Gluteus Maximus Transfer for Hip Abductor Insufficiency Following Total Hip Arthroplasty
Clinical and Functional Outcomes of Gluteus Maximus Transfer for the Management of Hip Abductor Insufficiency Following Total Hip Arthroplasty: A Clinical Study
Hip abductor insufficiency is a challenging complication following total hip arthroplasty (THA). It may result from damage to the abductor muscles or tendons, particularly the gluteus medius and minimus, and can lead to persistent hip pain, muscle weakness, a positive Trendelenburg sign, and impaired walking ability.
Gluteus maximus transfer is a surgical procedure used to restore the function of the hip abductor mechanism in patients with severe abductor insufficiency. This study aims to evaluate the clinical and functional outcomes of gluteus maximus transfer in patients who develop abductor insufficiency following total hip arthroplasty.
The study will assess postoperative improvements in hip function, abductor strength, gait, pain, and patient-reported functional outcomes, as well as the occurrence of postoperative complications. The hypothesis is that gluteus maximus transfer can provide meaningful functional improvement in appropriately selected patients with persistent abductor insufficiency following total hip arthroplasty.
Обзор исследования
Статус
Статус
Условия
Условия
Вмешательство/лечение
Вмешательство/лечение
Тип исследования
Тип исследования
Регистрация (Оцененный)
Регистрация
Фаза
Фаза
- Непригодный
Критерии участия
Критерии приемлемости
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
**Inclusion Criteria**
- Adult patients aged 18 years or older.
- Patients who underwent primary or revision total hip arthroplasty.
- Patients with symptomatic hip abductor insufficiency following total hip arthroplasty.
- Clinical evidence of abductor mechanism deficiency, including abductor weakness, positive Trendelenburg sign, or gait disturbance.
- Patients with irreparable or functionally deficient hip abductor mechanism considered suitable for gluteus maximus transfer.
- Availability of preoperative and postoperative clinical and functional assessment data.
**Exclusion Criteria**
- Active periprosthetic joint infection at the time of the planned procedure.
- Neurological disorders significantly affecting hip abductor function or gait.
- Severe gluteus maximus muscle dysfunction or insufficiency that precludes transfer.
- Severe medical comorbidities contraindicating surgery.
- Inadequate clinical follow-up or missing essential outcome data.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Количество рук
Оружие и интервенции
Группа участников / АрмияГруппа участников / Армия |
Вмешательство/лечениеВмешательство/лечение |
|---|---|
|
Экспериментальный: Gluteus Maximus Transfer
Patients with hip abductor insufficiency following total hip arthroplasty undergoing gluteus maximus transfer for reconstruction of the deficient hip abductor mechanism. |
Surgical transfer of the gluteus maximus muscle to reconstruct the deficient hip abductor mechanism in patients with persistent abductor insufficiency following total hip arthroplasty. The procedure aims to improve hip abductor function, pelvic stability, gait, and overall functional outcomes. |
Что измеряет исследование?
Первичные показатели результатов
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Change in Hip Abductor Muscle Strength
Временное ограничение: Preoperative assessment and 12 months postoperatively.
|
Assessment of hip abductor muscle strength before and after gluteus maximus transfer using manual muscle testing according to the Medical Research Council (MRC) grading scale (0-5). |
Preoperative assessment and 12 months postoperatively.
|
Вторичные показатели результатов
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Functional Outcome - Harris Hip Score
Временное ограничение: preoperative baseline to 12 months postoperatively
|
Change in Harris Hip Score from preoperative baseline to 12 months postoperatively to assess hip pain and function. |
preoperative baseline to 12 months postoperatively
|
|
Trendelenburg Sign
Временное ограничение: preoperative and 12 month postoperative
|
Assessment of the presence or absence of Trendelenburg sign during clinical examination before and 12 month after surgery. |
preoperative and 12 month postoperative
|
|
Pain Assessment
Временное ограничение: preoperative and 12 months postoperative
|
Change in hip pain intensity measured using the Visual Analog Scale (VAS). |
preoperative and 12 months postoperative
|
|
Postoperative Complications
Временное ограничение: during the period of follow up 12 months postoperative
|
Documentation of postoperative complications, including persistent abductor weakness, infection, dislocation, wound complications, and revision surgery. |
during the period of follow up 12 months postoperative
|
Соавторы и исследователи
Спонсор
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Оцененный)
Начало исследования
Первичное завершение (Оцененный)
Первичное завершение
Завершение исследования (Оцененный)
Завершение исследования
Даты регистрации исследования
Первый отправленный
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Первый опубликованный
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее опубликованное обновление
Последнее отправленное обновление, отвечающее критериям контроля качества
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Другие идентификационные номера исследования
Другие идентификационные номера исследования
- asy453789
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .