Comparison of BuMA eG Based BioDegradable Polymer Stent With EXCEL Biodegradable Polymer Sirolimus-eluting Stent in "Real-World" Practice (PANDA-III)
A Prospective, Multicenter, RAndomized, CoNtrolled, Study Comparing the Safety and Efficacy Between BuMA eG Based BioDegradable Polymer Stent and EXCEL Biodegradable Polymer Sirolimus-eluting Stent in "ReAl-World" Practice (PANDA-III)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Beijing, China, 100037
- Fuwai Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- The patient must be ≥18 of age;
- Symptomatic ischemic heart disease and/or objective evidence of myocardial ischemia including chronic stable coronary artery disease, or acute coronary syndrome including non-ST-elevation and ST-elevation myocardial infarction;
- Acceptable candidate for CABG;
- The patient is willing to comply with specified follow-up evaluations;
- Patients who agree to accept the follow-up visits.
- Patients can understand the study objectives psychologically and linguistically and show the sufficient compliance to the study protocol. Patients present acceptance of the risks and benefits described in the informed consent form.
- At least one lesion with a diameter stenosis >50% or more suitable for coronary stent implantation in a vessel with a reference diameter ranging from 2.5 mm to 4.0 mm;
Exclusion Criteria:
- Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure.
- Patient has other medical illness (e.g., cancer, known malignancy, congestive heart failure, organ transplant recipient or candidate) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e., less than 1 year);
- Patient has a known hypersensitivity or contraindication to aspirin, heparin, clopidogrel/ticlopidine, stainless steel alloy, cobalt chromium, rapamycin , styrene-butylenes-styrene or poly-lactic acid (PLA) polymer, and/or contrast sensitivity that cannot be adequately pre-medicated;
- Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study;
- Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: BuMA group
Implant BuMA stent only
|
This group will contain 1175 subjects.
|
|
Active Comparator: EXCEL group
Implant EXCEL stent
|
This group will contain 1175 subjects.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Target lesion failure (a composite of cardiac death, target lesion myocardial infarction and ischemia driven target lesionsrevascularization TLR) at 1 year
Time Frame: 12 months after PCI
|
12 months after PCI
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Runlin Gao, Dr, Fuwai Hospital, Chinese Academy of Medical Science
Publications and helpful links
General Publications
- Zhang R, Wu S, Yuan S, Guan C, Zou T, Qiao Z, Xie L, Wang H, Song L, Xu B, Dou K. Effects of diabetes mellitus on post-intervention coronary physiological assessment derived by quantitative flow ratio in patients with coronary artery disease underwent percutaneous coronary intervention. Diabetes Res Clin Pract. 2022 Apr;186:109839. doi: 10.1016/j.diabres.2022.109839. Epub 2022 Mar 21.
- Zhang R, Xu B, Dou K, Guan C, Zhao Y, Wang X, Zou T, Qiao Z, Xie L, Wang H, Yuan S, Song L, Tu S, Wang Y, Wijns W. Post-PCI outcomes predicted by pre-intervention simulation of residual quantitative flow ratio using augmented reality. Int J Cardiol. 2022 Apr 1;352:33-39. doi: 10.1016/j.ijcard.2022.01.054. Epub 2022 Jan 31.
- Zhang R, Dou K, Guan C, Zou T, Zhang M, Yuan S, Qiao Z, Xie L, Sun Z, Song L, Qiao S, Stone GW, Xu B. Outcomes of quantitative flow ratio-based percutaneous coronary intervention in an all-comers study. EuroIntervention. 2022 Feb 18;17(15):1240-1251. doi: 10.4244/EIJ-D-21-00176.
- Zhang R, Song C, Guan C, Liu Q, Wang C, Xie L, Sun Z, Cai M, Zhang M, Wang H, Liu J, Dou K, Xu B. Prognostic Value of Quantitative Flow Ratio Based Functional SYNTAX Score in Patients With Left Main or Multivessel Coronary Artery Disease. Circ Cardiovasc Interv. 2020 Oct;13(10):e009155. doi: 10.1161/CIRCINTERVENTIONS.120.009155. Epub 2020 Oct 12.
- Jia S, Guan C, Yuan J, Cao X, Qin L, Li Y, Li Z, Nie S, Hou S, Zhang M, Brouwer M, Suryapranata H, Xu B, Gao R. Two-year safety evaluation of a biodegradable polymer sirolimus-eluting stent with increased drug elution and polymer absorption kinetics in complex patient and lesion cohort. Catheter Cardiovasc Interv. 2020 Feb;95(2):206-215. doi: 10.1002/ccd.28288. Epub 2019 Apr 16.
- Wang J, Guan CD, Yuan JS, Gao RL, Xu B, Qiao SB. [Prognostic value of SYNTAX score on 1 year outcome in patients underwent percutaneous coronary intervention]. Zhonghua Xin Xue Guan Bing Za Zhi. 2018 Apr 24;46(4):267-273. doi: 10.3760/cma.j.issn.0253-3758.2018.04.004. Chinese.
- Xu B, Gao R, Yang Y, Cao X, Qin L, Li Y, Li Z, Li X, Lin H, Guo Y, Ma Y, Wang J, Nie S, Xu L, Cao E, Guan C, Stone GW; PANDA III Investigators. Biodegradable Polymer-Based Sirolimus-Eluting Stents With Differing Elution and Absorption Kinetics: The PANDA III Trial. J Am Coll Cardiol. 2016 May 17;67(19):2249-2258. doi: 10.1016/j.jacc.2016.03.475.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- PANDA-Ⅲ
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.