Elimination of CO2-insufflation-induced Hypercarbia in Open Heart Surgery
Elimination of CO2-insufflation-induced Hypercarbia in Open Heart Surgery Using a Separate Reservoir for Suction of Blood From the Open Surgical Wound
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Background: CO2-gas insufflation is used for continuous de-airing during open heart surgery. The study aim was to evaluate if an additional separate venous reservoir eliminates CO2-insufflation induced hypercapnea and keeps sweep gas flow of the oxygenator constant.
Methods: A separate small reservoir are used during CPB in addition to a standard large venous reservoir. The small reservoir receive drained wound blood and CO2-gas continuously via a suction drain (1 L/min) and handheld suction devices from the open surgical wound. CO2-gas is insufflated via a gas-diffuser in the open surgical wound at 10 L/min. During cross-clamping, gas and blood are either continuously drained to the standard large venous reservoir or not, every 5 minutes after steady state of PaCO2 is observed, after adjustment of sweep gas flow as necessary. Mean values for each setup (2-4 times) for each patient will be analyzed with Wilcoxon rank-sum test.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Jan van der Linden, MD, PhD
- Phone Number: +468-51770121
- Email: jan.vanderlinden@ki.se
Study Locations
-
-
-
Stockholm, Sweden
- Recruiting
- Karolinska University Hospital
-
Contact:
- Jan van der Linden, MD, PhD
- Email: jan.vanderlinden@ki.se
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- adult patients undergoing open heart replacement of the aortic valve
- Use of perioperative cardiopulmonary bypass
Exclusion Criteria:
- Denied participation in the study
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Non-Randomized
- Interventional Model: Crossover Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
No Intervention: conventional setup
Blood and gas from the coronary and cardiotomy suction devices is continuously evacuated via the additional reservoir to the standard reservoir.
|
|
|
Experimental: Intervention setup
The connecting tube between the additional and standard venous reservoir is clamped.
Thus, blood and gas from the coronary and cardiotomy suction devices are collected in the additional venous reservoir.
During the intervention setup, the blood in the additional venous reservoir is only evacuated to the standard reservoir if the volume exceeded 800ml, and always with a remaining volume of 100 mL blood to keep the CO2-gas trapped in the additional venous reservoir.
|
Clamping of the tube between the additional and standard venous reservoir
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Difference in PaCO2 (kPa)
Time Frame: At 5 minutes steady state
|
At 5 minutes steady state
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Oxygenator sweep gas flow rate (L/min)
Time Frame: At 5 minutes steady state
|
At 5 minutes steady state
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2018/1091-31
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Adult Patients Undergoing Open Heart Replacement of the Aortic Valve for Aortic Stenosis or Insufficiency
-
NCT02219815CompletedPatients Waiting for Combined Procedures. (CAGB and Valve) | Patients Waiting for Coronary Artery Bypass Graft Surgery | Patients Waiting for Aortic Valve Repair or Replacement | Patients Waiting for Mitral Valve Repair or Replacement
-
NCT07129421Not yet recruitingAortic Valve Replacement | Aortic Valve Regurgitation | AORTIC VALVE DISEASES | Aortic Valve Stenosis and/or Insufficiency
-
NCT06953206Not yet recruitingAortic Insufficiency | Transcatheter Aortic Valve Replacement (TAVR) | Aortic-Stenosis | Degenerative Valve Disease
-
NCT03686527CompletedMyocardial Function of the Stenosis Aortic Valve Before and Beyond Valve Replacement
-
NCT05310461RecruitingAortic Valve Replacement in Patients With Moderate Aortic Stenosis Combined With Mitral Regurgitation
-
NCT02664649CompletedSymptomatic Aortic Stenosis | Eligible for Transcatheter Aortic Valve Replacement
-
NCT07489313CompletedValvular Heart Disease Patients | Aortic or Mitral Valve Replacement
-
NCT05295628Active, not recruitingAortic Valve Stenosis | Aortic Valve Disease | Aortic Valve Insufficiency | Aortic Valve Replacement
-
NCT02713932UnknownAortic Valve Stenosis | Aortic Valve Insufficiency | Transcatheter Aortic Valve Replacement
-
NCT07267117RecruitingAortic Valve Stenosis | Aortic Valve Disease | Mitral Valve Stenosis | Heart Valve Disease | Tricuspid Valve Regurgitation | Mitral Valve Disease | Aortic Valve Regurgitation | Transcatheter Valve Replacement | Tricuspid Valve Disease | Transcatheter Pulmonary Valve Replacement (TPVR)
Clinical Trials on Tube clamping
-
NCT04159220Completed
-
NCT02727517CompletedAsphyxia Neonatorum | Neonatal Disorder
-
NCT02222805CompletedEffect of Timing of Umbilical Cord Clamping on Anaemia at 8 and 12 Months and Later NeurodevelopmentAnemia | Iron Deficiency | Neonatal Jaundice
-
NCT04600674RecruitingRhesus Isoimmunization
-
NCT03549884CompletedElective Cesarean Section | Umbilical Cord Management
-
NCT01222364CompletedInfant, Small for Gestational Age | Infant, Premature | Infant, Low Birth Weight | Infant, Newborn
-
NCT04369313RecruitingGestational Diabetes Mellitus | Neonatal Hyperbilirubinemia | Neonatal Asphyxia
-
NCT00840983CompletedNecrotizing Enterocolitis | Intraventricular Hemorrhage | Bronchopulmonary Dysplasia | Motor Skills Disorders | Late Onset Neonatal Sepsis