ALPs单腔室新设备 (ASCEND)
单腔ALPS无导线起搏器系统在心动过缓患者中的早期可行性研究
Prospective, non-randomized, multi-center, international study designed to evaluate the initial safety and performance of the ALPS leadless pacemaker when used in patients with bradycardia.
研究概览
详细说明
The objective of this clinical trial is to assess the initial safety and performance of the autonomous leadless pacing system (ALPS) when used in patients with bradycardia. The ALPS™ is a system consisting of a leadless pacemaker, a catheter, a programmer and a home monitor. The ALPS leadless pacemaker is intended to sense the electrical activity of the heart and to provide cardiac pacing therapy in patients requiring VVI therapy. The ALPS has an energy harvester that provides the energy for the pacing therapy and communication with a home monitor, instead of a battery limited in its life time.
The study will include up to 10 participants who will be enrolled and implanted in up to 4 medical centers in the US. The duration of participation for each participant will be 24 months. Participants will be evaluated 1 month, 3, 6, 12, 18 and 24 months following the implantation. The study includes safety assessment which consists of checking for device or procedure-related major complications. The performance assessment consists of collecting and analyzing the leadless pacemaker's battery voltage and pacing parameters. In addition, the study will collect data to analyze the performance of the energy harvester.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Dalit Shav
- 电话号码:+33 147 468 515
- 邮箱:clinical@cairdac.com
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
-
Male or female, ≥ 18 years of age at enrolment
-
Subject who has a Class I or II indication for implantation of a single chamber ventricular pacemaker according to ACC/AHA/HRS/EHRA guidelines:
- Paroxysmal or permanent high-grade AV block in the presence of Atrial Fibrillation (AF)
- Paroxysmal or permanent high-grade AV block in the absence of AF, as an alternative to dual chamber pacing, when dual chamber transvenous pacing system is considered difficult, elevated risk, or not deemed necessary for effective therapy.
- Symptomatic bradycardia-tachycardia syndrome or Sinus Node Dysfunction (sinus bradycardia or sinus pauses), as an alternative to atrial or dual chamber pacing, when dual chamber transvenous pacing system is considered difficult, elevated risk, or not deemed necessary for effective therapy.
-
Subject able and willing to undergo the study requirements and is expected to be geographically stable for the duration of the follow-up.
-
Subject with a life expectancy of more than 24 months.
-
Subject is able and willing to use the Home Monitor.
-
Written informed consent to participate in the study obtained from the subject, according to local regulations, prior to initiation of any study mandated procedure.
Exclusion Criteria:
- Subject who is entirely pacemaker dependent (escape rhythm <30 bpm).
- Subject has an existing or prior pacemaker, ICD, or CRT device implant.
- Subject has unstable angina pectoris or has had an acute myocardial infarction (AMI) in the 30 days prior to eligibility assessment.
- Subject had recent cardiovascular or peripheral vascular surgery within 30 days prior to enrollment
- Subject with current implantation of a neurostimulator or any other chronically implanted device which uses current in the body. Note that a temporary pacing wire is allowed.
- Subject with a prior intervention of the tricuspid valve, implanted vena cava filter that cannot be crossed, or left ventricular assist device (LVAD).
- Subject who is morbidly obese (BMI > 40).
- Subject who has a below normal BMI (BMI<18).
- Subject whose femoral venous anatomy is unable to accommodate a 24 French introducer sheath or an implant on the right side of the heart (for example, due to obstructions or severe tortuosity) in the opinion of the implanter.
- Subject with ventricular dysfunction and LVEF ≤ 50
- Subject who is considered as unable to tolerate an urgent sternotomy.
- Subject with a known intolerance to Titanium, titanium nitride, parylene C, PEEK, platinum-iridium alloy, heparin, or sensitivity to contrast media.
- Subject for whom a single dose of 1.0 mg dexamethasone acetate may be contraindicated.
- Subject with a life expectancy of less than 24 months.
- Subject with significant co-morbid conditions or other conditions which, at the discretion of the PI, are deemed to prohibit study entry
- Subject who is currently enrolled or planning to participate in a potentially confounding drug or device trial during the course of this study. Co-enrollment in concurrent trials is only allowed when documented preapproval is obtained from the Cairdac study manager.
- Pregnant woman, or woman of childbearing potential and who is not on a reliable form of birth control.
- Subject with exclusion criteria required by local law (e.g. age, breast feeding, etc.).
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:ALPS group
It is a single arm study where participants will undergo the implantation of ALPS in the heart right ventricle. |
Participants will undergo leadless ventricular pacemaker implantation providing pacing therapy by the implant and monitoring using the home monitor. |
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
器械相关严重不良事件发生率
大体时间:3个月
|
3个月
|
|
起搏阈值(PCT)≤ 2V(0.4 ms脉冲宽度)且较植入时增幅< 1.5V、且R波振幅≥ 5.0 mV(或达到植入时水平)的受试者比例
大体时间:3个月
|
3个月
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
电池电压高于3930mV的患者比例
大体时间:3个月
|
3个月
|
|
ALPS系统和/或手术相关主要并发症的发生率
大体时间:24个月
|
24个月
|
|
电池电压高于3930mV的受试者比例
大体时间:24个月
|
24个月
|
|
起搏阈值在治疗范围内的受试者比例
大体时间:24个月
|
24个月
|
|
具有治疗可接受感知振幅的受试者比例
大体时间:24 个月
|
24 个月
|
|
患者起搏阻抗在400-2000欧姆可接受范围内的比例
大体时间:24 个月
|
24 个月
|
|
植入式设备电池的平均电压
大体时间:24个月
|
24个月
|
合作者和调查者
赞助
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- ALPS-CLNS01-001
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.