Comparison of the Effect of Lung-protective Ventilation on Optic Nerve Sheath Diameter in Obese and Non-obese Patients
Comparison of the Effect of Recruitment Maneuver and Individualized Positive End-expiratory Pressure on Optic Nerve Sheath Diameter in Obese and Non-obese Patients Undergoing Laparoscopic Surgery
The gol of this prospective observational study is to evaluate the effect of recruitment maneuvers-employed as part of an intraoperative lung-protective ventilation strategy-and individualized positive end-expiratory pressure (PEEP) on intracranial pressure, as assessed by measuring the optic nerve sheath diameter, in both obese and non-obese patients undergoing laparoscopic surgery.
Обзор исследования
Статус
Статус
Условия
Условия
Вмешательство/лечение
Вмешательство/лечение
Подробное описание
Laparoscopy is widely used due to its advantages, such as less blood loss, reduced postoperative pain, and faster recovery. However, pneumoperitoneum increases thoracoabdominal pressure, which decreases venous drainage from the brain and increases cerebral blood flow and intracranial pressure (ICP). The optic nerve sheath diameter (ONSD) measurement via ultrasound is a non-invasive and reliable method for assessing ICP.
The prevalence of obesity has increased substantially over recent decades, accompanied by a growing number of obese patients undergoing laparoscopic surgery. Obesity is associated with increased intra-abdominal pressure, which may contribute to an increase in ONSD. Furthermore, the additional rise in intra-abdominal pressure induced by pneumoperitoneum may exacerbate these effects, potentially placing obese patients at greater risk of alterations in cerebral haemodynamics during laparoscopic procedures.
Atelectasis occurs in roughly 90% of all patients undergoing general anaesthesia and can persist for weeks after operation. Intraoperative lung-protective ventilation has been recommended to reduce postoperative pulmonary complications after abdominal and/or laparoscopic surgery and also in obese patients. Decreasing compliance caused by surgical/ anaesthesia factors (i.e. pneumoperitoneum, positioning, and circuit disconnect) should be treated by appropriate interventions. Individualised PEEP and alveolar recruitment manoeuvres can prevent and reverse alveolar collapse, respectively.
However, the effects of these interventions on cerebral haemodynamics, particularly ICP as assessed indirectly by ONSD measurement, remain insufficiently understood in obese and non-obese patients undergoing laparoscopic surgery.
The gol of this prospective observational study is to evaluate the effect of recruitment maneuvers and individualized PEEP- as part of intraoperative lung-protective ventilation strategy- on intracranial pressure, as assessed by measuring the optic nerve sheath diameter (ONSD), in both obese and non-obese patients undergoing laparoscopic surgery.
Тип исследования
Тип исследования
Регистрация (Оцененный)
Регистрация
Фаза
Фаза
- Непригодный
Контакты и местонахождение
Контакты исследования
Контакты исследования
- Имя: Gulay Erdogan Kayhan, Prof. Dr.
- Номер телефона: 905332560011
- Электронная почта: drgulayer@yahoo.com
Учебное резервное копирование контактов
- Имя: Muhammed Alpaslan Uludag, Research Assistant, MD
- Электронная почта: muho.78@live.com
Критерии участия
Критерии приемлемости
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- Patients over 25 years of age
- American Soc,ety of Anesthesiology (ASA) status I-III
- Scheduled to undergo laparoscopic abdominal surgery
- With an expected pneumoperitoneum duration of ≥1 hour
Exclusion Criteria:
- Patients with ocular disease
- Patients who have undergone cranial or ocular surgery
- Patients with a history of laparotomy
- Individuals with bullous lung disease
- Patients with uncontrolled chronic obstructive lung disease
- Patients with hemodynamic instability or decompensated heart failure
- Patients who require conversion to an open surgical procedure for any reason
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Диагностика
- Распределение: Нерандомизированный
- Интервенционная модель: Параллельное назначение
- Маскировка: Одинокий
Количество рук
Оружие и интервенции
Группа участников / АрмияГруппа участников / Армия |
Вмешательство/лечениеВмешательство/лечение |
|---|---|
|
Другой: Group O
Obese patients with BMI ≥ 30 kg/m² |
Following intubation and desufflation, an incremental alveolar recruitment maneuver (ARM) will be performed, in which the driving pressure is kept constant while the PEEP value is increased in a stepwise manner. The ARM will be performed in pressure control mode, maintaining pressure at a steady driving pressure with increments in PEEP until a peak pressure is achieved (35-40 cmH2) with a preestablished maximum PEEP. This will be maintained long enough to reopen the alveoli (5---10 breaths), and then pressure is reduced in a stepwise manner until the ideal PEEP is achieved (this being the PEEP level that produces the best Cdyn at the lowest driving pressure for a particular tidal volume setting) ONSD will be measured at a standard level of 3 mm behind using a lineer ultrasound transducer. The measurements will be performed by an anesthesiologist experienced in ONSD measurement. The eyes will be covered with drapes; subsequently, using an ultrasound-compatible gel, measurements of both of the patient's eyes will be taken in a transverse and a sagittal plane. The mean of these measurements will then be calculated to determine the ONSD value. |
|
Другой: Group N
Non-obese patients |
Following intubation and desufflation, an incremental alveolar recruitment maneuver (ARM) will be performed, in which the driving pressure is kept constant while the PEEP value is increased in a stepwise manner. The ARM will be performed in pressure control mode, maintaining pressure at a steady driving pressure with increments in PEEP until a peak pressure is achieved (35-40 cmH2) with a preestablished maximum PEEP. This will be maintained long enough to reopen the alveoli (5---10 breaths), and then pressure is reduced in a stepwise manner until the ideal PEEP is achieved (this being the PEEP level that produces the best Cdyn at the lowest driving pressure for a particular tidal volume setting) ONSD will be measured at a standard level of 3 mm behind using a lineer ultrasound transducer. The measurements will be performed by an anesthesiologist experienced in ONSD measurement. The eyes will be covered with drapes; subsequently, using an ultrasound-compatible gel, measurements of both of the patient's eyes will be taken in a transverse and a sagittal plane. The mean of these measurements will then be calculated to determine the ONSD value. |
Что измеряет исследование?
Первичные показатели результатов
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Optic nerve sheath diameter (ONSD)
Временное ограничение: Perioperative/Periprocedural (t0-after anesthesia induction and entubation)
|
Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound |
Perioperative/Periprocedural (t0-after anesthesia induction and entubation)
|
|
Optic nerve sheath diameter (ONSD)
Временное ограничение: Perioperative/Periprocedural (t1- following the recruitment maneuver and the adjustment of the individualized PEEP value)
|
Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound |
Perioperative/Periprocedural (t1- following the recruitment maneuver and the adjustment of the individualized PEEP value)
|
|
Optic nerve sheath diameter (ONSD)
Временное ограничение: Perioperative/Periprocedural (t2- at the 30th minute of pneumoperitoneum)
|
Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound |
Perioperative/Periprocedural (t2- at the 30th minute of pneumoperitoneum)
|
|
Optic nerve sheath diameter (ONSD)
Временное ограничение: Perioperative/Periprocedural (t3 - after desufflation)
|
Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound |
Perioperative/Periprocedural (t3 - after desufflation)
|
|
Optic nerve sheath diameter (ONSD)
Временное ограничение: Perioperative/Periprocedural (t4- following a subsequent recruitment maneuver)
|
Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound |
Perioperative/Periprocedural (t4- following a subsequent recruitment maneuver)
|
|
Optic nerve sheath diameter (ONSD)
Временное ограничение: Perioperative/Periprocedural (t5- at the 30th minute in the recovery room)
|
Perioperative ONSD will be measured 3 mm behind the eye globe with ultrasound |
Perioperative/Periprocedural (t5- at the 30th minute in the recovery room)
|
Вторичные показатели результатов
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
MAP
Временное ограничение: Perioperative (Noninvasive mean arterial pressure will be recorded at the times when ONSD measurement is performed)
|
Noninvasive mean arterial pressure (mmHg) |
Perioperative (Noninvasive mean arterial pressure will be recorded at the times when ONSD measurement is performed)
|
|
HR
Временное ограничение: Perioperative (Heart rate will be recorded at the times when ONSD measurement is performed)
|
Heart rate (beat/min) |
Perioperative (Heart rate will be recorded at the times when ONSD measurement is performed)
|
|
etCO2
Временное ограничение: Perioperative (End-tidal carbon dioxide levels will be recorded at the times when ONSD measurement is performed)
|
End-tidal carbon dioxide levels (mmHg) |
Perioperative (End-tidal carbon dioxide levels will be recorded at the times when ONSD measurement is performed)
|
Другие показатели результатов
Другие показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Airway pressures during mechanical ventilation
Временное ограничение: Perioperative (Ppeak, Pplato, Driving pressure (∆P), PEEP levels will be recorded at the times when ONSD measurement is performed)
|
Ppeak, Pplato, Driving pressure (∆P), PEEP levels (cmH20) will be recorded from the sama ventilation monitor screen |
Perioperative (Ppeak, Pplato, Driving pressure (∆P), PEEP levels will be recorded at the times when ONSD measurement is performed)
|
|
Postoperative complications
Временное ограничение: PONV will be questioned at the 24th hours
|
Postoperative nause and vomiting (PONV) |
PONV will be questioned at the 24th hours
|
|
Postoperative complications
Временное ограничение: Headache will be questioned at the 24th hours
|
Headache |
Headache will be questioned at the 24th hours
|
|
Postoperative complications
Временное ограничение: Visual disturbance will be questioned at the 24th hours
|
Visual disturbance |
Visual disturbance will be questioned at the 24th hours
|
Соавторы и исследователи
Спонсор
Спонсор
Публикации и полезные ссылки
Даты записи исследования
Изучение основных дат
Начало исследования (Оцененный)
Начало исследования
Первичное завершение (Оцененный)
Первичное завершение
Завершение исследования (Оцененный)
Завершение исследования
Даты регистрации исследования
Первый отправленный
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Первый опубликованный
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее опубликованное обновление
Последнее отправленное обновление, отвечающее критериям контроля качества
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
Другие идентификационные номера исследования
- E-25403353-050.04-260108454
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .