3D Transthoracic Echocardiographic Evaluation on Tricuspid Regurgitation Progression and Clinical Outcomes in Patients With Cardiac Implantable Electronic Device (3DECHO-TR)
The goal of this observational study is to learn about the development and worsening of tricuspid regurgitation (TR) in patients who have cardiac implantable electronic devices (CIEDs).
The main objective is to compare left bundle branch area pacing (LBBaP) and leadless pacemakers against conventional pacemakers in terms of TR exacerbation.
Participants with these devices will have their retrospective and prospective clinical data analyzed and will undergo 3D transthoracic echocardiography to identify the exact mechanical causes of TR.
Обзор исследования
Статус
Статус
Условия
Условия
Вмешательство/лечение
Вмешательство/лечение
Подробное описание
As the use of cardiac implantable electronic devices(CIED) increases, CIED-related tricuspid regurgitation (CIED-related TR) is emerging as a critical clinical issue. CIED-related TR is one of the most common causes of primary TR, with a reported incidence ranging from approximately 10% to 30%. Numerous studies have confirmed that the severity of CIED-related TR is closely associated with poor prognosis.
This condition is particularly noteworthy because, unlike secondary TR, it possesses mechanical causes that are potentially intervenable. However, most studies published to date have reported results based on 2D echocardiography, which often leads to ambiguity in identifying the exact mechanisms behind the exacerbation of tricuspid regurgitation. Furthermore, there is a significant lack of data regarding TR associated with more recently introduced procedures, such as left bundle branch area pacing (LBBaP) and leadless pacemakers. Therefore, this study aims to perform 3D transthoracic echocardiography on patients with lead-based CIEDs and leadless pacemakers to comparatively analyze LBBaP and leadless pacemaker patients against conventional pacemaker patients in terms of TR exacerbation. By combining retrospective and prospective clinical data, this research will analyze the incidence and clinical impact of these conditions.
Тип исследования
Тип исследования
Регистрация (Оцененный)
Регистрация
Контакты и местонахождение
Контакты исследования
Контакты исследования
- Имя: Juwon Kim
- Номер телефона: 82+ 2-3410-3419
- Электронная почта: abcd186a@naver.com
Места учебы
-
-
Seoul
-
Seoul, Seoul, Южная Корея, 06351
- Рекрутинг
- Samsung Medical Center
-
Контакт:
- Juwon Kim
- Номер телефона: 82+ 2-3410-3419
- Электронная почта: abcd186a@naver.com
-
-
Критерии участия
Критерии приемлемости
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Метод выборки
Исследуемая популяция
Описание
Inclusion Criteria:
- Aged 19 years or older.
- Patients who are at least one year post-implantation of one of the following Cardiac Implantable Electronic Devices (CIEDs):
A. Permanent Pacemaker (PPM) B. Implantable Cardioverter-Defibrillator (ICD) C. Leadless Pacemaker
- Patients who underwent the implantation procedure on or after January 2022.
- Voluntary informed consent provided by the patient or their legal representative for the review of medical records and study-related data throughout the entire study period.
Exclusion Criteria:
- Patients with lead-based CIEDs whose leads do not cross the tricuspid annulus or those with two or more leads crossing the annulus.
- Patients whose baseline degree of tricuspid regurgitation (TR) cannot be assessed due to the absence of transthoracic echocardiography (TTE) performed within three months of the procedure.
- Patients with a history of ventricular lead extraction.
- Patients who have undergone tricuspid valve replacement surgery.
- Individuals who refuse active medical treatment.
Учебный план
Как устроено исследование?
Детали дизайна
Количество групп / когорт
Когорты и вмешательства
Группа / когортаГруппа / когорта |
Вмешательство/лечениеВмешательство/лечение |
|---|---|
|
A patient one year after receiving a cardiac implantable electronic device
Subjects aged 19 years or older who underwent de novo implantation of a leadless PPM or a cardiac implantable electronic device (PPM or ICD) at Samsung Medical Center between 2022 and 2025, and are at least one year post-implantation
|
The incidence and mechanisms of worsening tricuspid regurgitation are identified through three-dimensional echocardiography, and the resulting structural and functional changes in the heart are evaluated.
|
Что измеряет исследование?
Первичные показатели результатов
Первичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
hospitalization due to heart failure
Временное ограничение: From the date of CIED implantation until the date of the first heart failure hospitalization or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first heart failure hospitalization or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
Вторичные показатели результатов
Вторичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
incidence of CIED related, associated TR
Временное ограничение: Assessed at the time of the study 3D transthoracic echocardiography, performed at least 1 year after CIED implantation, up to 6 years after implantation.
|
Assessed at the time of the study 3D transthoracic echocardiography, performed at least 1 year after CIED implantation, up to 6 years after implantation.
|
|
re-admission due to any cause
Временное ограничение: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
|
Tricuspid valve intervention
Временное ограничение: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
|
transvenous lead extraction or reposition
Временное ограничение: From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
From the date of CIED implantation until the date of the first event or the date of the study 3D transthoracic echocardiography, whichever occurred first, assessed up to 6 years.
|
Соавторы и исследователи
Спонсор
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Начало исследования
Первичное завершение (Оцененный)
Первичное завершение
Завершение исследования (Оцененный)
Завершение исследования
Даты регистрации исследования
Первый отправленный
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Первый опубликованный
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее опубликованное обновление
Последнее отправленное обновление, отвечающее критериям контроля качества
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
Другие идентификационные номера исследования
- SMC 2026-01-010
- KCT0011605 (Другой идентификатор: Korea National Institute of Health)
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .