ILM Inverted Flap Size in Macular Hole
Impact of the Inverted Internal Limiting Membrane Flap Diameter on Idiopathic Macular Hole Closure: Comparative Randomized Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Dakahelia
-
Mansoura, Dakahelia, Egypt, 35516
- Ophthalmic center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Eyes with stage 4 idiopathic MHs with a diameter >250µm on spectral domain optical coherence tomography (SD-OCT)
Exclusion Criteria:
- traumatic MH
- myopic MHs,
- MH secondary to retinal detachment,
- long-standing MH> 12 months
- previous retinal surgeries
- high myopia with an axial length > 26.0 mm
- other ocular pathologies interfering with the interpretation of the OCT reports.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: small flap medium-sized macular hole (SFMM)
small flap (1-2 disc-diameter) was performed in medium sized macular hole (250-400 um)
|
Complete vitrectomy was done with the aid of triamcinolone acetonide followed by fluid-air exchange.
Staining of the ILM was carried with 0.05% solution of Brilliant Blue dye (BBG), (Ocublue plus, Aurolab, India) for 30 seconds, ILM peeling was proceeded leaving a circle of ILM measuring approximately 1-2 DD in SF groups and >2 to 4DD in LF group, centered around the MH.
The ILM outside the parafoveal area was peeled to the arcade.
The ILM around the hole was then detached from the retina up to the edge of the hole.
The ILM flap around the edge of the hole was inverted over the MH using a scraper.
|
|
Active Comparator: large flap medium-sized macular hole (LFMM)
large flap (3-4 disc-diameter) was performed in medium sized macular hole (250-400 um)
|
Complete vitrectomy was done with the aid of triamcinolone acetonide followed by fluid-air exchange.
Staining of the ILM was carried with 0.05% solution of Brilliant Blue dye (BBG), (Ocublue plus, Aurolab, India) for 30 seconds, ILM peeling was proceeded leaving a circle of ILM measuring approximately 1-2 DD in SF groups and >2 to 4DD in LF group, centered around the MH.
The ILM outside the parafoveal area was peeled to the arcade.
The ILM around the hole was then detached from the retina up to the edge of the hole.
The ILM flap around the edge of the hole was inverted over the MH using a scraper.
|
|
Active Comparator: small flap large-sized macular hole (SFLM)
small flap (1-2 disc-diameter) was performed in Large sized macular hole (>400 um)
|
Complete vitrectomy was done with the aid of triamcinolone acetonide followed by fluid-air exchange.
Staining of the ILM was carried with 0.05% solution of Brilliant Blue dye (BBG), (Ocublue plus, Aurolab, India) for 30 seconds, ILM peeling was proceeded leaving a circle of ILM measuring approximately 1-2 DD in SF groups and >2 to 4DD in LF group, centered around the MH.
The ILM outside the parafoveal area was peeled to the arcade.
The ILM around the hole was then detached from the retina up to the edge of the hole.
The ILM flap around the edge of the hole was inverted over the MH using a scraper.
|
|
Active Comparator: large flap Large-sized macular hole (LFLM)
large flap (3-4 disc-diameter) was performed in large sized macular hole (>400 um)
|
Complete vitrectomy was done with the aid of triamcinolone acetonide followed by fluid-air exchange.
Staining of the ILM was carried with 0.05% solution of Brilliant Blue dye (BBG), (Ocublue plus, Aurolab, India) for 30 seconds, ILM peeling was proceeded leaving a circle of ILM measuring approximately 1-2 DD in SF groups and >2 to 4DD in LF group, centered around the MH.
The ILM outside the parafoveal area was peeled to the arcade.
The ILM around the hole was then detached from the retina up to the edge of the hole.
The ILM flap around the edge of the hole was inverted over the MH using a scraper.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
rate of macular hole closure
Time Frame: 6 months
|
defined as the proportion of the eyes with complete MH closure based on SD-OCT findings
|
6 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
BCVA
Time Frame: 6 months
|
best corrected visual acuity
|
6 months
|
|
timing of MH closure
Time Frame: 6 months
|
the time of complete macular hole closure
|
6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- ILM flap size
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.