Quality Control of CE-Certified Phonak Hearing Aids - Sonova2018_05
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Zürich
-
Stäfa, Zürich, Switzerland, 8712
- Sonova AG
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Adult hearing impaired persons (minimum age: 18 years, mild to moderate Hearing loss) without hearing aid experience
- Good written and spoken (Swiss) German language skills
- Healthy outer ear
- Ability to fill in a questionnaire (p/eCRF) conscientiously
- willingness to wear Receiver in the canal hearing aids
- Informed Consent as documented by signature
- owning an iPhone 6 or higher
Exclusion Criteria:
- Contraindications to the MD in this study, e.g. known hypersensitivity or allergy to the investigational product
- Limited mobility and not in the position to attend weekly appointments in Stäfa (Switzerland)
- Limited ability to describe listening impressions/experiences and the use of the hearing aid
- Inability to produce a reliable hearing test result
- Known psychological problems
- Central hearing disorders
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Phonak Audéo B90-Direct
The Phonak Audéo B90-Direct is the most recent Receiver-in-the-canal Hearing aid with direct connectivity functionality from Phonak which will be fitted to the participants individual Hearing loss.
|
The Phonak Audéo B90-Direct is the most recent Receiver-in-the-canal Hearing aid from Phonak which will be fitted to the participants individual Hearing loss.
|
|
Active Comparator: HearingAid_A
HearingAid_A is the most recent Receiver-in-the-canal Hearing aid with direct connectivity functionality from manufacturer_A which will be fitted to the participants individual Hearing loss.
|
HearingAid_A is the most recent Receiver-in-the-canal Hearing aid from manufacturer_A which will be fitted to the participants individual Hearing loss.
|
|
Active Comparator: HearingAid_B
HearingAid_B is the most recent Receiver-in-the-canal Hearing aid with direct connectivity functionality from manufacturer_B which will be fitted to the participants individual Hearing loss.
|
HearingAid_B is the most recent Receiver-in-the-canal Hearing aid from manufacturer_B which will be fitted to the participants individual Hearing loss.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Comparison of the speech intelligibiltity of phone calls via direct streaming
Time Frame: 6 weeks
|
The primary outcome meaurement of this study is the comparison of Phonak's direct connectivity solution against two competitors in terms of subjective speech intelligibility of streamed audio signals via smartphone.
The subjective speech intelligibilty will be measured via interview (sound quality rating, satisfaction rating of speech intelligibility) from far-end talker and near-end talker.
|
6 weeks
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Investigation of Bluetooth Connection losses between Hearing Aid and smart phone during a phone call (number of reported interruptions during a phone call which will be streamed via bluetooth from Smartphone to Hearing Aid)
Time Frame: 6 weeks
|
The secondary outcome measurement of this study is to investigate the number of (Bluetooth-) Connection losses between Hearing Aid and Smartphone during a phone call stream.
The bluetooth connection losses will be investigated by counting the reported interruptions of a streamed phone call between smartphone and Hearing Aid in relation to the amount of conducted phone calls during two weeks of home trial for the investigational device and the comparative devices.
|
6 weeks
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Comparison of the subjective Sound Quality rating of TV-Audiostream via direct connectivity
Time Frame: 6 weeks
|
Another outcome measurement of this study is the comparison of streamed audio signals from TV in terms of sound quality (measured via satisfaction rating).
|
6 weeks
|
|
Comparison of the Usability of remote controls via direct connectivity
Time Frame: 6 weeks
|
Another outcome measurement of this study is the comparison of the usability of a remote control via interview during and after home trial.
|
6 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Sonova2018_05
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Hearing Loss, Sensorineural
-
NCT05154188Not yet recruitingSensorineural Hearing Loss, Bilateral | Sensorineural Hearing Loss, Severe | Sensorineural Hearing Loss, Profound
-
NCT06699797Active, not recruitingSensorineural Hearing Loss | Sensorineural Hearing Loss (Disorder) | Sensorineural Hearing Loss, Bilateral | Sensorineural Hearing Loss, Severe | Sensorineural Hearing Loss, Profound | Sensori-Neural Deafness
-
NCT01529333UnknownMixed Conductive and Sensorineural Hearing Loss, Bilateral
-
NCT03509974CompletedUnilateral Mixed Conductive and Sensorineural Hearing Loss (Diagnosis) | Sensorineural Hearing Loss, Unilateral With Normal Hearing on the Contralateral Side
-
NCT04108598UnknownSensorineural Hearing Loss | Sensory Hearing Loss | Sensorineural Hearing Loss in Left Ear | Sensorineural Hearing Loss in Right Ear | Sensorineural Hearing
-
NCT05300230RecruitingBilateral Sensorineural Hearing Loss | Unilateral Sensorineural Hearing Loss
-
NCT05196022RecruitingHearing Loss, Unilateral | Cochlear Implants | Hearing Loss, Sensorineural, Severe | Hearing Loss, Sensorineural, Bilateral | Hearing Loss, Sensorineural, Profound
-
NCT06997406Not yet recruitingTinnitus | Sudden Sensorineural Hearing Loss (SSNHL)
-
NCT06878599Not yet recruitingSudden Sensorineural Hearing Loss (SSNHL)
-
NCT02809118TerminatedHearing Loss, Idiopathic Sudden Sensorineural
Clinical Trials on Phonak Audéo B90-Direct
-
NCT03755453Completed
-
NCT03718975CompletedHearing Loss | Sensorineural Hearing Loss
-
NCT03379766CompletedHearing Loss, Sensorineural
-
NCT03131557CompletedHearing Loss, Bilateral Sensorineural, Progressive
-
NCT03780374Completed
-
NCT03253003CompletedHearing Loss, Bilateral Sensorineural, Progressive
-
NCT06420037CompletedHearing Loss, Sensorineural | Speech Intelligibility