Validation of Numerical Simulation to Predict Proximal Deployment of Standard Stents (ProxSim)
Endoprosthesis treatment of aortic pathologies has become the reference in the vast majority of situations. The success of this treatment is conditioned by the choice of the endoprosthesis which must be as adapted as possible to the anatomy. This choice is currently based on manual geometric measurements performed on the preoperative scanner using conventional image processing software.
The morphological result of the implantation of the endoprosthesis in the aorta is obtained by a CT scan carried out postoperatively. This scanner makes it possible to define the positioning of the endoprosthesis, the apposition surfaces between the aorta and the endoprosthesis and to predict the long-term result.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Bron, France, 69500
- Recruiting
- Hôpital Louis Pradel
-
Contact:
- Antoine Millon, PU, PH
- Phone Number: +33 04.72.11.11.16
- Email: antoine.millon@chu-lyon.fr
-
Principal Investigator:
- Antoine Millon, PU, PH
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Any patient who has been treated for an aortoiliac aneurysm with a standard Medtronic Endurant aortic stent, standard Gore Excluder or conformable Gore Excluder
Exclusion Criteria:
- Patient who has objected to the use of their data.
- No preoperative scanner available or insufficient injection quality
- Preoperative scanner with slice thickness greater than 3 mm
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Patient who has been treated for an aortoiliac aneurysm
Any patient who has been treated for an aortoiliac aneurysm with a standard Medtronic Endurant aortic stent, standard Gore Excluder or conformable Gore Excluder
|
Analyzed on the post-operative scanner
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The accuracy of numerical simulation to predict the deployment at the level of the proximal neck of different types of standard stents used for the treatment of an aortoiliac aneurysm.
Time Frame: through study completion, an average of 1 year
|
Wwill be evaluated by measuring the diameter and the position of the center of the first 3 simulated proximal stents will be compared to those of the real stents, analyzed on the post-operative scanner
|
through study completion, an average of 1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 69HCL23_0342
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Surgery
-
NCT06637995CompletedThoracic Surgery | Spine Surgery | Upper Extremity Surgery | Lower Extremity Surgery | Intracranial Surgery | Extracranial Surgery | Intratemporal Surgery | Extratemporal Surgery | Neck Surgery
-
NCT05614869WithheldAbdominal Surgery | Orthopedic Surgery | Vascular Surgery | Cardiovascular Surgery
-
NCT00699244CompletedHand Surgery | Wrist Surgery | Forearm Surgery | Elbow Surgery
-
NCT01546272CompletedGynecological Surgery | Plastic Surgery | ENT Surgery
-
NCT03469570CompletedAbdominal Surgery | Pelvic Surgery | Non-Cardiac/ Non-Thoracic Surgery | Major Peripheral Vascular Surgery
-
NCT03981835CompletedSurgery | Cardiac Surgery | Surgery--Complications | Percutaneous Coronary Intervention
-
NCT06159517TerminatedCardiac Surgery | Cardiopulmonary Bypass | Thoracic Surgery | Vascular Surgery
-
NCT02964026CompletedCardiac Surgery | Thoracic Surgery | Heart Surgery | Heart Transplant
-
NCT07342010Not yet recruitingAnesthesia, Local | Foot Surgery | Hand Surgery | Walant Surgery
-
NCT07354841RecruitingCardiac Surgery | Cardiopulmonary Bypass | Heart Surgery | Aortic Valve Surgery | Cannulation | Coronary Surgery With Cardiopulmonary Bypass | Coronary Surgery | Arterial Cannulation | Venous Cannulation
Clinical Trials on Analyzed on the post-operative scanner
-
NCT06428877Completed
-
NCT02249520WithdrawnCoronary Artery Disease | Cancer
-
NCT06152601RecruitingIdiopathic Scoliosis | ERAS
-
NCT04466592CompletedEsophageal Neoplasms | Colonic Neoplasms | Stomach Neoplasm
-
NCT01551433Completed
-
NCT07330765Not yet recruiting
-
NCT05322434Not yet recruitingBreastfeeding | Breastfeeding Support
-
NCT05416866Not yet recruitingAnalgesia | Quadratus Lumborum Block | Colorectal | Laparoscopic