Automated Oxygen Delivery by O2matic to Patients Admitted With an Exacerbation in COPD (O2MATIC)

January 6, 2019 updated by: Ejvind Frausing Hansen, Hvidovre University Hospital

The aim of the study is to examine if automated oxygen delivery with O2matic is better than manually controlled oxygen therapy for patients admitted to hospital with an exacerbation in Chronic Obstructive Pulmonary Disease (COPD).

O2matic is a closed -loop system based on continuous non-invasive measurement of pulse and oxygen-saturation that is processed in an algorithm that controls the flow of oxygen to the patient.

The primary hypothesis is that O2matic increases time within acceptable oxygen-saturation interval. Secondary hypotheses are that O2matic compared to manual control reduces time with severe hypoxia (SpO2 < 85 %), hypoxi (SpO2 below intended interval) and hyperoxia (SpO2 above intended interval).

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

Closed-loop control of oxygen therapy is described in the literature used for preterm infants, trauma patients, medical emergency use and patients with COPD. For the latter, closed-loop therapy has been used for patients admitted to hospital with an exacerbation, for domiciliary oxygen use and during exercise. O2matic is a closed-loop system that is based on continuous and non-invasive measurement of pulse, oxygen-saturation and respiratory frequency. The algorithm in O2matic controls oxygen delivery with the aim of keeping the saturation within the desired interval, which could be 88-92 % for COPD-patients in accordance with international guidelines on this topic. Saturation interval can be set for the individual patients, as can the range of acceptable oxygen-flow. If saturation or oxygen-flow can't be maintained within the desired intervals an alarm will sound.

All studies on closed-loop systems have shown that this method is better than manually control by nurse to maintain saturation within the desired interval. Furthermore, some studies have indicated that closed-loop has the possibility to reduce admission time and to reduce time spent with oxygen therapy, due to more efficient and fast withdrawal from oxygen supplementation.

In the present study O2matic will be tested versus manual control, for patients admitted with an exacerbation in COPD, and in need of supplemental oxygen. During the study the patients will either have oxygen controlled with O2matic or manually by nursing staff. All patients will have continuous logging of pulse, oxygen-saturation and oxygen-flow with O2matic, but only in the O2matic active group, the algorithm will control oxygen-delivery.

The primary hypothesis will be tested, which is that O2matic is better than manual control for maintaining oxygen-saturation within the desired interval and reducing time with unintended hypoxia and hyperoxia. For this purpose 20 patients will be included in a crossover design with 4 hours of O2matic-controlled oxygen treatment and 4 hours with manually titrated oxygen with a 16 hours washout between periods.

No safety issues has been reported in the literature. Before use O2matic will be approved by The Danish Medicines Agency, The Ethics Committee in the Capital Region of Denmark and by the regional Data Protection Board. The study will be conducted according to GCP standards with independent monitoring. All adverse events and serious adverse events will be monitored and serious adverse events will be reported to Danish Medicines Agency.

Study Type

Interventional

Enrollment (Actual)

20

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Hellerup, Denmark, 2900
        • Gentofte University Hospital
      • Hvidovre, Denmark, 2650
        • Hvidovre University Hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

35 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • COPD verified by FEV1/FVC < 0,70
  • Admission due to exacerbation in COPD
  • COPD exacerbation and pneumonia can be included
  • Duration of admission > 48 hours
  • Need for oxygen supplementation at inclusion (SpO2 <= 88 % without O2 suppl.)
  • Cognitively able to participate in the study
  • Willing to participate and give informed consent.

Exclusion Criteria:

  • Need or anticipated need for mechanical ventilation (except intermittent CPAP)
  • Major co-morbidities (cancer, heart disease, thromboembolic disease, uncontrolled diabetes)
  • Asthma or other respiratory condition requiring higher SpO2 than normal for COPD- patients
  • Pregnancy
  • Acute thromboembolic disease (< 2 weeks)
  • Cognitive barriers for participation

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: RANDOMIZED
  • Interventional Model: CROSSOVER
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
ACTIVE_COMPARATOR: O2matic
Oxygen administered by O2matic. Automatic adjustment based on continuous measurement of SpO2.
Continous measurement of SpO2 during an admission with COPD, and closed-loop control of oxygen-delivery to maintain SpO2 within a target interval.
NO_INTERVENTION: Manual
Oxygen administered by manual control based on nurse's intermittent measurement of SpO2.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Time within SpO2-interval
Time Frame: 4 hours
Fraction of time where SpO2 is kept within desired interval (e.g. 88-92 %) relative to time with SpO2-signal.
4 hours

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Time with severe hypoxia
Time Frame: 4 hours
Fraction of time where SpO2 is below 85 % relative to time with SpO2 signal
4 hours
Time with hypoxia
Time Frame: 4 hours
Fraction of time where SpO2 is below intended interval but not below 85 % relative to time with SpO2 signal
4 hours
Time with hyperoxia
Time Frame: 4 hours
Fraction of time where SpO2 is above intended interval relative to time with SpO2 signal
4 hours

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Collaborators

Investigators

  • Principal Investigator: Ejvind Frausing Hansen, MD, Hvidovre University Hospital, Copenhagen

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (ACTUAL)

May 7, 2018

Primary Completion (ACTUAL)

August 8, 2018

Study Completion (ACTUAL)

August 8, 2018

Study Registration Dates

First Submitted

March 2, 2018

First Submitted That Met QC Criteria

March 7, 2018

First Posted (ACTUAL)

March 14, 2018

Study Record Updates

Last Update Posted (ACTUAL)

January 8, 2019

Last Update Submitted That Met QC Criteria

January 6, 2019

Last Verified

January 1, 2019

More Information

Terms related to this study

Other Study ID Numbers

  • O2MATIC-COPD

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Hypoxia

Clinical Trials on O2matic

Search Similar Trials