Electrical Stimulation of the Muscle Pumps of the Leg (Muscle Pump)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- 18 years or older
- Current good health
Exclusion Criteria:
- History of cardiovascular disease
- Ankle Brachial Pressure Index <0.9
- Venous reflux>0.5s
- Pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: BASIC_SCIENCE
- Allocation: NON_RANDOMIZED
- Interventional Model: SINGLE_GROUP
- Masking: TRIPLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: 1
Stimulation of muscle in this order: vastus medials, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius, lateral head gastrocnemius
|
Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol.
1Hz, pulse duration 1ms, maximum compliance voltage 200V.
Current set to twice motor threshold
|
|
Experimental: 2
Stimulation of muscle in this order: rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius, lateral head gastrocnemius, vastus medials
|
Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol.
1Hz, pulse duration 1ms, maximum compliance voltage 200V.
Current set to twice motor threshold
|
|
Experimental: 3
Stimulation of muscle in this order: vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris
|
Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol.
1Hz, pulse duration 1ms, maximum compliance voltage 200V.
Current set to twice motor threshold
|
|
Experimental: 4
Stimulation of muscle in this order: tibialis anterior, peroneus longus, and the medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis
|
Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol.
1Hz, pulse duration 1ms, maximum compliance voltage 200V.
Current set to twice motor threshold
|
|
Experimental: 5
Stimulation of muscle in this order: peroneus longus, medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis, tibialis anterior
|
Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol.
1Hz, pulse duration 1ms, maximum compliance voltage 200V.
Current set to twice motor threshold
|
|
Experimental: 6
Stimulation of muscle in this order: medial head gastrocnemius, lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus
|
Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol.
1Hz, pulse duration 1ms, maximum compliance voltage 200V.
Current set to twice motor threshold
|
|
Experimental: 7
Stimulation of muscle in this order: lateral head gastrocnemius, vastus medials, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, medial head gastrocnemius,
|
Stimulation with Digitimer (DS7A HV, Digitimer Ltd, UK) over motor point of muscle in protocol.
1Hz, pulse duration 1ms, maximum compliance voltage 200V.
Current set to twice motor threshold
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Venous Haemodynamic Measurements (Volume Flow Rate)
Time Frame: Baseline compared to that after 10-mins stimulation (2-mins to take measurements)
|
Measurement by ultrasound, in right femoral vein.
Flow rate (ml/min).
|
Baseline compared to that after 10-mins stimulation (2-mins to take measurements)
|
|
Venous Haemodynamic Measurements (Time Averaged Maximum Velocity)
Time Frame: Baseline compared to that after 10-mins stimulation (2-mins to take measurements)
|
Measurement by ultrasound, in right femoral vein.
Time averaged maximum velocity (cm/s).
|
Baseline compared to that after 10-mins stimulation (2-mins to take measurements)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Pain Grading on Stimulation
Time Frame: During stimulation (10-mins each muscle)
|
Visual analogue scale (0-minimum pain, to 100-maximum pain)
|
During stimulation (10-mins each muscle)
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 15IC2528
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.