Performance of Long-wavelength Autofluorescence Imaging
Performance of Optimized Long-wavelength Fundus Autofluorescence Imaging in Patients With Retinal Diseases
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Fundus autofluorescence (AF) imaging of the retina with confocal scanning laser ophthalmoscopy has been established as a non-invasive imaging modality for the diagnosis of retinal and macular diseases. Long-wavelength near-infrared autofluorescence (excitation: 787 nm, LW-AF) is a new, innovative alternative to the classic autofluorescence imaging using 488 nm blue excitation light. Excitation of the fluorophores at the ocular fundus using a longer wavelength has several advantages. However, with the current imaging technique the autofluorescence signal and thus image quality is considerably lower compared to conventional short-wavelength autofluorescence (SW-AF). This may be the main reason for the currently limited application and scarce scientific publications on this technique.
Therefore, the objective of this study is to assess the performance of an optimized setup of long-wavelength autofluorescence imaging in clinical routine applications. For this purpose, additional laser sources will be integrated into a scanning laser ophthalmoscope and the performance with regards to image quality will be investigated systematically using different excitation wavelengths and filter combinations in healthy controls.
In a next step, the signal intensity will be quantified using an integrated fluorescent reference. First, factors affecting measurements will be identified, followed by generation of a normative database. Subjects with various retinal diseases will then be investigated and compared to the normative database.
Finally, the diagnostic performance of long-wavelength autofluorescence imaging to detect retinal degenerative diseases will be investigated and compared to conventional imaging techniques.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Peter Charbel Issa, DPhil, MD
- Phone Number: +44 1865 234737
- Email: study-enquiry@outlook.com
Study Contact Backup
- Name: Johannes Birtel, MD
- Email: study-enquiry@outlook.com
Study Locations
-
-
-
Oxford, United Kingdom, OX3 9DU
- Oxford Eye Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age 18 years or above
- Defined retinal disease (patients) or no known retinal disease (healthy participants)
- Participants willing to read and understand the study information and provide informed consent
- Participants agree to have some examinations and photographs taken from their eyes
Exclusion Criteria:
- Significant opacities of the ocular media
- difficulties positioning still in front of the camera
- any ocular/ general disease known to affect recordings and/or analysis of retinal images
- Pupil diameter <5mm
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Patients with various retinal diseases
Patients with various retinal diseases will be examined using long-wavelength autofluorescence imaging to assess the performance compared to conventional imaging methods and to quantify the signal compared to a normative database
|
Long-wavelength autofluorescence imaging will be performed with a prototype confocal scanning laser (cSLO) ophthalmoscope which will be equipped with additional laser sources and a reference for quantification of the signal.
The experimental long-wavelength laser sources will be integrated into a custom-modified Spectralis HRA cSLO from Heidelberg Engineering.
The additional laser sources will operate with long wavelength which are less energetic compared to the conventional short-wavelength lasers used currently for routine autofluorescence imaging.
All safety standards have been considered and the light exposure for all imaging modes is well below the exposure limits for Class 1 and Class1M laser products as defined in the standard IEC 60825-1, edition 3.0, 2014-5.
|
|
Experimental: Healthy participants
Healthy participants will be examined using long-wavelength autofluorescence imaging to optimize the signal with additional laser sources and device settings and to compile a normative database for the quantification of the signal.
|
Long-wavelength autofluorescence imaging will be performed with a prototype confocal scanning laser (cSLO) ophthalmoscope which will be equipped with additional laser sources and a reference for quantification of the signal.
The experimental long-wavelength laser sources will be integrated into a custom-modified Spectralis HRA cSLO from Heidelberg Engineering.
The additional laser sources will operate with long wavelength which are less energetic compared to the conventional short-wavelength lasers used currently for routine autofluorescence imaging.
All safety standards have been considered and the light exposure for all imaging modes is well below the exposure limits for Class 1 and Class1M laser products as defined in the standard IEC 60825-1, edition 3.0, 2014-5.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Performance of long-wavelength autofluorescence imaging
Time Frame: 1 day
|
The sensitivity and specificity to detect characteristics in retinal diseases will be investigated in patients with various retinal diseases and compared to conventional imaging methods
|
1 day
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Optimization of the signal of long-wavelength autofluorescence imaging using different laser and filter settings
Time Frame: 1 day
|
To optimize the signal of long-wavelength autofluorescence imaging, the fluorescence intensity of the different laser sources and filter settings will be assessed.
|
1 day
|
|
Quantification of the optimized signal of long-wavelength autofluorescence imaging in healthy controls and participants with various retinal diseases
Time Frame: 1 day
|
To quantify the optimized signal of long-wavelength autofluorescence imaging the absolute fluorescence intensity compared to a fluorescent reference will be assessed in patients with various retinal diseases and compared to healthy controls
|
1 day
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Peter Charbel Issa, DPhil, MD, Oxford Eye Hospital, The West Wing John Radcliffe Hospital Oxford, OX3 9DU
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 13703
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Retinal Degeneration
-
NCT02960828UnknownAge-Related Macular Degeneration | Retinal Drusen
-
NCT01269151CompletedAge-Related Macular Degeneration | Retinal Function
-
NCT07605468Not yet recruiting
-
NCT03946085CompletedMacular Degeneration | Age-related Macular Degeneration | Retinal Drusen
-
NCT02569892CompletedMacular Degeneration | Retinal Drusen
-
NCT02717026CompletedAge-Related Macular Degeneration | Retinal Blood Vessels
-
NCT04882956RecruitingMacula Lutea Degeneration
-
NCT05211804CompletedWet Macular Degeneration
-
NCT02305238Completed
Clinical Trials on Long-wavelength autofluorescence imaging
-
NCT03139942CompletedColonic Diseases | Colonic Polyp | Colonic Neoplasms | Colonic Cancer | Colonic Adenocarcinoma | Colonic Adenoma | Colonic Carcinoma | Colonic Dysplasia | Colon Hyperplastic Polyp
-
NCT07617584Not yet recruitingThyroid Diseases | Hypocalcemia | Goiter, Nodular | Thyroid Nodule | Hypoparathyroidism | Thyroidectomy
-
NCT07338461Not yet recruitingDiabetic Retinopathy | Age Related Macular Degeneration | Normal Eyes | Eyes With Retinal Diseases
-
NCT06927245Not yet recruitingThyroid Surgery | Inadvertent Parathyroidectomy | Enlarged Thyroid
-
NCT06068972CompletedNon-Healing Ulcer of Skin | Autofluorescence Imaging
-
NCT07327684RecruitingMetabolic Syndrome | Insulin Resistance
-
NCT07060196Not yet recruitingAMD - Age-Related Macular Degeneration
-
NCT03517241UnknownRetina Disorder | Macula; Degeneration, Congenital or Hereditary
-
NCT02863640Terminated