- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT05287646
Quantificando o Movimento de Osso e Pele no Membro Residual de Indivíduos com Amputação Transtibial Usando Raio-X Estéreo Dinâmico
Quantificando o movimento do osso e da pele na interface residual do membro de indivíduos com amputação transtibial usando raio-x estéreo dinâmico
Individuals with lower extremity amputation are often challenged by complications that arise from poor prosthetic fit, including movement of the residual limb in the socket, known as pistoning. Pistoning can lead to gait instability, skin problems, and pain. Different prosthetic suspension systems have been developed to decrease this motion, including elevated vacuum suspension, which utilizes a pump to draw air from the socket. However, scientific analyses to understand the movement between the limb and socket have yet to be performed with a high level of accuracy. This study will use a state-of-the art imaging technique, known as dynamic stereo x-ray, to quantify the 3D movement of the residual limb in the socket. It is hypothesized that dynamic stereo x-ray will be a sensitive method to measure differences in residual limb movement between 2 different socket suspension techniques: suction and elevated vacuum suspension. This information is critical for advancing prosthetic treatments to reduce secondary conditions and degenerative changes that result from poor prosthetic fit.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Individuals with lower extremity amputation (LEA) often experience relative motion between their residual limb and the prosthetic socket, such as vertical translation and axial rotation, which can cause inefficient dynamic load transmission from the distal prosthetic components to the residual limb. This can lead to significant secondary consequences, such as pain, gait deviations, and discomfort that limit mobility and autonomy. Assessments of the relative motion between the bone and the prosthetic socket have been performed, but there is little existing data on dynamic, in vivo residual limb-socket kinematics since most investigations have been performed using non-dynamic testing protocols, static measurements, or with unvalidated surface marker-based motion capture systems. Dynamic Stereo X-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and tissue/liner deformation inside a prosthetic socket during dynamic activities.
There is a substantial gap in our understanding of the complex mechanics of the residual limb-socket interface during dynamic activities that limit the ability to improve prosthetic design. The goals for this project are to develop the analytical tools to quantify both the dynamic, in-vivo kinematics between the residual limb and socket, as well as the mechanism of residual tissue/liner deformation. In order to validate the sensitivity of this methodology to differences in socket suspension, 2 suspension systems will be evaluated: elevated vacuum and traditional suction. It is hypothesized that an efficient and highly accurate method to quantify the dynamic interaction between the residual limb and prosthetic socket will be sensitive enough to distinguish between different types of prosthetic socket suspension, which will further the biomechanical understanding of socket design. To do so, the investigators will address the following aims: (1) To optimize the DSX procedural setup for the accurate tracking of the prosthetic socket, skeletal kinematics, and tissue/liner deformation; (2) To quantify the relative motion between the residual tibia and the prosthetic socket during dynamic activities; and (3) To measure the deformation of the skin and liner in the prosthetic socket during dynamic activities.
Twenty-one participants with transtibial amputation will be fit with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested at the DSX facility. DSX will be utilized to track skeletal and skin/liner motion under both suspension techniques during 3 dynamic activities: treadmill walking at self-selected speed, fast walking (10% faster), and a step-down movement. The performance of the two suspension techniques (active EV and traditional suction) will be tested by quantifying the 3D bone movement of the residual tibia with respect to the prosthetic socket and quantifying liner and soft tissue deformation at the socket-residuum interface.
By using the analytical tools for a highly accurate, in-vivo assessment of residual limb-socket motion, vital foundational information can be provided to aid in the development of new methods and techniques to enhance prosthetic fit that have the potential to reduce secondary physical comorbidities and degenerative changes that result from complications of poor prosthetic load transmission.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Jason Maikos, PhD
- Número de telefone: 7482 (212) 686-7500
- E-mail: Jason.Maikos@va.gov
Estude backup de contato
- Nome: Michael J Hyre, MS
- Número de telefone: 3339 (212) 686-7500
- E-mail: michael.hyre@va.gov
Locais de estudo
-
-
New York
-
New York, New York, Estados Unidos, 10010-5011
- Recrutamento
- VA NY Harbor Healthcare System, New York, NY
-
Investigador principal:
- Jason Maikos, PhD
-
Contato:
- Jason Maikos, PhD
- Número de telefone: 7482 (212) 686-7500
- E-mail: Jason.Maikos@va.gov
-
Contato:
- Michael J Hyre, MS
- Número de telefone: 3339 (212) 686-7500
- E-mail: michael.hyre@va.gov
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Unilateral transtibial amputation (any etiology)
- At least 18 years old
- At least 6-months post-amputation
- Current prosthetic users (at least 6 hours/day)
Exclusion Criteria:
- Unable to ambulate on a treadmill at low to moderate speed
- Inability to tolerate the socket suspensions
- Length of the residual limb prohibits socket fitting, dynamic stereo x-ray data capture, or marker placement
- Mental impairment that impedes study compliance
- Skin conditions (i.e. burns or poor skin coverage) as well as those with severe contractures that prevent prior prosthetic wear
- Severe neuropathy, uncontrolled diabetes, have insensate foot, severe phantom pain, or a significant history of skin ulcers
- Any other significant comorbidity that would interfere with the study
- Severe circulatory problems including peripheral vascular disease and pitting edema
- Cognitive deficits or mental health problems that would limit ability to participate fully in the study protocol
- Women who are pregnant or who plan to become pregnant during the study
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Ciência básica
- Alocação: Randomizado
- Modelo Intervencional: Atribuição cruzada
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Comparador Ativo: Suction Suspension First
The residual limb will be imaged during dynamic activities while participants use suction suspension first, then while participants use elevated vacuum suspension. Dynamic stereo x-ray will take place 4-weeks after socket fitting. |
Participants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system inactive (traditional suction). Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system active. |
|
Comparador Ativo: Elevated Vacuum Suspension First
The residual limb will be imaged during dynamic activities while participants use elevated vacuum suspension first, then while participants use suction suspension. Dynamic stereo x-ray will take place 4-weeks after socket fitting. |
Participants will be fit with a socket capable of being suspended by both traditional suction and elevated vacuum. Participants will be assessed first with the elevated vacuum system active. Residual limb kinematics and skin deformation during movement tasks will be evaluated utilizing dynamic stereo x-ray. The evaluation will then be repeated with the elevated vacuum system inactive. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Changes in dynamic residual tibia kinematics between suspension techniques
Prazo: 4 weeks post socket fit
|
To evaluate the 6 degree of freedom kinematics of the residual limb within the socket, participants with transtibial amputation will walk on a treadmill at a self-selected speed, at a speed 10% faster than their self-selected speed, and also perform a step-down task from an 18 cm high platform. These movement tasks will be completed under 2 conditions: with the elevated suspension active and with the elevated system inactive (traditional suction). Up to 4 trials of dynamic stereo x-ray will be conducted for each task for each socket condition. For each task, dynamic stereo x-ray data will be collected and analyzed to determine underlying bone movement with respect to the socket. Six degree of freedom residual tibia rotations and translations relative to the prosthetic socket will be measured. |
4 weeks post socket fit
|
|
Changes in dynamic skin deformation of the residual limb between suspension techniques
Prazo: 4 weeks post socket fit
|
Radio-opaque markers will be placed on the residual limb in specific patterns. Participants will walk on a treadmill at a self-selected speed, at a speed 10% faster than their self-selected speed, and also perform a step-down task from an 18 cm high platform. These movement tasks will be completed under 2 conditions: with the elevated suspension active and with the elevated system inactive (traditional suction). Up to 4 trials of dynamic stereo x-ray will be conducted for each task for each socket condition. For each task, dynamic stereo x-ray data will be collected and analyzed to determine underlying skin deformation. The radio-opaque markers on the skin will be tracked during the dynamic trials, and their trajectories in the socket coordinate system will define the motion of the skin relative to the socket. Shear, defined as the change in angle between the markers, and compression, defined as the change in distance between markers and a neutral position, will be calculated. |
4 weeks post socket fit
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Jason Maikos, PhD, VA NY Harbor Healthcare System, New York, NY
Publicações e links úteis
Publicações Gerais
- Paglia DN, Chomack JM, Herlihy DV, Wetterstrand C, Kadkoy Y, Duchnycz R, Kelly P, O'Connor JP, D'Andrea SE, Maikos JT. Mitigation of image distortion during mechanical testing within a dynamic stereo x-ray system. Front Bioeng Biotechnol. 2025 May 19;13:1571639. doi: 10.3389/fbioe.2025.1571639. eCollection 2025.
- Maikos JT, Chomack JM, Herlihy DV, Paglia DN, Wetterstrand C, O'Connor JP, Hyre MJ, Loan JP, D'Andrea SE. Quantifying Bone and Skin Movement in the Residual Limb-Socket Interface of Individuals With Transtibial Limb Loss Using Dynamic Stereo X-Ray: Protocol for a Lower Limb Loss Cadaver and Clinical Study. JMIR Res Protoc. 2024 Apr 26;13:e57329. doi: 10.2196/57329.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- A3700-R
- 1I01RX003700-01A2 (Concessão/Contrato do NIH dos EUA)
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
De-identified individual participant data will be stored in a curated data repository that makes the data underlying scientific publications discoverable, freely usable, and citable, while promoting openly available research integrated with scholarly literature.
Prazo de Compartilhamento de IPD
After study completion
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .