Dynamic Respiratory Muscle Function in Late-Onset Pompe Disease (DRMF)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Florida
-
Gainesville, Florida, United States, 32606
- University of Florida
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Confirmed diagnosis of Pompe disease OR
- Be an age and gender-matched unaffected control subject
Exclusion Criteria:
- Pre-existing obstructive lung disease or asthma
- Forced vital capacity (FVC) <30% or >80% of age/gender predicted values
- Inability to travel to the study site
- Requirement for positive pressure ventilator support when awake and upright
- Participation in longitudinal studies that may independently alter lung function
- Presence of any other chronic medical condition that, in the opinion of the investigator, would make the subject unsuitable for the study
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Pompe subjects
These subjects will receive a thoracic MRI, spirometry, inspiratory load compensation, maximal inspiratory pressure, resting breathing pattern, respiratory muscle endurance test.
|
Imaging of the diaphragm will be completed during resting breathing, and then during a maximal voluntary ventilation maneuver.
Upright forced vital capacity (FVC)
A spring-loaded pressure device will resist inspiration.
The patient must generate the threshold inspiratory pressure to receive airflow.
The changes in breathing timing, flow and volume will be recorded.
Measure the maximal airflow on inhalation
Other Names:
The breathing pattern will be assessed when the subject is seated and in a relaxed state.
Evaluates the time limit that a participant can maintain ventilation while breathing with a submaximal inspiratory threshold load.
|
|
Control subjects
These subjects will receive a thoracic MRI, spirometry, inspiratory load compensation, maximal inspiratory pressure, resting breathing pattern, respiratory muscle endurance test.
|
Imaging of the diaphragm will be completed during resting breathing, and then during a maximal voluntary ventilation maneuver.
Upright forced vital capacity (FVC)
A spring-loaded pressure device will resist inspiration.
The patient must generate the threshold inspiratory pressure to receive airflow.
The changes in breathing timing, flow and volume will be recorded.
Measure the maximal airflow on inhalation
Other Names:
The breathing pattern will be assessed when the subject is seated and in a relaxed state.
Evaluates the time limit that a participant can maintain ventilation while breathing with a submaximal inspiratory threshold load.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Inspiratory Load Compensation - Inspiratory Volume
Time Frame: Day 1
|
For ILC testing, a commercially available, spring-loaded device provided a pressure load to inspiration that is independent of inspiratory flow.
The patient had to generate enough threshold inspiratory pressure in order to receive airflow.
The tension of the spring was adjusted to regulate the threshold pressure of the imposed load.
Volume, flow and timing responses were evaluated to an inspiratory threshold load equivalent to 40% of PImax.
|
Day 1
|
|
Respiratory Muscle Endurance Task
Time Frame: Day 2
|
Endurance was evaluated by identifying the time limit (Tlim) that a participant could maintain ventilation while breathing with a submaximal inspiratory threshold load.
The test begin after a one-hour rest.
After reaching a steady state breathing pattern (e.g.
stable tidal volumes for >30 seconds), a threshold inspiratory load equivalent to 40% of PIMAX was placed on the inspiratory port of the mouthpiece.
During the loaded breathing condition, the respiratory rate was set to each subject's self-selected resting breathing rate.
The perceived exertion was monitored, and subjects received encouragement to maintain the target rate and mouth pressure.
Encouragement was provided to maintain the established breathing pattern and to continue to task failure.
The test ended when the subject could not open the threshold valve for three consecutive breaths.
|
Day 2
|
|
Inspiratory Load Compensation - Inspiratory Flow
Time Frame: Day 1
|
For ILC testing, a commercially available, spring-loaded device provided a pressure load to inspiration that is independent of inspiratory flow.
The patient had to generate enough threshold inspiratory pressure in order to receive airflow.
The tension of the spring was adjusted to regulate the threshold pressure of the imposed load.
Volume, flow and timing responses were evaluated to an inspiratory threshold load equivalent to 40% of PImax.
|
Day 1
|
|
Inspiratory Load Compensation - Inspiratory Time
Time Frame: Day 1
|
For ILC testing, a commercially available, spring-loaded device provided a pressure load to inspiration that is independent of inspiratory flow.
The patient had to generate enough threshold inspiratory pressure in order to receive airflow.
The tension of the spring was adjusted to regulate the threshold pressure of the imposed load.
Volume, flow and timing responses were evaluated to an inspiratory threshold load equivalent to 40% of PImax.
|
Day 1
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Thoracic MRI
Time Frame: Day 1
|
Chest wall and diaphragmatic motions was measured in three planes with dynamic magnetic resonance imaging (MRI).
The cradio-caudal change in diaphragm excursion between full inspiration and full expiration (representing diaphragm descent) was measured in the frontal plane.
The anterior-posterior change in the area of the right and left sides of the chest cavity was measured in the sagittal plane (representing chest expansion).
Diaphragm and chest excursion was recorded dynamically during 30-second periods of resting breathing and deep breathing.
|
Day 1
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Barbara K. Smith, PT, PhD, University of Florida
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Metabolic Diseases
- Brain Diseases
- Central Nervous System Diseases
- Nervous System Diseases
- Genetic Diseases, Inborn
- Carbohydrate Metabolism, Inborn Errors
- Metabolism, Inborn Errors
- Lysosomal Storage Diseases
- Brain Diseases, Metabolic
- Brain Diseases, Metabolic, Inborn
- Lysosomal Storage Diseases, Nervous System
- Glycogen Storage Disease
- Glycogen Storage Disease Type II
Other Study ID Numbers
Other Study ID Numbers
- IRB201400763
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.