Ultra Protective Ventilation During Venoarterial Extracorporeal Membrane Oxygenation (UPV-ECMO) (UPV-ECMO)
Effect of Ultraprotective Ventilation on the Lung Inflammatory Response in Patients With Acute Pulmonary Edema Treated With Venoarterial Extracorporeal Oxygenation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Principado De Asturias
-
Oviedo, Principado De Asturias, Spain, 33011
- Hospital Universitario Central de Asturias (HUCA)
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Cardiogenic pulmonary edema supported by venoarterial extracorporeal membrane oxygenation.
- Invasive mechanical ventilatory support under sedation.
Exclusion Criteria:
- Immunosupresion.
- Hemodynamic instability refractory to mechanical support, conditioning an end-of-life approach and terminal situation.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Recruited patients
Ultraprotective ventilation
|
Adjusting ventilator parameters for 3 ml/kg of tidal volume in order to achieve the ultra protective strategy
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in lung inflammatory mediators levels
Time Frame: Baseline and 18 hours after the intervention
|
Bronchoalveolar lavage cytokines levels, measured in ng/ml
|
Baseline and 18 hours after the intervention
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Guillermo M Albaiceta, HUCA-FINBA, Universidad de Oviedo
Publications and helpful links
General Publications
- Terragni PP, Rosboch G, Tealdi A, Corno E, Menaldo E, Davini O, Gandini G, Herrmann P, Mascia L, Quintel M, Slutsky AS, Gattinoni L, Ranieri VM. Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome. Am J Respir Crit Care Med. 2007 Jan 15;175(2):160-6. doi: 10.1164/rccm.200607-915OC. Epub 2006 Oct 12.
- Bein T, Weber-Carstens S, Goldmann A, Muller T, Staudinger T, Brederlau J, Muellenbach R, Dembinski R, Graf BM, Wewalka M, Philipp A, Wernecke KD, Lubnow M, Slutsky AS. Lower tidal volume strategy ( approximately 3 ml/kg) combined with extracorporeal CO2 removal versus 'conventional' protective ventilation (6 ml/kg) in severe ARDS: the prospective randomized Xtravent-study. Intensive Care Med. 2013 May;39(5):847-56. doi: 10.1007/s00134-012-2787-6. Epub 2013 Jan 10.
- Fan E, Gattinoni L, Combes A, Schmidt M, Peek G, Brodie D, Muller T, Morelli A, Ranieri VM, Pesenti A, Brochard L, Hodgson C, Van Kiersbilck C, Roch A, Quintel M, Papazian L. Venovenous extracorporeal membrane oxygenation for acute respiratory failure : A clinical review from an international group of experts. Intensive Care Med. 2016 May;42(5):712-724. doi: 10.1007/s00134-016-4314-7. Epub 2016 Mar 23.
- Acute Respiratory Distress Syndrome Network; Brower RG, Matthay MA, Morris A, Schoenfeld D, Thompson BT, Wheeler A. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000 May 4;342(18):1301-8. doi: 10.1056/NEJM200005043421801.
- Figueroa-Casas JB, Montoya R. Effect of Tidal Volume Size and Its Delivery Mode on Patient-Ventilator Dyssynchrony. Ann Am Thorac Soc. 2016 Dec;13(12):2207-2214. doi: 10.1513/AnnalsATS.201605-362OC.
- Determann RM, Royakkers A, Wolthuis EK, Vlaar AP, Choi G, Paulus F, Hofstra JJ, de Graaff MJ, Korevaar JC, Schultz MJ. Ventilation with lower tidal volumes as compared with conventional tidal volumes for patients without acute lung injury: a preventive randomized controlled trial. Crit Care. 2010;14(1):R1. doi: 10.1186/cc8230. Epub 2010 Jan 7.
- Leligdowicz A, Fan E. Extracorporeal life support for severe acute respiratory distress syndrome. Curr Opin Crit Care. 2015 Feb;21(1):13-9. doi: 10.1097/MCC.0000000000000170.
- Schmidt M, Stewart C, Bailey M, Nieszkowska A, Kelly J, Murphy L, Pilcher D, Cooper DJ, Scheinkestel C, Pellegrino V, Forrest P, Combes A, Hodgson C. Mechanical ventilation management during extracorporeal membrane oxygenation for acute respiratory distress syndrome: a retrospective international multicenter study. Crit Care Med. 2015 Mar;43(3):654-64. doi: 10.1097/CCM.0000000000000753.
- Amado-Rodriguez L, Del Busto C, Lopez-Alonso I, Parra D, Mayordomo-Colunga J, Arias-Guillen M, Albillos-Almaraz R, Martin-Vicente P, Lopez-Martinez C, Huidobro C, Camporota L, Slutsky AS, Albaiceta GM. Biotrauma during ultra-low tidal volume ventilation and venoarterial extracorporeal membrane oxygenation in cardiogenic shock: a randomized crossover clinical trial. Ann Intensive Care. 2021 Aug 28;11(1):132. doi: 10.1186/s13613-021-00919-0.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- FINBA_CritLab_1
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Access Criteria
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
- SAP
- ICF
- ANALYTIC_CODE
- CSR
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.