Safety and Efficacy of NTX-001 Compared to SOC in Acute Single Peripheral Nerve Injuries
Phase 2a, Multicenter, Randomized, Patient and Evaluator Blinded, Controlled Study Evaluating the Safety and Efficacy of NTX-001 Compared to SOC in the Treatment of Acute Single Transected Peripheral Nerve Injury Occurring Below the Distal Border of the Brachial Plexus Requiring Surgical Repair.
NTX-001 is a single use surgical product intended for use in conjunction with standard suture neurorrhaphy of severed nerves in patients between 16 and 80 years of age.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
NTX-001 (Product) is a surgical product that consists of an active solution (drug), an isolation chamber medical device (chamber or device) and two (2) other sterile solutions.
NTX-001 has been developed as a surgical product to be used in conjunction with standard suture neurorrhaphy of a severed nerve. Use of NTX-001 is intended to safely accelerate the often slow and diminished return of function in repaired nerves. It often takes months and/or years to determine if function will be restored. By that point, restoration is often incomplete and can result in lifelong motor and/or sensory deficits. By reconnecting (PEG-fusion) a substantial number of axons within a severed nerve, the degeneration-regeneration cycle and subsequent atrophy may be reduced or even prevented for those axons and their targets, respectively. NTX-001 (PEG-fusion) has the potential to avoid the consequences of protracted denervation of distal target tissues by eliminating the period of total denervation thus reducing the time to stable recovery and providing greater innervation to affected tissues.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 2
Contacts and Locations
Study Locations
-
-
Florida
-
Gainesville, Florida, United States, 32607
- UF Health - University of FL - Gainesville
-
Orlando, Florida, United States, 32806
- Orlando Health
-
-
Illinois
-
Chicago, Illinois, United States, 60637
- University of Chicago
-
-
Indiana
-
Indianapolis, Indiana, United States, 46260
- Indiana Hand to Shoulder Center
-
-
Maryland
-
Baltimore, Maryland, United States, 21224
- Johns Hopkins Bayview Medical Center
-
Baltimore, Maryland, United States, 21218
- Curtis National Hand Center
-
-
Missouri
-
St Louis, Missouri, United States, 63110
- Washington University
-
-
Ohio
-
Columbus, Ohio, United States, 43202
- The Ohio State University Wexner Medical Center Hand and Upper Extremity Center
-
-
Virginia
-
Richmond, Virginia, United States, 23398
- Virginia Commonwealth University
-
-
Washington
-
Seattle, Washington, United States, 98107
- Harborview Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- The subject is at least 12 years of age and not older than 80.
- The subject has sustained a confirmed (intra-op assessment) single transected peripheral nerve injury.
- The subject's nerve injury is classified as Sunderland's Fourth and Fifth Degree (Class III)
- The subject's nerve injury is amenable to minimal or acceptable tension, in direct, end-to-end repair.
- The surgical repair will occur within 48 hours of injury.
Exclusion Criteria:
- The subject has a PNI with a segmental loss (gap) that cannot be repaired with minimal or acceptable tension.
- Other treatments known to affect the growth and/or physiology of the neural and vascular system.
- The nerve injury has vascular damage that cannot be repaired to provide adequate perfusion of the injured site.
- The subject is pregnant and/or is breastfeeding.
- The subject has a significant medical comorbidity precluding immediate repair.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: NTX-001
NTX-001 used during surgical repair of an upper extremity peripheral nerve injury in conjuction with standard suture neurorrhaphy. |
One time use surgical product, 3 solutions applied topically, in sequence, to the peripheral nerve repair site, in conjunction with standard suture neurorrhaphy. An isolation chamber medical device (device) is utilized to focus the application of PEG (Solution #2) on the coapted nerve for the required amount of exposure time.
Other Names:
|
|
No Intervention: Standard of Care
standard suture neurorrhaphy |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change From Baseline Michigan Hand Questionnaire Total Score (MHQ)
Time Frame: Baseline and Week 12
|
The MHQ measures hand function and is scored from 0-100; with 100 being the "best" score. |
Baseline and Week 12
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Responder Analysis for % Recovery of MHQ Total Score > Than or = to 75% Cutoff
Time Frame: Baseline, Weeks 8, 12, 24, 48
|
The MHQ measures hand function and is scored from 0-100; with 100 being the "best" score. |
Baseline, Weeks 8, 12, 24, 48
|
|
Change From Baseline Numeric Pain Rating Scale (NPRS)
Time Frame: Baseline and at Weeks 4, 8, 12, 24, 36 and 48
|
The NPRS measures pain intensity on a scale from 0 representing no pain and 10 to the worst pain as bad as you can imagine. |
Baseline and at Weeks 4, 8, 12, 24, 36 and 48
|
|
Number of Responders to Modified British Medical Research Council (MMRC) Sensory Grading (S0-S4)
Time Frame: Baseline, Weeks 4, 8, 12, 24, 36 and 48
|
The MMRC sensory grading scale was used to assess sensory recovery based on pain/touch sensibility and static and moving two-point discrimination testing (STPD and MTPD). The scale ranges from S0 to S4, where S0 = no sensory recovery; S1 = recovery of deep cutaneous pain sensibility; S2 = recovery of some superficial pain and tactile sensibility; S3 = recovery of pain and tactile sensibility with imperfect localization and two-point discrimination; and S4 = complete sensory recovery. Higher scores indicate better sensory recovery. A responder was defined as a participant achieving a sensory recovery grade of S3 or greater (S3+). Data presented are the percentage of participants who met the S3+ responder criterion at each assessment time point. |
Baseline, Weeks 4, 8, 12, 24, 36 and 48
|
|
Number of Responders to Modified British Medical Research Council (MMRC) Motor Grading (M0-M5)
Time Frame: Baseline, Weeks 4, 8, 12, 24, 36 and 48
|
The MMRC motor grading scale was used to assess motor recovery. Motor function was evaluated on an ordinal scale ranging from M0 to M5, where M0 indicates no muscle contraction and M5 indicates normal muscle strength. Grades were defined as follows: M0 = no contraction; M1 = muscle contraction without joint movement; M2 = active movement with gravity eliminated; M3 = active movement against gravity; M4 = active movement against resistance; and M5 = normal muscle strength. Higher scores indicate better motor recovery. A responder was defined as a participant achieving a motor function score of M3 or greater (M3+). Data presented are the percentage of participants meeting the M3+ responder criterion at each assessment time point. |
Baseline, Weeks 4, 8, 12, 24, 36 and 48
|
|
Number of Responders to Semmes-Weinstein Monofilament Test (SWMT)
Time Frame: Baseline, Weeks 4, 8, 12, 24, 36 and 48
|
The Semmes-Weinstein Monofilament Test (SWMT) was used to assess sensory function of the affected nerve. A responder was defined as a participant with a return to normal gauge sensation (2.83 g) for the affected nerve. Lower scores indicate better sensory function, with 2.83 g corresponding to normal sensation. Data presented are the percentage of participants who met the responder criterion at each assessment time point. |
Baseline, Weeks 4, 8, 12, 24, 36 and 48
|
|
Change From Baseline Cold Intolerance Symptom Severity (CISS)
Time Frame: Baseline and at Weeks 4, 8, 12, 24 and 48
|
The CISS focuses on the impact of cold intolerance on activities of daily life; the score ranges a score between 0 and 100, where 0 is no symptoms at all and 100 is the most severe symptoms you can possibly imagine. |
Baseline and at Weeks 4, 8, 12, 24 and 48
|
|
Number of Responders to Patient Global Impression of Change (PGIC)
Time Frame: Baseline, Weeks 4, 8, 12, 24 and 48
|
The Patient Global Impression of Change (PGIC) is a patient-reported assessment of overall change in health status since treatment initiation. Participants rate their condition on a 7-point scale: 1 = very much worse, 2 = much worse, 3 = minimally worse, 4 = no change, 5 = minimally improved, 6 = much improved, and 7 = very much improved. Higher scores indicate greater perceived improvement. A responder was defined as a participant with a PGIC score of 5 or greater. Data presented are the percentage of participants who met the responder criterion at each assessment time point. |
Baseline, Weeks 4, 8, 12, 24 and 48
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change From Baseline in Michigan Hand Questionnaire (MHQ) Activities of Daily Living
Time Frame: Baseline and at Weeks 8, 12, 24, 48
|
The MHQ Two Domain Score analyses consisted of the average of the domain Activities of Daily Living (ADL). MHQ Activities of Daily Living normalized score ranges from 0 to 100, with 0 being the worst score and 100 the best. |
Baseline and at Weeks 8, 12, 24, 48
|
|
Change From Baseline in MHQ Pain Score
Time Frame: Baseline and at Weeks 8, 12, 24, 48
|
The MHQ Two Domain Score analyses consisted of the average of the pain domain. MHQ Pain normalized score ranges from 0 to 100, with 0 being the best score and 100 the worst. |
Baseline and at Weeks 8, 12, 24, 48
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Seth Schulman, MD, Neuraptive Therapeutics Inc.
Publications and helpful links
General Publications
- Ghergherehchi CL, Mikesh M, Sengelaub DR, Jackson DM, Smith T, Nguyen J, Shores JT, Bittner GD. Polyethylene glycol (PEG) and other bioactive solutions with neurorrhaphy for rapid and dramatic repair of peripheral nerve lesions by PEG-fusion. J Neurosci Methods. 2019 Feb 15;314:1-12. doi: 10.1016/j.jneumeth.2018.12.015. Epub 2018 Dec 23.
- Mikesh M, Ghergherehchi CL, Louis Hastings R, Ali A, Rahesh S, Jagannath K, Sengelaub DR, Trevino RC, Jackson DM, Bittner GD. Corrigendum to "Polyethylene glycol solutions rapidly restore and maintain axonal continuity, neuromuscular structures, and behaviors lost after sciatic nerve transections in female rats.". J Neurosci Res. 2018 Sep;96(9):1623. doi: 10.1002/jnr.24277. No abstract available.
- Mikesh M, Ghergherehchi CL, Rahesh S, Jagannath K, Ali A, Sengelaub DR, Trevino RC, Jackson DM, Tucker HO, Bittner GD. Corrigendum to "Polyethylene glycol treated allografts not tissue matched nor immunosuppressed rapidly repair sciatic nerve gaps, maintain neuromuscular functions, and restore voluntary behaviors in female rats". J Neurosci Res. 2018 Sep;96(9):1624. doi: 10.1002/jnr.24278. No abstract available.
- Bittner GD, Spaeth CS, Poon AD, Burgess ZS, McGill CH. Repair of traumatic plasmalemmal damage to neurons and other eukaryotic cells. Neural Regen Res. 2016 Jul;11(7):1033-42. doi: 10.4103/1673-5374.187019.
- Bittner GD, Sengelaub DR, Trevino RC, Peduzzi JD, Mikesh M, Ghergherehchi CL, Schallert T, Thayer WP. The curious ability of polyethylene glycol fusion technologies to restore lost behaviors after nerve severance. J Neurosci Res. 2016 Mar;94(3):207-30. doi: 10.1002/jnr.23685. Epub 2015 Nov 3.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- NTx20201
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.