Accuracy of Half-guided Implant Placement
Accuracy of Half-guided Implant Placement With Machine-driven or Manual Insertion: a Prospective, Randomized Clinical Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Budapest, Hungary, 1088
- Semmelweis University Department of Periodontology
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- at least one edentulous maxillary premolar or molar site treated successfully by sinus floor elevation with a xenogenic bone substitute (cerabone, botiss biomaterials, Zossen, Germany) confirmed by preoperative cone-beam computed tomography
- full- mouth plaque and bleeding scores (FMPS and FMBS) <20%
- good patient compliance (including willingness to participate in the follow-up procedures)
- signed informed consent
Exclusion Criteria:
- clinically relevant diseases (e.g.: diabetes, rheumatism, cancer)
- systemic steroid or bisphosphonate use
- acute or chronic inflammatory processes
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Machine-driven group
In the machine-driven group, after guided implant bed preparation, implant insertion was performed with contra-angled handpiece.
|
The surgery was performed under local anaesthesia in both groups, half-guided implant placement was carried out based on randomization.
Other Names:
|
|
Experimental: Manual group
In the manual group, after guided implant bed preparation, implant insertion was performed with torque-wrench.
|
The surgery was performed under local anaesthesia in both groups, half-guided implant placement was carried out based on randomization.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Global coronal implant position deviation
Time Frame: 3 months after implant placement
|
Measurement: comparison of planned and actual implant position in a virtual model.
Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA).
Unit: mm
|
3 months after implant placement
|
|
Global apical implant position deviation
Time Frame: 3 months after implant placement
|
Measurement: comparison of planned and actual implant position in a virtual model.
Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA).
Unit: mm
|
3 months after implant placement
|
|
Horizontal coronal implant position deviation
Time Frame: 3 months after implant placement
|
Measurement: comparison of planned and actual implant position in a virtual model.
Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA).
Unit: mm
|
3 months after implant placement
|
|
Horizontal apical implant position deviation
Time Frame: 3 months after implant placement
|
Measurement: comparison of planned and actual implant position in a virtual model.
Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA).
Unit: mm
|
3 months after implant placement
|
|
Angular implant position deviation
Time Frame: 3 months after implant placement
|
Measurement: comparison of planned and actual implant position in a virtual model.
Tool: Linear measurement with Amira 5.4.0 (Thermo Fisher Scientific, USA).
Unit: mm
|
3 months after implant placement
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Implant insertion torque
Time Frame: During implant insertion
|
Measurement: Insertion torque.
Tool: torque wrech Unit: Ncm
|
During implant insertion
|
|
Implant insertion torque
Time Frame: During implant insertion
|
Measurement: Insertion torque.
Tool: surgical motor Unit: Ncm
|
During implant insertion
|
|
Duration of implant insertion
Time Frame: During implant insertion
|
Measurement: Duration of implant insertion Tool: stopwatch Unit: seconds
|
During implant insertion
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- Accuracy-Semmelweis-Perio
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.