Surgical Outcomes Using Variable Rod Diameters in the Treatment of Idiopathic Scoliosis
Обзор исследования
Статус
Статус
Условия
Условия
Вмешательство/лечение
Вмешательство/лечение
Подробное описание
For the correction of Juvenile and Adolescent idiopathic scoliosis, companies offer and surgeons use varying rod sizes not based on scientific evidence, but because of personal preference, availability and company loyalty. To date there has been no literature evaluating the benefit or harm of one rod size versus the other. Our dual-arm prospective study will evaluate the amount of radiographic correction obtained using the 5.5mm versus the 6.35mm stainless steel instrumentation rods. These are both standard rods used in the community for this particular procedure, thus no additional risk exists for the patient. The results of this study will help guide surgeons in their decision making process when faced with the multitude of options offered by implant manufactures.
Comparison(s): 5.5mm stainless steel spinal rod versus 6.35mm stainless steel spinal rod for correction of juvenile and idiopathic scoliosis curves.
Тип исследования
Тип исследования
Регистрация (Действительный)
Регистрация
Фаза
Фаза
- Фаза 4
Контакты и местонахождение
Места учебы
-
-
California
-
Los Angeles, California, Соединенные Штаты, 90020
- Shriners Hospitals for Children - Los Angeles
-
-
Критерии участия
Критерии приемлемости
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Diagnosis of Juvenile or Adolescent Idiopathic Scoliosis
- Anticipated spinal fusion surgery
Exclusion Criteria:
- Individuals younger than 11 years and older than 18 years
- Individuals with scoliosis carrying additional diagnoses of illness.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Нет (открытая этикетка)
Количество рук
Оружие и интервенции
Группа участников / АрмияГруппа участников / Армия |
Вмешательство/лечениеВмешательство/лечение |
|---|---|
|
Активный компаратор: 1
Subjects in this arm will receive the 5.5mm stainless steel instrumentation rod.
|
Posterior spinal fusion using a 5.5 or 6.35 size rod
|
|
Активный компаратор: 2
Subjects in this arm will receive a 6.35mm stainless steel instrumentation rod.
|
Posterior spinal fusion using a 5.5 or 6.35 size rod
|
Что измеряет исследование?
Первичные показатели результатов
Первичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
Radiographic measurements of curve angles and balance.
Временное ограничение: Pre-operatively, 6 wks post-op, 1 & 2 year post-op.
|
Pre-operatively, 6 wks post-op, 1 & 2 year post-op.
|
Вторичные показатели результатов
Вторичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
Scoliosis Research Society-30 (SRS-30) questionnaire
Временное ограничение: Pre-operatively, 6 wks post-op, 1 & 2 year post-op.
|
Pre-operatively, 6 wks post-op, 1 & 2 year post-op.
|
Соавторы и исследователи
Спонсор
Спонсор
Следователи
Следователи
- Директор по исследованиям: Norman Otsuka, MD, Shriners Hospitals for Children - Los Angeles
- Главный следователь: Richard Bowen, MD, Shriners Hospitals for Children - Los Angeles
Даты записи исследования
Изучение основных дат
Начало исследования
Начало исследования
Первичное завершение (Действительный)
Первичное завершение
Завершение исследования (Действительный)
Завершение исследования
Даты регистрации исследования
Первый отправленный
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Первый опубликованный
Обновления учебных записей
Последнее опубликованное обновление (Оценивать)
Последнее опубликованное обновление
Последнее отправленное обновление, отвечающее критериям контроля качества
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
Другие идентификационные номера исследования
- SHCLA-0123
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .