Total Knee Replacement Component Alignment Using Manual Versus Custom Instrumentation
- To determine whether the low-dose, biplanar x-ray imaging (EOS) has the same accuracy as computed axial tomography (CT)
- To validate low-dose, biplanar x-ray imaging (EOS) as a tool to evaluate 3-dimensional alignment of Total Knee Replacement implants.
- To evaluate differences in total knee replacement implant alignment in patients whose arthroplasty is performed using manual or custom instrumentation derived from preoperative CT
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Achieving optimal prosthetic alignment of the femoral, tibial and patellar components during Total Knee Replacement (TKR) is of great importance as it contributes to better function, less pain and improved quality of life.TKR requires accuracy in the execution of bone cuts in the correct orientation to the coronal, sagittal and axial planes. Malposition potentially leads to increased mechanical stress on the bearing surfaces and inevitably to earlier loosening.
Computed Axial Tomography (CT) is the gold standard technique to evaluate implant alignment in the coronal, sagittal and axial planes. As such, CT has imaging has been used to create custom instrumentation with purported likely improvement in surgical outcomes. Customized instrumentation created from a preoperative CT has been shown to be safe and effective, with no reported difference in patient outcomes and similar total knee arthroplasty component alignment. However, taking into consideration CT's high levels of radiation, cost expenses and its inability to obtain images of the limb in weight-bearing position, CT scan cannot be used routinely as a postoperative tool to evaluate TKR implant positioning.
The imaging system manufactured by EOS Imaging (formerly Biospace Med, Paris) is a biplanar, low-dose radiation, full body, high resolution, radiological imaging system allowing simultaneous acquisition in the coronal and sagittal planes and in standing position.EOS' main benefits are the considerable reduction in radiation dose (up to 1000 times less than for CT and ten times less than the plain radiography) by using a gaseous detector. George Charpak, the inventor, was awarded the Nobel Prize in 1992 for this work. Moreover, the EOS system can provide 3D images by using the appropriate software algorithms, thus providing a low-radiation alternative to CT.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Illinois
-
Chicago, Illinois, United States, 60611
- Northwestern Medicine Department of Orthopaedic Surgery
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Radiographically confirmed diagnosis of osteoarthritis (OA)
- Failure of non-operative treatment for the diagnosis of symptomatic osteoarthritis
- Age greater than 18 years
- Desire to proceed with elective TKR
- Completion of informed consent and signature of written consent form
Exclusion Criteria:
- Ligamentous instability that may necessitate a constrained TKR implant
- Retained hardware in the distal femur or proximal tibia of the operative extremity
- Medical contraindication to undergo preoperative CT, or inability to tolerate preoperative CT
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: RANDOMIZED
- Interventional Model: FACTORIAL
- Masking: SINGLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Manual (tibia) and manual (femur)
Knee replacement with Medacta GMK Sphere implants using manual instrumentation for both the tibia component and the femur component
|
|
|
Other: Manual (tibia) and custom (femur)
Knee replacement with Medacta GMK Sphere implants using manual instrumentation for the tibia component and custom instrumentation for the femur component
|
|
|
Other: Custom (tibia) and custom (femur)
Knee replacement with Medacta GMK Sphere implants using custom instrumentation for both the tibia component and the femur component
|
|
|
Other: Custom (tibia) and manual (femur)
Knee replacement with Medacta GMK Sphere implants using custom instrumentation for the tibia component and manual instrumentation for the femur component
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Post-Operative Hip-Knee-Angle (HKA)
Time Frame: Pre-operative, 6 wks. post-op
|
Measured HKA change from pre-operative EOS longstanding X-ray to post-operative EOS at 6wks.
comparing groups receiving manual instrumentation versus custom instrumentation
|
Pre-operative, 6 wks. post-op
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Tibial Varus Deformity
Time Frame: Pre-operative, 6 wks. post-op
|
Measured change between pre-operative planning report & post-operative EOS longstanding radiograph in varus deformity of the operative joint
|
Pre-operative, 6 wks. post-op
|
|
Femoral Valgus Deformity
Time Frame: Pre-operative, 6 wks. post-op
|
Measured change between pre-operative planning report & post-operative EOS longstanding radiograph in varus deformity of the operative joint
|
Pre-operative, 6 wks. post-op
|
|
Tibial Posterior Slope (Mean Deviation)
Time Frame: Pre-Operative - 6 wk. Post-Operative
|
Deviation from pre-operative planning template & 6 wk.
post-operative longstanding EOS radiograph
|
Pre-Operative - 6 wk. Post-Operative
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- STU00200223
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Osteoarthritis of Knee
-
NCT06717529CompletedOsteoarthritis | Osteoarthritis of the Knee | Osteoarthritis of Knee | Osteoarthritis of the Knees | Osteoarthritis (OA) of the Knee | Osteoarthritis Knee | Osteoarthritis in the Knee | Osteoarthritis of Knee Joint
-
NCT07193368CompletedOsteoarthritis | Knee Osteoarthritis | Osteoarthritis of the Knee | Degenerative Joint Disease of the Knee
-
NCT02285725CompletedDegenerative Lesion of Articular Cartilage of Knee | Degeneration; Articular Cartilage, Knee | Unilateral Primary Osteoarthritis of Knee | Osteoarthritis Knee
-
NCT01765296CompletedLocalized Primary Osteoarthritis of Hip | Localized Primary Osteoarthritis of Knee
-
NCT07267793RecruitingOsteoarthritis | Knee Osteoarthritis | Degenerative Joint Disease of Knee | Cartilage Defects of the Knee | Knee Pain Arthritis
-
NCT03274713UnknownOsteoarthritis Of Knee
-
NCT02280538Unknown
-
NCT03469193Completed
-
NCT02722811Unknown
-
NCT07551856Not yet recruitingOsteoarthritis | Knee Osteoarthritis | Osteoarthritis (OA) | Osteo Arthritis | Osteoarthritis in the Knee | Osteoarthritis (Knee) | Osteo Arthritis of the Knee
Clinical Trials on Medacta GMK Sphere
-
NCT03391323CompletedOsteoarthritis | Osteoarthritis, Knee | Joint Disease
-
NCT05461638WithdrawnKnee Osteoarthritis | Knee Pain Chronic
-
NCT02966613CompletedOsteoarthritis,Knee
-
NCT02199600Active, not recruitingArthritis | Rheumatoid Arthritis | Avascular Necrosis | Traumatic Arthritis | Poly-arthritis
-
NCT05863741RecruitingTotal Knee Arthroplasty
-
NCT05003414Active, not recruitingArthritis | Rheumatoid Arthritis | Avascular Necrosis | Traumatic Arthritis | Poly-arthritis