RHYTHMIA vs CARTO in Redo Ablation Procedures for Atrial Fibrillation (MAP-AF)
RHYTHMIA vs CARTO in Redo Ablation Procedures for Atrial Fibrillation: MAP-AF Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Pulmonary venous conduction recovery is found in most patients undergoing redo ablation procedures for atrial fibrillation (AF). Identifying gaps in prior ablation lines is essential to achieve successful outcomes. High density mapping systems have been proposed to allow the identification of such gaps with speed and accuracy.
The MAP-AF study will compare RHYTHMIA vs CARTO in redo ablation of paroxysmal AF with assessment of both acute procedural profiles and clinical outcomes.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Ayman Hussein, MD
- Phone Number: 216-444-6171
- Email: husseia@ccf.org
Study Locations
-
-
Ohio
-
Cleveland, Ohio, United States, 44195
- Cleveland Clinic
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Adult patients (18-90 years of age) undergoing redo ablation procedures for paroxysmal AF regardless of the systems or energy sources used during the pre-study ablation procedure(s).
- Paroxysmal AF: defined as AF terminating within 7 days of onset either spontaneously or with electrical or medical cardioversion.
Exclusion Criteria:
- Persistent AF
- Prior cardiac surgery
- Patients with only AFL or AT as the documented recurrent arrhythmia after the pre-study AF ablation(s).
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Mapping with CARTO
CARTO (Biosense Webster) in conjunction with CONFIDENSE mapping module and PENTARRAY catheter
|
Redo-ablation of paroxysmal AF with high density mapping system, CARTO, in conjunction with CONFIDENSE mapping module and PENTARRAY catheter
|
|
Mapping with RHYTHMIA
RHYTHMIA (Boston Scientific) in conjunction with the 64-electrodes ORION mini-basket catheter.
|
Redo-ablation of paroxysmal AF with high density mapping system, RHYTHMIA, in conjunction with the 64-electrodes ORION mini-basket catheter.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
System is able to accurately identify gaps
Time Frame: At the time of procedure
|
Incidence of accurate identification of gaps in prior ablation lines by the system
|
At the time of procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Treatment success
Time Frame: Up to 12 months
|
Freedom from AF recurrence
|
Up to 12 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Ayman Hussein, MD, The Cleveland Clinic
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IRB 20-461
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Paroxysmal Atrial Fibrillation
-
NCT07191626Not yet recruitingParoxysmal Atrial Fibrillation | Paroxysmal Atrial Fibrillation (PAF)
-
NCT07036068Not yet recruiting
-
NCT07039032Not yet recruiting
-
NCT01687166CompletedParoxysmal Atrial Fibrillation (PAF)
-
NCT01456949CompletedParoxysmal Atrial Fibrillation (PAF)
-
NCT07100834CompletedCardiac Arrhythmia | Paroxysmal Atrial Fibrillation (PAF) | Atril Fibrillation
-
NCT01203241CompletedDrug-refractory Paroxysmal Atrial Fibrillation
-
NCT06144632CompletedDrug Refractory Paroxysmal Atrial Fibrillation
-
NCT01639495CompletedDrug Refractory Symptomatic Paroxysmal Atrial Fibrillation
-
NCT05883631Active, not recruitingAtrial Fibrillation | Arrhythmias, Cardiac | Arrhythmia | Atrial Flutter | Atrial Fibrillation, Persistent | Atrial Tachycardia | Atrial Arrhythmia | Atrial Fibrillation Paroxysmal | Atrial Fibrillation, Paroxysmal or Persistent
Clinical Trials on CARTO
-
NCT02476227Completed
-
NCT01651702Withdrawn
-
NCT00959205Unknown
-
NCT02929836UnknownAtrial Fibrillation
-
NCT00449085Withdrawn
-
NCT03198858CompletedParoxysmal Atrial Fibrillation
-
NCT01716663CompletedAtrial Fibrillation | Paroxysmal AF
-
NCT07572253Not yet recruiting
-
NCT00926783Completed