Comparison of the Conor Sirolimus-eluting Coronary Stent to the Taxus Liberte Paclitaxel-eluting Coronary Stent in the Treatment of Coronary Artery Lesions (NEVO RES-I)

24 de outubro de 2012 atualizado por: Cordis Corporation

A Randomized, Multi-Center, Single-Blind Comparison of the Conor Cobalt Chromium Reservoir Based Stent With Sirolimus Elution Versus the TAXUS Liberte Paclitaxel-eluting Coronary Stent System in De Novo Native Coronary Artery Lesions

The purpose of this study is to evaluate the safety and effectiveness of the Conor Sirolimus-eluting Coronary Stent System in the treatment of coronary artery disease (a single atherosclerotic lesion) in native coronary arteries. The study will evaluate the outcomes of a new drug-eluting stent compared to an approved drug-eluting stent.

While Cordis made a business decision to no longer pursue NEVO™ development and commercialization, the patients will be followed up as per protocol. This includes performing all protocol required follow-up visits and the collection and reporting of all safety information.

Visão geral do estudo

Descrição detalhada

Restenosis remains a frequent cause of late failure following successful coronary angioplasty occurring in an estimated 20-40% of procedures performed. Coronary stents provide mechanical scaffolding that helps reduce restenosis by limiting the extent of elastic recoil and late vascular remodeling. Despite improvements over balloon angioplasty alone, restenosis following coronary stenting procedures has been cited to occur in 20-40% of cases and is primarily a result of neointimal hyperplasia. Thus, stents which are capable of delivering drugs to limit neointimal hyperplasia, in addition to providing mechanical support at the area of the lesion, have been developed to further limit the extent of restenosis following coronary stenting. There are several pharmacologic agents approved for use with drug-eluting stents.Two drugs have been widely studied in controlled clinical trials and real-world patient populations, sirolimus and paclitaxel.

This study will evaluate a new sirolimus-eluting cobalt chromium coronary stent system compared to an approved paclitaxel-eluting coronary stent system in the treatment of single de novo coronary lesions in native coronary arteries. Subjects meeting qualification will be randomized in a 1:1 fashion to treatment with the Conor sirolimus-eluting coronary stent or to treatment with an approved paclitaxel-eluting coronary stent. All subjects will undergo angiographic follow-up at six months and complete clinical follow-up for a period of five years.

Tipo de estudo

Intervencional

Inscrição (Real)

394

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Sao Paulo, Brasil, 04012-909
        • Instituto Dante Pazzanese de Cardiologia
    • Auckland
      • Epsom, Auckland, Nova Zelândia
        • Mercy Angiography Unit

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • 18 years of age or older
  • Eligible for percutaneous coronary intervention and coronary artery bypass graft surgery.
  • Diagnosis of stable or unstable angina or silent ischemia
  • Left ventricular ejection fraction >30%
  • The subject requires treatment of a single de novo lesion in a native coronary artery.
  • Lesion to be treated is less than or equal to 28 mm in length in a vessel that is 2.5-3.5mm diameter.
  • The target lesion diameter stenosis is >50% and <100% by visual estimate.
  • The target lesion is a minimum of 10 mm distance from any previously treated segment of the target vessel.
  • The subject understands the study requirements, is willing to comply with all study procedures and has provided written informed consent.

Exclusion Criteria:

  • The subject has undergone coronary revascularization to any vessel within 30 days.
  • The subject has undergone target vessel revascularization within 6 months.
  • Treatment of more than one qualifying lesion is required at the time of enrollment, or is planned within 30 days following enrollment.
  • The subject has known sensitivity to sirolimus, paclitaxel, the polymeric matrices, stainless steel or cobalt chromium.
  • There is planned treatment of the target lesion with any device other than the pre-dilatation balloon angioplasty catheter.
  • The subject had a myocardial infarction within 72 hours, or presents with CK elevation > 2 times upper limit normal associated with elevated CK-MB.
  • The subject is in cardiogenic shock.
  • The subject had a cerebrovascular accident within the past 6 months.
  • The subject has acute or chronic renal dysfunction (defined as creatinine >2.0 mg/dl).
  • The subject has a contraindication to aspirin or clopidogrel.
  • The subject has thrombocytopenia (platelet count < 100,000/mm3.
  • The subject has had active gastrointestinal bleeding within the past 3 months.
  • The subject has a known bleeding or hypercoagulable disorder.
  • The subject has had prior anaphylactoid reaction to contrast agents or has contrast sensitivity that cannot be controlled with pre-medication.
  • The subject is currently taking immunosuppressant therapy.
  • The subject is currently, or has been treated wtih either Rapamune or paclitaxel within 12 months of the procedure.
  • The subject is a female with a positive pregnancy test or is lactating.
  • The subject has an active infection.
  • The subject has co-morbidities that could interfere wtih completion of study procedures, or life expectancy less than 24 months.
  • The subject is participating in another investigational drug or device trial that has not completed the primary endpoint or would interfere with the endpoints of this study.

Angiographic Exclusion Criteria

  • Left main disease >50% diameter stenosis.
  • The target lesion is ostial.
  • The target lesion or target vessel are severely calcified.
  • The target lesion involves a bifurcation with diseased branch vessel greater than or equal to 2.0 mm that would require intervention or protection.
  • The target lesion has TIMI o or TIMI I flow.
  • Angiographic evidence of thrombus.
  • The target vessel has had prior stent placement.
  • The patient has had prior coronary brachytherapy.
  • There is angiographic restenosis of any previously treated segment of the target vessel, or atherosclerotic area wtih >50% diameter stenosis outside of the target lesion.
  • The subject has undergone prior CABG.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Investigational arm
Subjects randomized to treatment with the NEVO™ Sirolimus-eluting Coronary Stent System.
Intervention will consist of percutaneous coronary intervention for treatment of a single coronary lesion using standard coronary intervention techniques. Intervention in this arm will include treatment with the Conor Cobalt Chromium Sirolimus-eluting Coronary Stent System. Subjects assigned to the IVUS sub-study population will undergo intravascular ultrasound evaluation immediately post-stenting.
Comparador Ativo: Control Arm
Subjects randomized to treatment with the TAXUS Liberte Paclitaxel-eluting Coronary Stent System.
Intervention will consist of percutaneous coronary intervention for treatment of a single coronary lesion using standard coronary intervention techniques. Intervention in this arm will include treatment with the TAXUS Liberte Paclitaxel-eluting Coronary Stent System. Subjects assigned to the IVUS sub-study population will undergo intravascular ultrasound evaluation immediately post-stenting.
Outros nomes:
  • Taxus Liberte Paclitaxel-eluting Coronary Stent System

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
Angiographic endpoint of in-stent late lumen loss as measured by QCA.
Prazo: 6 months
6 months

Medidas de resultados secundários

Medida de resultado
Prazo
Target Lesion Failure defined as cardiac death that cannot be clearly attributed to a non-cardiac event or non-target vessel, target vessel related myocardial infarction or clinically driven target lesion revascularization.
Prazo: hospital discharge, 30 days, 6 months and annually through five years.
hospital discharge, 30 days, 6 months and annually through five years.
Target Vessel Failure defined as any myocardial infarction or cardiac death that cannot be attributed to a non-target vessel or any target vessel revascularization.
Prazo: Hospital discharge, 30 days, 6 months and annually through five years
Hospital discharge, 30 days, 6 months and annually through five years
Major Adverse Cardiac Events defined as an adjudicated composite of death, emergent coronary artery bypass graft surgery, target lesion revascularization, or new myocardial infarction.
Prazo: Hospital discharge, 30 days, 6 months and annually through five years
Hospital discharge, 30 days, 6 months and annually through five years
Incidence of stent thrombosis
Prazo: Hospital discharge, 30 days, 6 months and annually through five years
Hospital discharge, 30 days, 6 months and annually through five years
Incidence of target lesion revascularization and target vessel revascularization.
Prazo: Hospital discharge, 30 days, 6 months and annually through five years
Hospital discharge, 30 days, 6 months and annually through five years
Device Success
Prazo: Procedural
Procedural
Lesion success
Prazo: Procedural
Procedural
Procedure Success
Prazo: Hospital Discharge
Hospital Discharge
Angiographic in-stent and in-segment binary restenosis.
Prazo: 6 months
6 months
In-stent minimum lumen diameter
Prazo: 6 months
6 months
Percent volume obstruction of the stent by intravascular ultrasound evaluation
Prazo: 6 months
6 months
Patient reported outcomes as measured by three standardized quality of life surveys.
Prazo: Baseline, 30 days, 6 months and 12 months
Baseline, 30 days, 6 months and 12 months

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Colaboradores

Investigadores

  • Investigador principal: John Ormiston, MB ChM, Mercy Angiography Unit
  • Investigador principal: Alexandre Abizaid, MD. PhD, Instituto Dante Pazzanese de Cardiologia

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Publicações Gerais

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de março de 2008

Conclusão Primária (Real)

1 de maio de 2009

Conclusão do estudo (Real)

1 de outubro de 2012

Datas de inscrição no estudo

Enviado pela primeira vez

17 de janeiro de 2008

Enviado pela primeira vez que atendeu aos critérios de CQ

31 de janeiro de 2008

Primeira postagem (Estimativa)

1 de fevereiro de 2008

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

25 de outubro de 2012

Última atualização enviada que atendeu aos critérios de controle de qualidade

24 de outubro de 2012

Última verificação

1 de outubro de 2012

Mais Informações

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em NEVO™ Sirolimus-eluting Coronary Stent System

3
Se inscrever