- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07461935
ALPs Nuovo Dispositivo a Camera Singola (ASCEND)
Studio di Fattibilità Preliminare del Sistema di Pacemaker Senza Fili a Camera Singola ALPS in Pazienti con Bradicardia
Prospective, non-randomized, multi-center, international study designed to evaluate the initial safety and performance of the ALPS leadless pacemaker when used in patients with bradycardia.
Panoramica dello studio
Stato
Intervento / Trattamento
Descrizione dettagliata
The objective of this clinical trial is to assess the initial safety and performance of the autonomous leadless pacing system (ALPS) when used in patients with bradycardia. The ALPS™ is a system consisting of a leadless pacemaker, a catheter, a programmer and a home monitor. The ALPS leadless pacemaker is intended to sense the electrical activity of the heart and to provide cardiac pacing therapy in patients requiring VVI therapy. The ALPS has an energy harvester that provides the energy for the pacing therapy and communication with a home monitor, instead of a battery limited in its life time.
The study will include up to 10 participants who will be enrolled and implanted in up to 4 medical centers in the US. The duration of participation for each participant will be 24 months. Participants will be evaluated 1 month, 3, 6, 12, 18 and 24 months following the implantation. The study includes safety assessment which consists of checking for device or procedure-related major complications. The performance assessment consists of collecting and analyzing the leadless pacemaker's battery voltage and pacing parameters. In addition, the study will collect data to analyze the performance of the energy harvester.
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: Dalit Shav
- Numero di telefono: +33 147 468 515
- Email: clinical@cairdac.com
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
-
Male or female, ≥ 18 years of age at enrolment
-
Subject who has a Class I or II indication for implantation of a single chamber ventricular pacemaker according to ACC/AHA/HRS/EHRA guidelines:
- Paroxysmal or permanent high-grade AV block in the presence of Atrial Fibrillation (AF)
- Paroxysmal or permanent high-grade AV block in the absence of AF, as an alternative to dual chamber pacing, when dual chamber transvenous pacing system is considered difficult, elevated risk, or not deemed necessary for effective therapy.
- Symptomatic bradycardia-tachycardia syndrome or Sinus Node Dysfunction (sinus bradycardia or sinus pauses), as an alternative to atrial or dual chamber pacing, when dual chamber transvenous pacing system is considered difficult, elevated risk, or not deemed necessary for effective therapy.
-
Subject able and willing to undergo the study requirements and is expected to be geographically stable for the duration of the follow-up.
-
Subject with a life expectancy of more than 24 months.
-
Subject is able and willing to use the Home Monitor.
-
Written informed consent to participate in the study obtained from the subject, according to local regulations, prior to initiation of any study mandated procedure.
Exclusion Criteria:
- Subject who is entirely pacemaker dependent (escape rhythm <30 bpm).
- Subject has an existing or prior pacemaker, ICD, or CRT device implant.
- Subject has unstable angina pectoris or has had an acute myocardial infarction (AMI) in the 30 days prior to eligibility assessment.
- Subject had recent cardiovascular or peripheral vascular surgery within 30 days prior to enrollment
- Subject with current implantation of a neurostimulator or any other chronically implanted device which uses current in the body. Note that a temporary pacing wire is allowed.
- Subject with a prior intervention of the tricuspid valve, implanted vena cava filter that cannot be crossed, or left ventricular assist device (LVAD).
- Subject who is morbidly obese (BMI > 40).
- Subject who has a below normal BMI (BMI<18).
- Subject whose femoral venous anatomy is unable to accommodate a 24 French introducer sheath or an implant on the right side of the heart (for example, due to obstructions or severe tortuosity) in the opinion of the implanter.
- Subject with ventricular dysfunction and LVEF ≤ 50
- Subject who is considered as unable to tolerate an urgent sternotomy.
- Subject with a known intolerance to Titanium, titanium nitride, parylene C, PEEK, platinum-iridium alloy, heparin, or sensitivity to contrast media.
- Subject for whom a single dose of 1.0 mg dexamethasone acetate may be contraindicated.
- Subject with a life expectancy of less than 24 months.
- Subject with significant co-morbid conditions or other conditions which, at the discretion of the PI, are deemed to prohibit study entry
- Subject who is currently enrolled or planning to participate in a potentially confounding drug or device trial during the course of this study. Co-enrollment in concurrent trials is only allowed when documented preapproval is obtained from the Cairdac study manager.
- Pregnant woman, or woman of childbearing potential and who is not on a reliable form of birth control.
- Subject with exclusion criteria required by local law (e.g. age, breast feeding, etc.).
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: ALPS group
It is a single arm study where participants will undergo the implantation of ALPS in the heart right ventricle. |
Participants will undergo leadless ventricular pacemaker implantation providing pacing therapy by the implant and monitoring using the home monitor. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Tasso di eventi avversi gravi correlati al dispositivo
Lasso di tempo: 3 mesi
|
3 mesi
|
|
Tasso di partecipanti con soglie di stimolazione (PCT) ≤ 2V a 0,4 ms di larghezza di impulso, e un aumento della PCT dall'impianto è inferiore a 1,5V, e ampiezze dell'onda R ≥ 5,0 mV, o un valore ≥ il valore all'impianto
Lasso di tempo: 3 mesi
|
3 mesi
|
Misure di risultato secondarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Tasso di pazienti con tensione della batteria superiore a 3930mV
Lasso di tempo: 3 mesi
|
3 mesi
|
|
Il tasso di complicanze maggiori correlate al sistema ALPS e/o alla procedura
Lasso di tempo: 24 mesi
|
24 mesi
|
|
La percentuale di soggetti in cui la tensione della batteria è superiore a 3930mV
Lasso di tempo: 24 mesi
|
24 mesi
|
|
La percentuale di soggetti con soglie di stimolazione che rientrano nell'intervallo terapeutico
Lasso di tempo: 24 mesi
|
24 mesi
|
|
Il tasso di soggetti con ampiezza di rilevamento terapeuticamente accettabile
Lasso di tempo: 24 mesi
|
24 mesi
|
|
Tasso di pazienti con impedenza di stimolazione entro l'intervallo accettabile di 400-2000 Ohm
Lasso di tempo: 24 mesi
|
24 mesi
|
|
La tensione media della batteria dell'impianto
Lasso di tempo: 24 mesi
|
24 mesi
|
Collaboratori e investigatori
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
- Fibrillazione atriale
- stimolatore cardiaco
- monitoraggio remoto
- monitoraggio domiciliare
- Bradicardia
- Blocco AV
- pacemaker senza piombo
- pacemaker senza elettrocatetere ventricolare
- Sindrome bradi-tachi
- pacemaker cardiaco senza elettrocatetere
- sistema di stimolazione senza elettrocatetere
- sistema leadless di erogazione
- pacemaker permanente senza elettrocatetere
- pacemaker senza elettrocatetere a camera singola
- terapia di stimolazione cardiaca senza elettrocatetere a camera singola
- VVI
- sistema di stimolazione leadless autonomo
- raccoglitore di energia piezoelettrica
- VOO
- monitor domestico
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- ALPS-CLNS01-001
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .