Revised Algorithm for Next Generation DeVilbiss Healthcare AutoAdjust Continuous Positive Airway Pressure (CPAP)
Revised Algorithm for Next Generation DeVilbiss AutoAdjust CPAP
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Massachusetts
-
Newton, Massachusetts, United States, 02459
- Neurocare, Inc.
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Apnea hypopnea index ≥ 15 / hour of sleep on the diagnostic polysomnogram, or diagnostic component of a split night polysomnogram
- Sleep efficiency reported on CPAP titration night PSG should be > 78%
- Diagnosis of moderate to severe obstructive sleep apnea (AHI ≥15) or central/complex sleep apnea
- On stable CPAP or APAP [Automatic Positive Airway Pressure] therapy, with compliant use averaging 4 or more hours nightly
- Age 21-75 years
- Predominately central sleep apnea for up to 10 subjects only
- Willingness to give written informed consent and ability to adhere to visit schedule
Exclusion Criteria:
Diagnosis of mild sleep apnea
- CPAP naïve patients
- Co-morbid conditions which render participation to be at risk. These may include patients with congestive heart failure, COPD [Chronic Obstructive Pulmonary Disease] or psychiatric illness
- Allergies to mask materials
- Evidence of another primary sleep disorder
- Evidence of arousing periodic limb movements during titration
- Contraindications as listed on product labeling
- Pregnant
- Currently diagnosed with depression if symptomatic
- Deemed medically unsuitable by investigator
- Evidence of any type of infection or treatment of an infectious condition during the period of research participation
- Have a bi-level requirement, or prescribed a bi-level therapy device
- CPAP pressure >15cmH2O
- Subjects with tracheotomy
- Uncontrolled hypertension
- Require supplemental oxygen
- Stimulants, major tranquillizers or antipsychotics
- Restless Leg Syndrome or Periodic Leg Movement Index of > 5 per hour
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: All subjects
All subjects underwent a sleep study with DeVilbiss AutoAdjust CPAP with revised algorithm simultaneously with hand-scored PSG.
|
Subjects attended a one-night polysomnogram (PSG) titration study.
DeVilbiss AutoAdjust CPAP with a revised algorithm was compared to hand-scored PSG to determine whether the machine results were equivalent to hand scores.
Each subject acted as their own control for assessing accuracy of sleep event analysis and prescribed CPAP pressure.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
% Agreement Between Reviewer and Machine Pressure Settings During Sleep Study
Time Frame: 1 night
|
The primary objective for the study was demonstrating effectiveness of therapy provided by the DeVilbiss AutoAdjust device as reported by the expert human reviewer.
The primary endpoint was that expert human reviewer should agree with pressure changes made by the machine during each 20-minute epoch at least 80% of the time.
Expert human reviewer reviewed each study and made a determination at 20-minute time points, in context of REM/NON-REM sleep and supine/non-supine positions, marking the machine pressure response with an "agree" or "disagree."
Pressure changes might show no change, increase or decrease during the 20-minute epoch.
|
1 night
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- DHC-002
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Obstructive Sleep Apnea
-
NCT07399782Not yet recruitingSleep Apnea/Hypopnea Syndrome | Sleep Apnea Syndrome, Obstructive | Sleep Apnea Syndrome (OSAS) | Sleep Apnea - Obstructive
-
NCT07186725RecruitingObstructive Sleep Apnea (SAOS) | Obstructive Sleep Apnea (OSAS)
-
NCT07301762Enrolling by invitationObstructive Sleep Apnea | OSA | Obstructive Sleep Apnea (OSA)
-
NCT07545421Not yet recruitingObstructive Sleep Apnea
-
NCT07337239Not yet recruiting
-
NCT07331285Not yet recruitingObstructive Sleep Apnea
-
NCT07303452RecruitingObstructive Sleep Apnea
-
NCT07397780Active, not recruitingObstructive Sleep Apnea
Clinical Trials on DeVilbiss AutoAdjust CPAP with revised algorithm
-
NCT02635100TerminatedSleep Apnea | Sleep Disordered Breathing