantes adicionais

Outros números de identificação do estudo

  • [2026] NO.(123)

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .