A Comparison of Dynamic Vision Between College Athletes & Controls
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Aimie Kachingwe, Dr.
- Phone Number: 8186774684
- Email: aimie.kachingwe@csun.edu
Study Contact Backup
- Name: Margaret Roller, Dr.
- Phone Number: 8186774684
- Email: peggy.roller@csun.edu
Study Locations
-
-
California
-
Northridge, California, United States, 91330-8411
- California State University, Northridge, Jacaranda Hall 1578, 1576, 1574
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Currently a California State University Northridge student
- Provide consent to participate Able to complete the testing protocol.
Exclusion Criteria:
- Unable to complete entirety of testing protocol.
- The subject is unable to attain a minimum of 85 degrees per second of horizontal head rotation when performing the DVA test.
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Non-athlete college students with and without history of concussions
Non-athlete subjects included students currently enrolled in a Doctor of Physical Therapy (DPT) program served as a sample of convenience.
Non-athlete subjects were excluded if they were over the age of 30 years old to minimize the effect of age in the data analysis.
|
Dynamic Vision Acuity is tested with the Dynamic Vision Acuity (DVA) and Gaze Stabilization Test (GST) using the Bertec Vision Advantage System.
Other Names:
|
|
Students athletes with and without history of concussions
D1 student athletes currently enrolled in a large public university in the Los Angeles area.
Subjects volunteered to participate in this study and currently competing in one of the following teams: Men's and Women's soccer, Men's and Women's basketball, Women's water polo or Men's volleyball.
Athletes were eligible to participate if they were currently enrolled students, actively participating on the specified teams, provided consent to participate, and were able to complete the testing protocol.
|
Dynamic Vision Acuity is tested with the Dynamic Vision Acuity (DVA) and Gaze Stabilization Test (GST) using the Bertec Vision Advantage System.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Dynamic Visual Acuity (DVA)
Time Frame: August 31, 2021 - May 15, 2024
|
Subjects move their head at approximately 85 degrees per second per the standard test protocol.
A metronome automatically generated by the computer assists in maintaining the correct head speed.
When the sensor identifies 85 deg/sec, an optotype appears on the screen and the subject verbally identifies the optotype's orientation.
This continues with progressively smaller sized letter until the athlete is no longer able to correctly identify the orientation.
The computerized system uses a convergence algorithm to determine the accuracy of the response requiring 3 correct answers at the smallest letter size to assign a result.
The computer then compares each subject's DVA score to their SVA, which is expressed a Log of minimal angle resolvable units (LogMAR).
Simply, the computer considers the number of lines on an eye chart that are lost with head moving (DVA) compared to the head steady condition, known as static visual acuity (SVA)
|
August 31, 2021 - May 15, 2024
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Gaze Stabilization Test (GST)
Time Frame: August 31, 2021 - May 15, 2024
|
The subjects are asked to move their head in the horizontal plane and identify an optotype's orientation at increasing speeds.
The optotype remains the same size while the head speed increases.
A metronome is utilized to ensure correct head speeds which change throughout the test.
When the subject reaches or exceeds the minimum threshold for velocity as measured by a wearable gyroscope attached to the forehead, the optotype appears on the screen for 75 ms, and the subject verbally identifies the direction of the optotype.
The subject answers 3 of 5 trials correctly to confirm visual acuity for that velocity.
The velocity of head movement begins very slowly (10 deg / second) and the rotational speed increases incrementally as long as the subject is asymptomatic and can see clearly.
The test continues until the subject "fails", meaning the subject is unable to answer 3 of 5 trials correctly at a given velocity.
The maximum head velocity is measured in degrees/second
|
August 31, 2021 - May 15, 2024
|
|
Static Visual Acuity (SVA) test
Time Frame: August 31, 2021 - May 15, 2024
|
The SVA tests the subject's ability to see clearly with their head held still, similar to reading a Snellen eye chart.
An optotype is briefly flashed on the screen and the subject is asked to correctly identify its orientation (which directing the capital "E" is facing) as it gets progressively smaller.
Once the subject gives an inaccurate answer, the computer ends the test and provides their SVA baseline value based on the smallest optotype they could identify.
|
August 31, 2021 - May 15, 2024
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Dynamic Visual Acuity (DVA)
Time Frame: August 31, 2021 - May 15, 2024
|
Log of minimal angle resolvable units (LogMAR).
The number of lines on an eye chart that are lost with head moving (DVA) compared to the head steady condition, known as static visual acuity (SVA)
|
August 31, 2021 - May 15, 2024
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Aimie Kachingwe, Dr., CSUN
- Principal Investigator: Margaret Roller, Dr., CSUN
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IRB-FY23-271
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.