Precise Measurement of Pediatric Defibrillation Thresholds
Defibrillation Thresholds in a Pediatric Cohort Using Binary Search Protocol
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02115
- Children's Hospital Boston
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Current follow-up at Children's Hospital Boston
- Children with current or planned ICDs who are scheduled by their primary electrophysiologist for clinically necessary assessment/re-assessment of defibrillation threshold
- If the patient has an ICD system with a non-transvenous shock coil: weight ≤35kg at time of initial implant, with current weight <50kg
- If the patient has an ICD system with a conventional transvenous shock coil: current weight ≤60kg
Exclusion Criteria:
- Clinical failure of any system component not able to be addressed by hardware repair or exchange
- Hemodynamic instability that in the judgment of the primary electrophysiologist warrants abbreviation of DFT assessment
- Unsuccessful induction of fibrillation during DFT testing
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Pediatric ICD pts
Inclusion criteria for study participants included: 1) weight ≤60 kg, 2) new or existing ICD system, and 3) clinically necessary assessment of the defibrillation efficacy of the ICD system.
Transvenous systems utilized a high-voltage ICD coil with active-fixation lead attached to the right ventricular endocardial surface, whereas non-transvenous systems depended upon a high-voltage shocking coil placed within the pericardial, subcutaneous or pleural space.
To be included in the post-shock pacing portion of the study, adequate sinus and AV node function had to be present at baseline.
Exclusion criteria included 1) tenuous hemodynamic status felt to warrant abbreviation of the defibrillation efficacy testing or 2) inability to induce fibrillation during defibrillation threshold testing (DFT).
|
Measurement of the defibrillation threshold was performed using a modified binary search protocol.
This protocol specified three distinct inductions of ventricular fibrillation (VF) for all subjects, with a 3-5 minute observation/waiting period between inductions.
The initial shock energy was programmed at 9 joules (J) for all patients, with internal rescue shocks at 31J followed by device-specific maximum deliverable energy.
The outcome of the initial induction determined the programmed energies for both the initial and internal rescue shocks for the second induction, and likewise for the third induction.
All shocks were biphasic and delivered at manufacturers' default tilt, polarity and duration, and all final programmed shock vectors included an active can.
External defibrillation pads were in place for delivery of external rescue shock should the internal shocks fail.
Prior to each of the three ventricular fibrillation inductions performed as part of the binary search protocol, post-shock pacing was re-programmed using a pre-determined, stepwise protocol that progressively decreased the lower rate limit.
For the purpose of this protocol, post-shock pacing was considered necessary if 1) ≥7 ventricular-paced beats or 2) asystole >4 seconds was observed in the first 20 seconds after defibrillation, or if the systolic blood pressure demonstrated a >10% decrease from pre-induction baseline at follow-up measurement 1 minute post-defibrillation.
Rescue ventricular pacing via the programmer was available for all subjects.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Defibrillation Threshold
Time Frame: During clinical ICD procedure, as a single event
|
The defibrillation threshold is a measure of the minimum amount of energy (in Joules) that is able to successfully defibrillate an episode of ventricular fibrillation.
This measurement is specific to each individual patient with his/her specific defibrillator configuration.
There are several different strategies to measuring this in an individual patient; this study utilized the binary search protocol.
|
During clinical ICD procedure, as a single event
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Do DFTs Vary by Type of ICD Systems Implanted?
Time Frame: During clinical ICD procedure, as a single event
|
The defibrillation threshold (as measured in Joules as already described in the details regarding the primary outcome) will be compared between patients with two distinct general types of implanted defibrillator systems: 1) transvenous ICD systems (defibrillator leads located inside the vein and attached to the endocardial surface of the heart) and 2) non-transvenous ICD systems (including all other types of debrillation systems).
|
During clinical ICD procedure, as a single event
|
|
Intrinsic Heart Rate in the Immediate Post-defibrillation Period
Time Frame: During clinical ICD procedure, as a single event
|
A patient will be considered to have an intrinsic slow heart rate in the period of time immediately following defibrillation (20 seconds) if any of the following are observed: >7 paced beats, asystole >4 seconds, or experienced >10% decrease in systolic blood pressure.
|
During clinical ICD procedure, as a single event
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Andrew E Radbill, MD, Boston Children's Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 09-04-0209
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.