Black Star - Magnetic Stent Removal in Transplant Patients
Comparison of Cystoscopic Removal Versus Magnetic Device Removal of Ureteral Stents in Renal Transplant Recipients
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
To curtail the pain and discomfort during cystoscopic stent removal and in order to improve patient's quality of life, a newly developed ureteral stent with a small magnet at its distal end and a customized magnetic retrieval catheter is recently used in Europe. The product is Black-Star® with a retrieval device by Urotech (Achenmühle, Germany). The magnetic Blackstar stent is a ureteral stent with a small magnet fixed with a string at the distal loop. The placement of stent is similar as routinely done on a guidewire, the only difference is to include the magnetic piece over the guidewire. To remove the stent a customized catheter with a magnetic Tiemann tip is used. The catheter is inserted after urethral application of a standard lubricant and removed with the stent after coming in contact with the stent's magnet.
The stent comes in various sizes and is currently being used in Europe. The studies have concluded fast and easy retrieval of stent without requirement of cystoscopy and decreased patient discomfort.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Ontario
-
Hamilton, Ontario, Canada, L8N4A6
- St. Joseph's Healthcare Hamilton
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients at least 18 years of age and capable of giving informed consent
- Patients scheduled for deceased donor renal transplant surgery
Exclusion Criteria:
1) Patients undergoing Live donor renal transplant
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Magnetic Stent
Patients who are undergoing renal transplant surgery for the treatment of end stage renal failure and randomized for magnetic stent group will receive magnetic stent and the removal of stent would be done by help of magnetic device.
|
Patients who are undergoing renal transplant surgery for the treatment of end stage renal failure will be assigned to magnetic stent or routine stent using computer generated randomization method in the operating room.
Those who receive magnetic stent would get their stent removal by magnetic device retrieval and not by routine cystoscopy.
Other Names:
|
|
No Intervention: Routine stent
Patients who are undergoing renal transplant surgery for the treatment of end stage renal failure and randomized for routine stent would receive routine stent and the removal of stent would be done by cystoscopy
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Feasibility and patient comfort of the retrieval device, using standard validated questionnaire Ureteral Stent Symptom Questionnaire (USSQ)
Time Frame: 3-6 weeks
|
All patients will be followed up 4 weeks post renal transplant surgery, until ureteral stent removal.
Feasibility and comfort of stent retrieval, Ureteral Stent Symptom Questionnaire (USSQ) at 4 weeks before stent removal and 1 week post stent removal.
|
3-6 weeks
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Outcome measure: Retrieval time
Time Frame: Baseline (intraoperatively)
|
Retrieval time in minutes: The time taken for ureteric stent removal (both routine and magnetic stent) will be documented and mean time taken will be calculated.
This will show which technique takes less time.
|
Baseline (intraoperatively)
|
|
Outcome measure: Infection rate
Time Frame: 3-6 weeks
|
Infection rates: Number of Urine culture positive with stent in situ and after removal of stent (both routine and magnetic stent).
This will suggest if magnetic stent is associated with an increased incidence of urinary tract infections as compared to the routine stent.
|
3-6 weeks
|
|
Outcome measure: Cost effectiveness
Time Frame: 3-6 weeks
|
Cost effective analysis: Units will be Canadian Dollars; we will analyze the cost of disposables, sterilization of instruments, use of cystoscopy suite and also nursing and surgeon charges.
Mean cost taken for either procedure will be compared to find cost effectiveness
|
3-6 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Theckumparampil N, Elsamra SE, Carons A, Salami SS, Leavitt D, Kavoussi A, Motola J, Smith A, Okeke Z. Symptoms after removal of ureteral stents. J Endourol. 2015 Feb;29(2):246-52. doi: 10.1089/end.2014.0432. Epub 2014 Sep 17.
- Kumar A, Kumar R, Bhandari M. Significance of routine JJ stenting in living related renal transplantation: a prospective randomised study. Transplant Proc. 1998 Nov;30(7):2995-7. doi: 10.1016/s0041-1345(98)00902-6. No abstract available.
- Wilson CH, Bhatti AA, Rix DA, Manas DM. Routine intraoperative stenting for renal transplant recipients. Transplantation. 2005 Oct 15;80(7):877-82. doi: 10.1097/01.tp.0000181197.21706.fa.
- Englesbe MJ, Dubay DA, Gillespie BW, Moyer AS, Pelletier SJ, Sung RS, Magee JC, Punch JD, Campbell DA Jr, Merion RM. Risk factors for urinary complications after renal transplantation. Am J Transplant. 2007 Jun;7(6):1536-41. doi: 10.1111/j.1600-6143.2007.01790.x. Epub 2007 Apr 8.
- Mangus RS, Haag BW. Stented versus nonstented extravesical ureteroneocystostomy in renal transplantation: a metaanalysis. Am J Transplant. 2004 Nov;4(11):1889-96. doi: 10.1111/j.1600-6143.2004.00595.x.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 07282016
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Kidney Failure, Chronic
-
NCT02857556TerminatedEnd-stage Chronic Kidney Failure
-
NCT01890811Withdrawn
-
NCT01064895TerminatedChronic Kidney Disease | Acute Kidney Injury | Acute Renal Failure | Renal Failure Chronic Contrast Induced
-
NCT01227122UnknownCardiac Surgical Procedures | Preoperative KIDNEY FAILURE, CHRONIC | Postoperative KIDNEY FAILURE, ACUTE
-
NCT02082093Completed
-
NCT00256750CompletedKidney Transplantation | Chronic Kidney Failure
-
NCT00472082TerminatedKidney Transplantation | Chronic Kidney Failure
-
NCT05322291Completed
-
NCT01779557CompletedKidney Failure,Chronic
-
NCT04008953Unknown
Clinical Trials on Magnetic stent
-
NCT00487552TerminatedGastric Outlet Obstruction
-
NCT04384939CompletedKidney Transplantation | Uropathy
-
NCT01131793Completed
-
NCT03387995CompletedTreatment Outcome by Stent-assisted Embolization
-
NCT01560455Completed
-
NCT01054274Unknown
-
NCT04807387Terminated
-
NCT03644017CompletedVenous Stenosis | Venous Occlusion
-
NCT02328898UnknownAcute Coronary Syndrome | Stable Angina Pectoris
-
NCT05200637Not yet recruiting