Clinical Study on Disposable Sterile Urinary Catheter

February 16, 2023 updated by: Shandong Branden Med.Device Co.,Ltd

A Multicenter, Prospective, Randomized Controlled Clinical Study to Evaluate the Safety and Effectiveness of Disposable Sterile Urinary Catheter

This study is a multicenter, randomized controlled study, with the urinary tract infection rate at the time of catheter insertion for 1 week as the primary end point. By comparing the clinical safety and effectiveness of two kinds of urethral catheters, to evaluate the clinical application effect of one kind of urethral catheters.

Study Overview

Study Type

Interventional

Enrollment (Actual)

136

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Liaoning
      • Dalian, Liaoning, China, 110042
        • Liaoning Cancer Hospital & Institute

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 80 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • 18-80 year old patients;
  • Retained catheter ≥ 7 days;
  • Patients who were conscious and had good communication skills and volunteered to participate in the study.

Exclusion Criteria:

  • Pregnant and lactating female patients;
  • Diabetes patients;
  • Patients allergic to sulfadiazine, silica gel and stainless steel;
  • Urethral malformation, acute urethral injury, prostate disease, intermittent catheterization, suprapubic cystostomy and other patients who are not suitable for catheterization;
  • Patients who have used urinary catheters for a long time or had catheters retained within one week;
  • Patients who are participating in other clinical trials that interfere with this trial.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: trial group
Patients in this group used the disposable urinary catheter
The trial group was intervened with disposable sterile urinary catheter. The model of the trial group includes two chamber type (Fr8, Fr10, Fr12, Fr14, Fr16, Fr18, Fr20, Fr22, Fr24) and three chamber type (Fr16, Fr18, Fr20, Fr22, Fr24).
Active Comparator: control group
Patients in this group used super smooth antibacterial urinary catheter
the control group was intervened with ultra smooth antibacterial catheter. The control group models include single chamber (6Fr, 8Fr, 10Fr, 12Fr, 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr), double chamber (6Fr, 8Fr, 10Fr, 12Fr, 14Fr, 16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr, 28Fr, 30Fr), and three chamber (16Fr, 18Fr, 20Fr, 22Fr, 24Fr, 26Fr)

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Urinary tract infection rate
Time Frame: one week
In accordance with the "Diagnostic Criteria for Catheter associated Urinary Tract Infection" in the "Technical Guidelines for the Prevention and Control of Catheter associated Urinary Tract Infection (Trial)" formulated and issued by the Ministry of Health in 2011. Although the patient has no symptoms, he or she has endoscopic examination or catheterization within one week. If the number of Gram positive cocci colonies in urine culture ≥ 10 has 4 cfu/ml, and the number of Gram negative bacilli colonies ≥ 10 has 5 cfu/ml, he or she should be diagnosed as asymptomatic bacteriuria. If the patient has urinary tract irritation symptoms such as frequent urination, urgent urination, and painful urination, or has lower abdominal tenderness, renal area percussion pain, with or without fever (>38.0 ℃), it is symptomatic bacteriuria.
one week

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Success rate of catheterization
Time Frame: 10 minutes after catheterization
The success of catheterization is based on the evaluation of each instrument, which can be placed at the catheterization site as expected and catheterization can be carried out smoothly.
10 minutes after catheterization
level of urethral irritation
Time Frame: 10 minutes after catheterization
Level 0, no discomfort at all; Grade I, slight discomfort, but tolerable; Grade II, moderate discomfort, intolerable, urgency of urination, urethral pain, abdominal distension; Grade III, severe discomfort, extremely intolerable, obvious distension of lower abdomen, urethral pain, urgency of urination, and the desire to pull out the catheter, accompanied by restlessness, increased heart rate, and elevated blood pressure.
10 minutes after catheterization
level of urethral irritation
Time Frame: 72 hours
Level 0, no discomfort at all; Grade I, slight discomfort, but tolerable; Grade II, moderate discomfort, intolerable, urgency of urination, urethral pain, abdominal distension; Grade III, severe discomfort, extremely intolerable, obvious distension of lower abdomen, urethral pain, urgency of urination, and the desire to pull out the catheter, accompanied by restlessness, increased heart rate, and elevated blood pressure.
72 hours
level of urethral irritation
Time Frame: one week
Level 0, no discomfort at all; Grade I, slight discomfort, but tolerable; Grade II, moderate discomfort, intolerable, urgency of urination, urethral pain, abdominal distension; Grade III, severe discomfort, extremely intolerable, obvious distension of lower abdomen, urethral pain, urgency of urination, and the desire to pull out the catheter, accompanied by restlessness, increased heart rate, and elevated blood pressure.
one week
Incidence of device related adverse events
Time Frame: 72 hours
The safety of clinical use of the device was evaluated based on the incidence of adverse events related to the device that occurred after the subject placed the tube. Including: balloon leakage, rupture, catheter self falling off, difficulty in pulling out catheter, catheter blockage, urine retention, urine leakage, hematuria, urethral injury, etc; It can be judged according to clinical experience, and imaging methods can be used when necessary.
72 hours
Incidence of device related adverse events
Time Frame: one week
The safety of clinical use of the device was evaluated based on the incidence of adverse events related to the device that occurred after the subject placed the tube. Including: balloon leakage, rupture, catheter self falling off, difficulty in pulling out catheter, catheter blockage, urine retention, urine leakage, hematuria, urethral injury, etc; It can be judged according to clinical experience, and imaging methods can be used when necessary.
one week
time of catheter duration
Time Frame: one week
Time from insertion to removal of catheter
one week
rating of operation convenience
Time Frame: 10 minutes after catheterization
Including excellent: very convenient, good: relatively convenient, poor: poor convenience
10 minutes after catheterization
rate of packaging integrity
Time Frame: 10 minutes after catheterization
10 minutes after catheterization
rate of device defect rate
Time Frame: 10 minutes after catheterization
The package is damaged, the balloon cannot be inflated, and the balloon leaks or breaks
10 minutes after catheterization

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

December 11, 2019

Primary Completion (Actual)

September 12, 2021

Study Completion (Actual)

February 10, 2023

Study Registration Dates

First Submitted

December 1, 2022

First Submitted That Met QC Criteria

December 12, 2022

First Posted (Actual)

December 14, 2022

Study Record Updates

Last Update Posted (Estimate)

February 20, 2023

Last Update Submitted That Met QC Criteria

February 16, 2023

Last Verified

February 1, 2023

More Information

Terms related to this study

Other Study ID Numbers

  • B201703

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Urinary Tract Infection

Clinical Trials on disposable urinary catheter

Subscribe