Long-term Efficacy and Safety Research of Left Bundle Branch Pacing
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Shandong
-
Linyi, Shandong, China, 276000
- Linyi People's Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients who were predicted to require a high percentage of ventricular pacing in our center were enrolled in this study
Exclusion Criteria:
- Low rate of pacing, and loss to follow-up
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
left bundle branch potential group
the left bundle branch potential was recorded at implantation
|
model 3830, 69cm, Medtronic, Inc., Minneapolis, MN, USA
|
|
Purkinje potential group
the purkinje potential was recorded at implantation
|
model 3830, 69cm, Medtronic, Inc., Minneapolis, MN, USA
|
|
no-potential group
no potential was recorded at implantation
|
model 3830, 69cm, Medtronic, Inc., Minneapolis, MN, USA
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change from Baseline in left atrium diameter at 3 years
Time Frame: Baseline and 3 years
|
Echocardiography is measured by a professional using an ultrasound machine, record the following results: left atrium diameter (ms)
|
Baseline and 3 years
|
|
Change from Baseline in left ventricular end diastolic diameter at 3 years
Time Frame: Baseline and 3 years
|
Left ventricular end diastolic diameter (ms)
|
Baseline and 3 years
|
|
Change from Baseline in left ventricular ejection fraction at 3 years
Time Frame: Baseline and 3 years
|
Left ventricular ejection fraction (%)
|
Baseline and 3 years
|
|
Change from Baseline in pulmonary artery systolic pressure at 3 years
Time Frame: Baseline and 3 years
|
Pulmonary artery systolic pressure (mmHg)
|
Baseline and 3 years
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change from Baseline in threshold at 3 years
Time Frame: Baseline and 3 years
|
Threshold was measured with a pace-sensing analyser: threshold (V) at 0.5ms
|
Baseline and 3 years
|
|
Change from Baseline in impedance at 3 years
Time Frame: Baseline and 3 years
|
Impedance was measured with a pace-sensing analyser: impedance(Ω)
|
Baseline and 3 years
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Fingming Li, Linyi People's Hospital
Publications and helpful links
General Publications
- Huang W, Su L, Wu S, Xu L, Xiao F, Zhou X, Ellenbogen KA. A Novel Pacing Strategy With Low and Stable Output: Pacing the Left Bundle Branch Immediately Beyond the Conduction Block. Can J Cardiol. 2017 Dec;33(12):1736.e1-1736.e3. doi: 10.1016/j.cjca.2017.09.013. Epub 2017 Sep 22.
- Hou X, Qian Z, Wang Y, Qiu Y, Chen X, Jiang H, Jiang Z, Wu H, Zhao Z, Zhou W, Zou J. Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum. Europace. 2019 Nov 1;21(11):1694-1702. doi: 10.1093/europace/euz188.
- Huang W, Chen X, Su L, Wu S, Xia X, Vijayaraman P. A beginner's guide to permanent left bundle branch pacing. Heart Rhythm. 2019 Dec;16(12):1791-1796. doi: 10.1016/j.hrthm.2019.06.016. Epub 2019 Jun 22. No abstract available.
- Su L, Wang S, Wu S, Xu L, Huang Z, Chen X, Zheng R, Jiang L, Ellenbogen KA, Whinnett ZI, Huang W. Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study. Circ Arrhythm Electrophysiol. 2021 Feb;14(2):e009261. doi: 10.1161/CIRCEP.120.009261. Epub 2021 Jan 9.
- Ponnusamy SS, Muthu G, Kumar M, Bopanna D, Anand V, Kumar S. Mid-term feasibility, safety and outcomes of left bundle branch pacing-single center experience. J Interv Card Electrophysiol. 2021 Mar;60(2):337-346. doi: 10.1007/s10840-020-00807-w. Epub 2020 Jul 4.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Linyi People's Hospital
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.