此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

使用动态立体 X 射线量化 Transtibial 截肢患者残肢的骨骼和皮肤运动

2026年11月12日 更新者:VA Office of Research and Development

使用动态立体 X 射线量化 Transtibial 截肢患者残余肢体接口中的骨骼和皮肤运动

Individuals with lower extremity amputation are often challenged by complications that arise from poor prosthetic fit, including movement of the residual limb in the socket, known as pistoning. Pistoning can lead to gait instability, skin problems, and pain. Different prosthetic suspension systems have been developed to decrease this motion, including elevated vacuum suspension, which utilizes a pump to draw air from the socket. However, scientific analyses to understand the movement between the limb and socket have yet to be performed with a high level of accuracy. This study will use a state-of-the art imaging technique, known as dynamic stereo x-ray, to quantify the 3D movement of the residual limb in the socket. It is hypothesized that dynamic stereo x-ray will be a sensitive method to measure differences in residual limb movement between 2 different socket suspension techniques: suction and elevated vacuum suspension. This information is critical for advancing prosthetic treatments to reduce secondary conditions and degenerative changes that result from poor prosthetic fit.

研究概览

详细说明

Individuals with lower extremity amputation (LEA) often experience relative motion between their residual limb and the prosthetic socket, such as vertical translation and axial rotation, which can cause inefficient dynamic load transmission from the distal prosthetic components to the residual limb. This can lead to significant secondary consequences, such as pain, gait deviations, and discomfort that limit mobility and autonomy. Assessments of the relative motion between the bone and the prosthetic socket have been performed, but there is little existing data on dynamic, in vivo residual limb-socket kinematics since most investigations have been performed using non-dynamic testing protocols, static measurements, or with unvalidated surface marker-based motion capture systems. Dynamic Stereo X-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and tissue/liner deformation inside a prosthetic socket during dynamic activities.

There is a substantial gap in our understanding of the complex mechanics of the residual limb-socket interface during dynamic activities that limit the ability to improve prosthetic design. The goals for this project are to develop the analytical tools to quantify both the dynamic, in-vivo kinematics between the residual limb and socket, as well as the mechanism of residual tissue/liner deformation. In order to validate the sensitivity of this methodology to differences in socket suspension, 2 suspension systems will be evaluated: elevated vacuum and traditional suction. It is hypothesized that an efficient and highly accurate method to quantify the dynamic interaction between the residual limb and prosthetic socket will be sensitive enough to distinguish between different types of prosthetic socket suspension, which will further the biomechanical understanding of socket design. To do so, the investigators will address the following aims: (1) To optimize the DSX procedural setup for the accurate tracking of the prosthetic socket, skeletal kinematics, and tissue/liner deformation; (2) To quantify the relative motion between the residual tibia and the prosthetic socket during dynamic activities; and (3) To measure the deformation of the skin and liner in the prosthetic socket during dynamic activities.

Twenty-one participants with transtibial amputation will be fit with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested at the DSX facility. DSX will be utilized to track skeletal and skin/liner motion under both suspension techniques during 3 dynamic activities: treadmill walking at self-selected speed, fast walking (10% faster), and a step-down movement. The performance of the two suspension techniques (active EV and traditional suction) will be tested by quantifying the 3D bone movement of the residual tibia with respect to the prosthetic socket and quantifying liner and soft tissue deformation at the socket-residuum interface.

By using the analytical tools for a highly accurate, in-vivo assessment of residual limb-socket motion, vital foundational information can be provided to aid in the development of new methods and techniques to enhance prosthetic fit that have the potential to reduce secondary physical comorbidities and degenerative changes that result from complications of poor prosthetic load transmission.

研究类型

介入性

注册 (估计的)

21

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

    • New York
      • New York、New York、美国、10010-5011
        • 招聘中
        • VA NY Harbor Healthcare System, New York, NY
        • 首席研究员:
          • Jason Maikos, PhD
        • 接触:
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Unilateral transtibial amputation (any etiology)
  • At least 18 years old
  • At least 6-months post-amputation
  • Current prosthetic users (at least 6 hours/day)

Exclusion Criteria:

  • Unable to ambulate on a treadmill at low to moderate speed
  • Inability to tolerate the socket suspensions
  • Length of the residual limb prohibits socket fitting, dynamic stereo x-ray data capture, or marker placement
  • Mental impairment that impedes study compliance
  • Skin conditions (i.e. burns or poor skin coverage) as well as those with severe contractures that prevent prior prosthetic wear
  • Severe neuropathy, uncontrolled diabetes, have insensate foot, severe phantom pain, or a significant history of skin ulcers
  • Any other significant comorbidity that would interfere with the study
  • Severe circulatory problems including peripheral vascular disease and pitting edema
  • Cognitive deficits or mental health problems that would limit ability to participate fully in the study protocol
  • Women who are pregnant or who plan to become pregnant during the study

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:基础科学
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
有源比较器:Suction Suspension First

The residual limb will be imaged during dynamic activities while participants use suction suspension first, then while participants use elevated vacuum suspension. Dynamic stereo x-ray will take place 4-weeks after socket fitting.

Participants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system inactive (traditional suction). Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system active.

有源比较器:Elevated Vacuum Suspension First

The residual limb will be imaged during dynamic activities while participants use elevated vacuum suspension first, then while participants use suction suspension. Dynamic stereo x-ray will take place 4-weeks after socket fitting.

Participants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system active. Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system inactive.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Changes in dynamic residual tibia kinematics between suspension techniques
大体时间:4 weeks post socket fit

To evaluate the 6 degree of freedom kinematics of the residual limb within the socket, participants with transtibial amputation will walk on a treadmill at a self-selected speed, at a speed 10% faster than their self-selected speed, and also perform a step-down task from an 18 cm high platform. These movement tasks will be completed under 2 conditions: with the elevated suspension active and with the elevated system inactive (traditional suction). Up to 4 trials of dynamic stereo x-ray will be conducted for each task for each socket condition. For each task, dynamic stereo x-ray data will be collected and analyzed to determine underlying bone movement with respect to the socket. Six degree of freedom residual tibia rotations and translations relative to the prosthetic socket will be measured.

4 weeks post socket fit
Changes in dynamic skin deformation of the residual limb between suspension techniques
大体时间:4 weeks post socket fit

Radio-opaque markers will be placed on the residual limb in specific patterns. Participants will walk on a treadmill at a self-selected speed, at a speed 10% faster than their self-selected speed, and also perform a step-down task from an 18 cm high platform. These movement tasks will be completed under 2 conditions: with the elevated suspension active and with the elevated system inactive (traditional suction). Up to 4 trials of dynamic stereo x-ray will be conducted for each task for each socket condition. For each task, dynamic stereo x-ray data will be collected and analyzed to determine underlying skin deformation. The radio-opaque markers on the skin will be tracked during the dynamic trials, and their trajectories in the socket coordinate system will define the motion of the skin relative to the socket. Shear, defined as the change in angle between the markers, and compression, defined as the change in distance between markers and a neutral position, will be calculated.

4 weeks post socket fit

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Jason Maikos, PhD、VA NY Harbor Healthcare System, New York, NY

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2024年1月5日

初级完成 (估计的)

2027年2月28日

研究完成 (估计的)

2027年3月31日

研究注册日期

首次提交

2022年3月9日

首先提交符合 QC 标准的

2022年3月9日

首次发布 (实际的)

2022年3月18日

研究记录更新

最后更新发布 (实际的)

2026年11月16日

上次提交的符合 QC 标准的更新

2026年11月12日

最后验证

2026年4月1日

更多信息

与本研究相关的术语

其他研究编号

  • A3700-R
  • 1I01RX003700-01A2 (美国 NIH 拨款/合同)

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

是的

IPD 计划说明

De-identified individual participant data will be stored in a curated data repository that makes the data underlying scientific publications discoverable, freely usable, and citable, while promoting openly available research integrated with scholarly literature.

IPD 共享时间框架

After study completion

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅