LIFU Effects & Outcomes: Mechanisms Evaluating Striatal Systems Imaging (LEO MESSI) (MESSI-LEO)
Mechanisms of Low-intensity Focused Ultrasound Targeting Striatal Circuits Underlying Auditory Hallucinations in Schizophrenia
Visão geral do estudo
Status
Status
Condições
Condições
Intervenção / Tratamento
Intervenção / Tratamento
Descrição detalhada
Background:
Auditory hallucinations affect approximately 70% of individuals with schizophrenia and often persist despite antipsychotic treatment, contributing substantially to disability and reduced quality of life. Neuroimaging studies have consistently demonstrated abnormal functional connectivity between the striatum and superior temporal cortex, implicating corticostriatal circuitry in the generation and maintenance of hallucinations. Among striatal regions, the caudate has been associated with aberrant self-monitoring, abnormal predictive processing, and hallucination severity, making it a promising therapeutic target. The current study builds on these findings by evaluating whether non-invasive neuromodulation of the caudate can normalize striatal-temporal network function and improve hallucination symptoms.
Study Objective:
This first-in-human, early Phase 1 investigator-initiated clinical trial will evaluate the safety, feasibility, tolerability, target engagement, and preliminary mechanistic effects of repeated-session low-intensity focused ultrasound (LIFU) targeting the caudate, a key striatal region implicated in auditory hallucinations in schizophrenia. The study will determine whether individualized LIFU can safely modulate deep corticostriatal circuits and reduce hallucination-related functional connectivity abnormalities while improving psychotic hallucination symptoms.
Study Design:
Participants with schizophrenia and persistent clinically significant auditory hallucinations will undergo MRI-guided, neuronavigated LIFU targeting an individualized caudate target, a key striatal region implicated in hallucination-related corticostriatal circuitry. The study incorporates repeated-session stimulation with sham control to evaluate safety, feasibility, neural target engagement, and preliminary efficacy. Resting-state functional MRI will be obtained before and after treatment to quantify changes in functional connectivity between the caudate and superior temporal cortex. Clinical outcomes will include validated measures of auditory hallucination severity, psychiatric symptoms, tolerability, and adverse events.
Scientific Rationale:
LIFU provides a unique capability to non-invasively modulate deep brain structures with millimeter spatial precision that cannot be reached using conventional non-invasive brain stimulation approaches. By targeting the caudate, this study seeks to directly test the causal role of striatal circuitry in hallucination generation and determine whether modulation of corticostriatal connectivity produces measurable improvements in hallucination symptoms. The results will establish the safety and feasibility of this approach while providing mechanistic evidence to guide future randomized efficacy trials of circuit-based neuromodulation for schizophrenia.
Safety and Feasibility of LIFU This study has been designated a non-significant risk (NSR) device study by the UCSF Institutional Review Board and follows International Transcranial Ultrasonic Stimulation Safety and Standards Consortium (ITRUSST) recommendations. Individualized MRI-guided targeting and subject-specific acoustic simulations will optimize focal targeting while maintaining acoustic exposure within established safety limits. Participants will undergo continuous monitoring during treatment, structured adverse-event assessments using Common Terminology Criteria for Adverse Events (CTCAE) criteria, repeated tolerability assessments, and psychiatric safety monitoring throughout the study. Preliminary studies demonstrated that caudate-targeted LIFU was well tolerated, with no device-related adverse events beyond mild transient auditory sensations, supporting the safety and feasibility of repeated-session caudate-targeted LIFU in schizophrenia.
Tipo de estudo
Tipo de estudo
Inscrição (Estimado)
Inscrição
Estágio
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
Contato de estudo
- Nome: Karuna Subramaniam, PhD
- Número de telefone: 415-813-9795
- E-mail: karuna.subramaniam@ucsf.edu
Locais de estudo
-
-
California
-
San Francisco, California, Estados Unidos, 94158
- University of California, San Francisco
-
-
Critérios de participação
Critérios de elegibilidade
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- 18-64 years of age, inclusive of all gender identities
- Current DSM-5 diagnosis of schizophrenia
- Persistent clinically-significant auditory hallucinations
- No contraindications for MRI, confirmed via standard safety screening procedures
- No neurological disorder
- Clinically stable (outpatient past 12 weeks; same dose medications in 4 weeks)
- Females will be tested for pregnancy and pregnant women will be excluded.
Exclusion Criteria:
Clinically significant neurological disorder or MRI incompatibility
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Solteiro
Número de braços
Armas e Intervenções
Grupo de Participantes / BraçoGrupo de Participantes / Braço |
Intervenção / TratamentoIntervenção / Tratamento |
|---|---|
|
Comparador Ativo: Active LIFU
Active LIFU targeting teh caudate
|
MRI-guided, neuronavigated low-intensity focused ultrasound (LIFU) delivered to the caudate target will be compared to sham unfocused sonication delivered using the same device and procedures as the active intervention but without focal ultrasound energy to the target.
Outros nomes:
|
|
Comparador de Placebo: Sham Sonication
Sham Unfocused Sonication
|
MRI-guided, neuronavigated low-intensity focused ultrasound (LIFU) delivered to the caudate target will be compared to sham unfocused sonication delivered using the same device and procedures as the active intervention but without focal ultrasound energy to the target.
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Auditory Hallucinations
Prazo: Baseline and Post-Treatment (Weekly follow-up for 8 weeks)
|
We will compare hallucinations after LIFU to caudate with baseline and the sham unfocused sonication condition using the Visual Analog Scale (VAS) and Auditory Vocal Hallucination Rating Scales (AVHRS).
|
Baseline and Post-Treatment (Weekly follow-up for 8 weeks)
|
|
Caudate-superior temporal cortical (STC) connectivity
Prazo: Baseline and Post-Treatment ( Day 5)
|
We will compare functional connectivity using Fisher r-to-z values from the CONN toolbox between the caudate and STC after LIFU compared to baseline and the sham unfocused sonication condition
|
Baseline and Post-Treatment ( Day 5)
|
Medidas de resultados secundários
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Clinical Positive and Negative Symptoms
Prazo: Baseline and Post-Treatment (Weekly follow-up for 8 weeks)
|
We will compare positive and negative symptoms using the Positive and Negative Syndrome Scale (PANSS) after LIFU targeting the caudate with baseline and the sham unfocused sonication condition.
|
Baseline and Post-Treatment (Weekly follow-up for 8 weeks)
|
Colaboradores e Investigadores
Patrocinador
Patrocinador
Colaboradores
Colaboradores
Investigadores
Investigadores
- Investigador principal: Karuna Subramaniam, PhD, karuna.subramaniam@ucsf.edu
Publicações e links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Início do estudo
Conclusão Primária (Estimado)
Conclusão Primária
Conclusão do estudo (Estimado)
Conclusão do estudo
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Primeira postagem
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última Atualização Postada
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
Outros números de identificação do estudo
- 24-42726
- 1685505 (Número de outro subsídio/financiamento: Focused Ultrasound Foundation)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .