Effect of Intrathoracic Pressure Regulation on Traumatic Brain Injury
Effects of Intrathoracic Pressure Regulation Therapy in Patients With Elevated Intracranial Pressure Due to Brain Injury or Intracranial Pathology
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- ≥15 years of age
- intubated and mechanically ventilated on a volume controlled mode
- head injury or other intracranial pathology with ICP of ≥15 mmHg
- arterial line in place
- SpO2 ≥95%
- MAP >60
- in ICU or about to undergo neurosurgery with planned placement of an ICP monitor
- inclusion presents no significant delays to planned emergent neurosurgery
- prior written informed consent
Exclusion Criteria:
- cardiac or pulmonary injury impacting intrathoracic pressure
- confirmed pneumothorax or hemothorax
- PaO2/FiO2 <300
- serious neck injury resulting in neck swelling with jugular venous compression
- evidence of ongoing uncontrolled bleeding
- respiratory disease such as COPD, interstitial lung disease, or other parenchymal or pulmonary vascular disease
- congestive heart failure
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Group A
tidal volume setting of 6ml/kg with the -7cm H2O ITPR as first device
|
Single use disposable non-invasive device that is connected to a vacuum source and a means to deliver a positive pressure breath and generates negative3 pressure during the expiratory phase, thus creating subatmospheric intrathoracic pressure of -7 cmH2O between periods of positive pressure ventilations.
Other Names:
|
|
Active Comparator: Group B
tidal volume setting of 8ml/kg with the -7cm H2O ITPR as first device
|
Single use disposable non-invasive device that is connected to a vacuum source and a means to deliver a positive pressure breath and generates negative3 pressure during the expiratory phase, thus creating subatmospheric intrathoracic pressure of -7 cmH2O between periods of positive pressure ventilations.
Other Names:
|
|
Active Comparator: Group C
tidal volume setting of 6ml/kg with the -12cm H2O ITPR as first device
|
Single use disposable non-invasive device that is connected to a vacuum source and a means to deliver a positive pressure breath and generates negative3 pressure during the expiratory phase, thus creating subatmospheric intrathoracic pressure of -12 cmH2O between periods of positive pressure ventilations.
Other Names:
|
|
Active Comparator: Group D
tidal volume setting of 8ml/kg with the -12cm H2O ITPR as first device
|
Single use disposable non-invasive device that is connected to a vacuum source and a means to deliver a positive pressure breath and generates negative3 pressure during the expiratory phase, thus creating subatmospheric intrathoracic pressure of -12 cmH2O between periods of positive pressure ventilations.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Intracranial Pressure (ICP)
Time Frame: 15 minutes after device is activated
|
Change in ICP from baseline will be compared with the ICP during 15 minutes of ITPR use.
|
15 minutes after device is activated
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Cerebral Perfusion Pressure (CPP)
Time Frame: 15 minutes after device activation
|
Measurement of the difference between baseline CPP and CPP at 15 minutes
|
15 minutes after device activation
|
|
Lung Compliance
Time Frame: baseline and immediately after device removal
|
Change in lung compliance following each ITPR treatment compared to baseline.
|
baseline and immediately after device removal
|
|
Arterial Blood Gases (PaCO2)
Time Frame: 15 minutes after device activation
|
Arterial blood gases will be collected.
|
15 minutes after device activation
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- ACSI W81XWH-11-1-0542
- W81XWH-11-1-0542 (Other Grant/Funding Number: Department of Defense)
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.