肌筋膜释放技术对短腘绳肌受试者呼吸参数的影响
肌筋膜释放技术对短腘绳肌受试者呼吸功能、呼吸肌力量和耐力的影响
The aim of this study was to investigate the effect of myofascial release technique on rib cage mobility, respiratory function, respiratory muscle strength and endurance in patients with hamstring muscle shortness.
研究概览
详细说明
Hamstring flexibility is important to maintain activities such as walking and running in daily life. Hamstring muscle shortness, commonly seen in the community, is a risk factor for many musculoskeletal pathologies. Clinical observations have shown that the shortness of the Hamstring muscle causes spinal malalignment. This deterioration of the spine alignment may adversely affect the rib cage expansion. Moreover, considering that the optimal length of the muscles provides optimal contraction, it was found that the spinal malalignment adversely affected the effective contraction of the diaphragm by changing the position of diaphragm. A different view is that, because the fascia functions as a single tissue surrounding the entire body, a restriction in the hamstring muscle can also cause a restriction in distal muscles such as diaphragm through the fascia.
There are many treatment methods used to increase the flexibility of the hamstring muscle. One of these methods is the myofascial release technique. In this technique, which targets both muscle and fascia, applying light and prolonged pressure provides the myo-fascial complex to reach its optimal length, resulting in the optimal function of the muscle. In our best knowledge, no study has evaluated the effect of myofascial release technique on respiratory parameters in patients with hamstring muscle shortness.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Istanbul、土耳其(türkiye)
- Bezmialem Vakıf University
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- more than 15 degrees knee flexion angle during popliteal angle test,
- no generalized joint laxity according to Beighton Criteria, and
- no musculoskeletal problems of lower extremities.
Exclusion Criteria:
- history of lower extremity and/or axial skeletal fracture;
- recent muscle, tendon injury in lower extremity;
- history of lumbal disc herniation, arthritic and/or inflammatory disease;
- obesity, diabetes and/or metabolic syndrome;
- history of surgery in the last month,
- using muscle relaxant medication in the last month;
- received manual therapy in the last month
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:双倍的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
假比较器:Sham-Ultrasound
Intervention will include one session sham-ultrasound application to both lower extremities of participant. The total time will be 15 minutes. |
Sham-ultrasound will be applied to back of legs and thighs in both extremities without pressure and all parameters of the ultrasound device except the timer will be closed. |
|
实验性的:Myofascial Release Technique+Sham-Ultrasound
In addition to one session sham-ultrasound, the intervention will include one session myofascial release technique to both lower extremities of participant. The total time will be 30 minutes. |
Sham-ultrasound will be applied to back of legs and thighs in both extremities without pressure and all parameters of the ultrasound device except the timer will be closed. Myofascial release technique will bi applied bottom of the feet, back of the legs and hamstrings in both extremities. The practitioner will decide how long she should stay in a region according to the feeling of releasing in the tissue. The technique will be applied to a region at least 3 times. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Change from baseline subcostal region chest expansion test at 60 minutes
大体时间:60 minutes
|
Chest Circumference Measurement |
60 minutes
|
|
Change from baseline xiphoid region chest expansion test at 60 minutes
大体时间:60 minutes
|
Chest Circumference Measurement |
60 minutes
|
|
Change from baseline axillary region chest expansion test at 60 minutes
大体时间:60 minutes
|
Chest Circumference Measurement |
60 minutes
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Change from baseline maximum inspiratory pressure (MIP) at 60 minutes
大体时间:60 minutes
|
Respiratory Muscle Strength Test |
60 minutes
|
|
Change from baseline maximum expiratory pressure (MEP) at 60 minutes
大体时间:60 minutes
|
Respiratory Muscle Strength Test |
60 minutes
|
|
Change from baseline Forced Vital Capacity (FVC) at 60 minutes
大体时间:60 minutes
|
Respiratory Function Test |
60 minutes
|
|
Change from baseline Forced Expiratory Volume in 1 second (FEV1) at 60 minutes
大体时间:60 minutes
|
Respiratory Function Test |
60 minutes
|
|
Change from baseline FEV1/FVC at 60 minutes
大体时间:60 minutes
|
Respiratory Function Test |
60 minutes
|
|
Change from baseline Peak Expiratory Flow (PEF) at 60 minutes
大体时间:60 minutes
|
Respiratory Function Test |
60 minutes
|
|
Change from baseline Forced Expiratory Flow 25-75% at 60 minutes
大体时间:60 minutes
|
Respiratory Function Test |
60 minutes
|
合作者和调查者
调查人员
- 学习椅:Betül Çınar、Bezmialem Vakif University
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.