A Comparison of Visual Function After Bilateral Implantation of Presbyopia-Correcting Intraocular Lenses (IOLs)
A Randomized, Subject-Masked Comparison of Visual Function After Bilateral Implantation of Presbyopia-Correcting IOLs
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Sign informed consent;
- Able to attend postoperative examinations per protocol schedule;
- Diagnosed with bilateral cataracts;
- Planned cataract removal by phacoemulsification with implantation of an intraocular lens (IOL);
- Preoperative astigmatism ≤ 2.5 diopter;
- Good ocular health, with the exception of cataracts;
- Free of disease(s)/condition(s) listed in the "Caution" section of the AcrySof IQ and Acri.LISA package inserts;
- Able to undergo second eye surgery within one month of the first eye surgery;
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Previous corneal surgery;
- Planned multiple procedures during cataract/IOL implantation surgery;
- Any ocular disease and/or condition that may compromise study results;
- Pregnant or planning pregnancy during course of study;
- History of corneal disease (e.g., herpes simplex, herpes zoster keratitis, etc.)
- Diabetic retinopathy;
- Macular degeneration;
- History of retinal detachment;
- Other protocol-defined exclusion criteria may apply.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: ReSTOR +3
AcrySof® IQ ReSTOR® +3.0 D Multifocal IOL Model SN6AD1 or AcrySof® IQ ReSTOR® +3.0 D Multifocal Toric IOL Model SND1TT, lens assignment and model determined by preoperative keratometric astigmatism, bilateral implantation
|
Multifocal IOL implanted for long-term use over the lifetime of the cataract patient
Multifocal IOL with extended secondary focal point and astigmatism correction implanted for long-term use over the lifetime of the cataract patient
Other Names:
|
|
Active Comparator: Acri.LISA
Acri.LISA® 366D IOL or Acri.LISA® 466TD Toric IOL, lens assignment determined by preoperative keratometric astigmatism, bilateral implantation
|
Aspheric diffractive IOL with +3.75 D add power implanted for long-term use over the lifetime of the cataract patient
Aspheric diffractive IOL with +3.75 D add power and astigmatism correction implanted for long-term use over the lifetime of the cataract patient
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Mean Binocular Defocus VA at Month 3
Time Frame: Month 3 from second eye implantation
|
Defocus VA (an indicator of the expected range of vision with a presbyopia-correcting IOL) was tested binocularly with the participant's best spectacle correction using a chart.
Lenses of different spherical powers were placed in front of the eyes to produce varying levels of defocus.
The VA at each spherical power was measured in logarithm of the minimum angle of resolution (logMAR), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart.
A lower numeric value represents better visual acuity.
|
Month 3 from second eye implantation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Best Corrected Visual Acuity (BCVA) Across a Range of Distances at Month 3
Time Frame: Month 3 from second eye implantation
|
Visual acuity (VA) was tested binocularly (both eyes together) with correction in place if needed across a range of distances under well-lit conditions using Early Treatment of Diabetic Retinopathy Study (ETDRS) charts.
VA was measured in logarithm of the minimum angle of resolution (logMAR), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart.
A lower numeric value represents better visual acuity.
|
Month 3 from second eye implantation
|
|
Uncorrected Visual Acuity Across a Range of Distances at Month 3
Time Frame: Month 3 from second eye implantation
|
VA was tested binocularly unaided across a range of distances under well-lit conditions using Early Treatment of Diabetic Retinopathy Study (ETDRS) charts.
VA was measured in logarithm of the minimum angle of resolution (logMAR), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart.
A lower numeric value represents better visual acuity.
|
Month 3 from second eye implantation
|
|
Mean Refractive Spherical Equivalent at Month 3
Time Frame: Month 3 from second eye implantation
|
A manifest refraction (vision check) was performed using a 100% contrast ETDRS chart under well-lit conditions.
Results were documented for sphere, cylinder and axis readings.
The refractive spherical equivalent was calculated according to the formula: sphere + ½ cylinder power.
Both eyes contributed to the mean.
|
Month 3 from second eye implantation
|
|
Mean Radner Reading Speed
Time Frame: Month 3 from second eye implantation
|
Reading performance was measured using the Radner Reading Chart with no correction (without) and with best distance corrective aids (with).
Reading speed was measured in words per minute.
|
Month 3 from second eye implantation
|
|
Patient Reported Outcomes at Month 3
Time Frame: Month 3 from second eye implantation
|
The Visual Task Difficulty Assessment (VISTAS) questionnaire was completed by the subject to assess difficulty in completing everyday tasks that depend on good vision.
Tasks were rated using a 1 to 5 point scale, where 1 = no difficulty; 2 = minor difficulty; 3 = moderate difficulty; 4 = major difficulty; 5 = cannot accomplish.
Individual scores for each task were averaged to obtain the overall score for each vision type/function.
Near vision was defined as less than 50 cm; intermediate vision as 50 cm to 1 m; extended intermediate vision as 90 cm to 4 m; and distant vision as more than 4 m.
|
Month 3 from second eye implantation
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Brand Lead, Surgical, Global Medical Affairs, Alcon Research
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- M09-051
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.