Peri-Implant Healing Around Two Different Machined-Collar Designs After 25 Years of Function
Prospective Randomised Clinical Trial Evaluating the Effects of Two Different Implant Collar Designs on Peri-Implant Healing and Functional Osseointegration After 25 Years of Function With Full Arch Mandibular Prostheses
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Quebec
-
Montreal, Quebec, Canada, H3C 3J7
- Université de Montréal
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- non-smoker
- no temporomandibular joint (TMJ) disorder or facial pain
- having participated in the original study (1993 - 1996) at which time the minimum participants' age was 25 years and the maximum 56 years
Exclusion Criteria:
- refusal to sign informed consent documents
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1 (Configuration 1)
Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at one site
|
Brånemark® implant placed at sites 2 (left medial) and 5 (right distal), Swede-Vent® implant placed at sites 1 (left distal) and 4 (right medial), Screw-Vent® implant placed at site 3 (para symphysis)
|
|
Experimental: Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2 (Configuration 2)
Device placement: B (Brånemark® dental implant) placed at one site, SW (Swede-Vent® dental implant) placed at two sites, SC (Screw-Vent® dental implant) placed at two sites
|
Brånemark® implant placed at site 3 (para symphysis), Swede-Vent® implant placed at sites 2 (left medial) and 5 (right distal), Screw-Vent® implant placed at sites 1 (left distal) and 4 (right medial)
|
|
Experimental: Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2 (Configuration 3)
Device placement: B (Brånemark® dental implant) placed at two sites, SW (Swede-Vent® dental implant) placed at one site, SC (Screw-Vent® dental implant) placed at two sites
|
Brånemark® implant placed at sites 1 (left distal) and 4 (right medial), Swede-Vent® implant placed at site 3 (para symphysis), Screw-Vent® implant placed at sites 2 (left medial) and 5 (right distal)
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Comparison of Distance Between First Bone to Implant Contact Point (fBIC) and Microgap (MG), After 25 Years of Function, Between All B, All SW, and All SC Dental Implant Units in All Three Configurations
Time Frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Distance between first bone-to-implant contact point (fBIC) and microgap (MG) at the crest was measured (mm) at mesial and distal sides of each implant/abutment complex on conventional peri-apical radiographs using a standardized equipment and measurement protocol (Camarda, et al., 2018) after 25 years of function.
Values fBIC-MG (Mean ± SE) ("-" for bone loss) were calculated, recorded and compared between all B and all SW, between all B and all SC and between all SW and all SC dental implant units in all three Configurations
|
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Comparison of Prosthesis, Abutment, and Implant Mobility or Looseness: Absence (0) or Presence (1) of Mobility or Looseness After 25 Years of Function
Time Frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Mobility was measured by applying manual pressure on the handles of two instruments, each placed on opposite sides of the prostheses and abutments, and was recorded as 0 (no mobility or looseness) or 1 (mobility or looseness).
Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
|
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
|
Comparison of Soft Tissue Healing: Height (mm) of Keratinized Tissue After 25 Years of Function
Time Frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Height of the keratinized tissue was measured (mm) using a ColorVue UNC12 Hu-Friedy probe on the buccal and lingual implant/abutment surfaces.
Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
|
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
|
Comparison of Soft Tissue Healing: Probing Depth (mm) After 25 Years of Function
Time Frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Using a ColorVue UNC12 Hu-Friedy probe, probing depth was measured (mm) on the buccal, lingual, mesial and distal implant/abutment surfaces.
Values (Mean ± SE) were calculated, recorded and compared between B and SW, between B and SC and between SW and SC for Configuration 1(Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent ®1, Screw-Vent® 2)
|
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
|
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Plaque and/or Gingival Bleeding After 25 Years of Function
Time Frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Absence (0) or presence (1) of plaque and/or gingival bleeding on probing was evaluated using the dichotomous/binary plaque index (dPI) (Galgut, P. A., 1999) and bleeding index (dBI), respectively (Galgut, P.A., 1999).
Values (Mean ± SE) were compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent ®1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
|
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
|
Comparison of Soft Tissue Healing: Absence (0) or Presence (1) of Purulent Exudate After 25 Years of Function
Time Frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Absence (0) or presence (1) of purulent exudate on probing was evaluated.
Values (Mean ± SE) were recorded, and compared between B and SW, between B and SC and between SW and SC for Configuration 1 (Brånemark® 2, Swede-Vent® 2, Screw-Vent® 1), Configuration 2 (Brånemark® 1, Swede-Vent® 2, Screw-Vent® 2), and Configuration 3 (Brånemark® 2, Swede-Vent® 1, Screw-Vent® 2)
|
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Comparison of Two Measurement Systems Used to Evaluate Peri-implant Bone Healing After 25 Years of Function
Time Frame: After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Conventional peri-apical radiology and phosphor-plate digital technology (Digora System™, Digora OptimeTM, Sporedex Dental Co., Tuusula, Finland) were used with the standardized equipment to take peri-apical radiographs on 95 implant/abutment units (Camarda, et al., 2018; Bhaskaran, et al., 2005).
Following calibration, the distance between the first-bone-to-implant-contact-point and the crestal-microgap (fBIC-MG) was measured (mm) at the mesial and distal aspects of each implant/abutment unit after 25 years of function.
Values (Mean ± SE) fBIC-MG were recorded for each of the two measurement systems.
ICC (Intraclass Correlation Coefficient, two-way, mixed effect model) and Bland-Altman Limits of agreement (Bland & Altman, 1986) were used to evaluate the level of agreement between the two systems
|
After 25 years (24.6 ± 0.19 years, mean ± SE) of function
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Aldo J Camarda, DDS, MSc, Université de Montréal
- Principal Investigator: Robert Durand, DMD, MSc, Université de Montréal
- Principal Investigator: Marwa Benkarim, Université de Montréal
- Principal Investigator: Pierre Rompré, MSc, Université de Montréal
- Principal Investigator: Geneviève Guertin, DMD, MSc, Université de Montréal
- Study Director: Hugo Ciaburro, DMD, MSc, Université de Montréal
Publications and helpful links
General Publications
- Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.
- Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants. 1986 Summer;1(1):11-25. No abstract available.
- Adell, R. (1987). Long-term treatment results. In: Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 175-285). Quintessence Publishing Co. Inc.
- Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52(2):155-70. doi: 10.3109/17453678108991776.
- Bhaskaran V, Qualtrough AJ, Rushton VE, Worthington HV, Horner K. A laboratory comparison of three imaging systems for image quality and radiation exposure characteristics. Int Endod J. 2005 Sep;38(9):645-52.
- Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983 Sep;50(3):399-410. doi: 10.1016/s0022-3913(83)80101-2. No abstract available.
- Brånemark P-I. (1987). Introduction to osseointegration. In Brånemark, P-I., Zarb, G.A., Albrektsson, T. (Eds.). Tissue-integrated prostheses: osseointegration in clinical dentistry (pp. 11-76). Quintessence Publishing Co. Inc.
- De Bruyn H, Collaert B, Linden U, Flygare L. A comparative study of the clinical efficacy of Screw Vent implants versus Branemark fixtures, installed in a periodontal clinic. Clin Oral Implants Res. 1992 Mar;3(1):32-41. doi: 10.1034/j.1600-0501.1992.030106.x.
- Galgut P. A comparison of different indices used in the clinical assessment of plaque and gingival bleeding. Clin Oral Investig. 1999 Jun;3(2):96-9. doi: 10.1007/s007840050085.
- Niznick, G. A. (1989). Open letters no. 1 and no. 2 to the dental profession, Core-Vent Corporation Newsletter and manufacturer's product description. Encino, California USA.
- Camarda AJ, Durand R, Benkarim M, Rompre PH, Guertin G, Ciaburro H. Prospective randomized clinical trial evaluating the effects of two different implant collar designs on peri-implant healing and functional osseointegration after 25 years. Clin Oral Implants Res. 2021 Mar;32(3):285-296. doi: 10.1111/clr.13699. Epub 2021 Jan 25.
- Camarda AJ, Milot P, Ciaburro H, Rompre PH, Sallaleh I, Do CMA. Long-term randomized clinical trial evaluating the effects of fixture surface acid-etching and machined collar design on bone healing. Quintessence Int. 2018;49(9):733-743. doi: 10.3290/j.qi.a41013.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CERC-19-015-P
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.