Noble Meta Alloy Coated Catheters in Patients With Long Term Catheterization
Noble Metal Alloy Coated Versus Silicone Foley Catheter in Patients With Long Term Catheterization: A Prospective Randomized Controlled Study
Eighty percent of nosocomial UTI caused by indwelling urinary catheters and so known-as catheter-associated UTI. CAUTI leads to multiple local and systemic derangements such as suprapubic pain, dysuria, cystitis, pyelonephritis, septicemia, and even septic shock.
This study will be conducted up on 100 patients (50 per each group) with long term catheterization to assess efficacy of noble metal alloy coated catheter in reducing CAUTI.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
This prospective controlled randomized study conducted upon 100 patients at Alexandria University hospital from 21 May 2020 to 21 December 2020. Patients enrolled will be divided into two equal groups according to the urethral catheter inserted
The institutional ethics committee for research approved the study. Written informed consent was obtained from all participants. In addition to taking the patients' medical history and completing general and physical examinations, physicians will choose proper catheter size all perform catheterization using aseptic technique according to guidelines of proper aseptic catheterization. Urologist ensures comparable catheter size and amount of balloon inflation.
An aseptic non-touch technique (ANTT) must be used to obtain catheter specimen urine following these steps:
- After catheterization apply clamp 10 cm distal to meatus then after few minutes clean the drainage port with alcohol and allow to dry then insert the syringe tip into the drainage port.
- Three to five ml of urine collected in sterile disposable plastic cup at day zero (within 2 hours of catheterization), day ten and day twenty post catheterization.
- The urine subjected to routine urine analysis, urine culture and sensitivity.
Appropriate statistical tests will be used to indicate the frequency and type of CAUTI as well as to assess catheter tolerance in each arm, followed by a comparison to conclude the results.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Tamer A Abou Youssif, MD
- Phone Number: +201101200076
- Email: tamer.abouyoussif@alexmed.edu.eg
Study Locations
-
-
-
Alexandria, Egypt, 21646
- Recruiting
- Alexandria University Hospitals
-
Contact:
- Tamer A Abou Youssif, MD
- Phone Number: +201101200076
- Email: tamer.abouyoussif@alexmed.edu.eg
-
Contact:
- Alaa Abdel Hady, MBBCH
- Phone Number: +201223641864
- Email: medical_alaa@yahoo.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patient under age of 80 years old who need prolonged urethral catheterization (more than 2 weeks) as a method of bladder drainage.
Exclusion Criteria:
- Patients with current or recent symptomatic urinary tract infection.
- Antibiotic use currently or within 7 days prior to inclusion.
- Known hypersensitivity to latex, silver salts or hydrogel.
- Patients with recent surgical intervention in the urinary tract.
- Patients with anatomic or functional upper urinary tract issues (e.g reflux, stones, etc.)
- Uncontrolled DM. Patients on corticosteroid treatment. Immunosuppressed patients. Patients received pelvic irradiation.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Bactiguard urethral catheter
Group A: Fifty Patients with urethral catheter using noble metal alloy coated catheter (Bactiguard AB, Stockholm ,Sweden).
|
All Patients will have urethral catheterization with either Noble Metal Alloy coated catheter or Silicon Foley catheter.
|
|
Active Comparator: Silicone Foley urethral catheter
Group B: Fifty Patients with urethral catheter using silicone Foley catheter (Well Lead, Guangzhou, China).
|
All Patients will have urethral catheterization with either Noble Metal Alloy coated catheter or Silicon Foley catheter.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Urinary tract infection
Time Frame: 14 days
|
incidence of culture documented symotomatic urinary tract infection
|
14 days
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Catheter tolerance
Time Frame: 14 days
|
Catheter tolerance looks for discomfort or pain.
Discomfort is an uncomfortable sensation due to the presence of a foreign object in the urethra without pain.
The presence of actual pain is measured using VAS scoring system from zero to ten, so that a zero means no pain and a tenth means very severe pain.
|
14 days
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 0106462
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Urinary Tract Infections
-
NCT02446496Completed
-
NCT03151967CompletedUrinary Tract Infections (UTI's)
-
NCT03357614CompletedComplicated Urinary Tract Infections
-
NCT05651217TerminatedUrinary Tract Infection | Urinary Catheters
-
NCT02543827CompletedUrinary Tract Infection Bacterial
-
NCT02305342CompletedUrinary Tract Infections (UTIs)
-
NCT00702286Unknown
-
NCT00368888CompletedUrinary Tract Infection
-
NCT05577273Enrolling by invitationUrologic Diseases | Urinary Tract Disease
Clinical Trials on Urethral catheter
-
NCT01508767Completed
-
NCT03341468WithdrawnUrinary Catheter-Related Discomfort
-
NCT07287488RecruitingSimulation Study on Urethral Catheter Traction for Postoperative Hemorrhage Control After TURP
-
NCT03713411CompletedLower Urinary Tract Symptoms | Ureteral Catheterization | Flank Pain | Ureteroscopy | Complications; Urethral Catheter
-
NCT02074852CompletedCesarean Section | Urinary Infection | Urinary Catheter
-
NCT07421271Completed
-
NCT03424499CompletedNeurogenic Bladder Due to Spina Bifida (Disorder)
-
NCT06520423Active, not recruiting
-
NCT02761889CompletedAdenocarcinoma of the Prostate