The Efficacy of the Longeviti ClearFit Implant in Craniectomies for Post-Operative Monitoring in Chronic Subdural Hematomas
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Bailey Yekzaman, MD
- Phone Number: 3166131041
- Email: byekzaman@kumc.edu
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Adult patients >18 years old; patients determined by surgeon to have a chronic subdural hematoma that is treated with craniectomy that would allow for implantation of a ClearFit cover
Exclusion Criteria:
- Pediatric patients, patient with allergy to the material the implant is made with (polymethylmethacrylate)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: ClearFit Longeviti Implant
Patients with chronic subdural hematomas that qualify for study and agree to participate will receive the ClearFit implant to cover the craniectomy site and have ultrasound imaging for their post-operative follow-up rather than CT/MRI, with exception of first initial post-op CT scan, and crossover to CT/MRI if clinically indicated or required for diagnostic purposes/patient safety
|
Implantation of ClearFit Longeviti Craniectomy Cover
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Patient Radiation
Time Frame: from time of implant to last follow-up, anticipate 1 year
|
Amount of radiation exposure to patient with ClearFit obtaining ultrasounds rather than CT compared to retrospective control group
|
from time of implant to last follow-up, anticipate 1 year
|
|
Patient cost
Time Frame: from time of implant to last follow-up, anticipate 1 year
|
Overall cost to patient with ClearFit compared to retrospective control group
|
from time of implant to last follow-up, anticipate 1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Quality of imaging
Time Frame: from time of implant to last follow-up, anticipate 1 year
|
Calculated based on number of cross-overs from ultrasound to CT or MRI, with noted reason for crossover.
Analysis of how often ultrasound is unable to be used/not feasible for post-operative monitoring of subdural, statistical analysis of crossover out of ultrasound into CT/MRI cranial imaging
|
from time of implant to last follow-up, anticipate 1 year
|
|
Provider experience caring for patient
Time Frame: from time of implant to last follow-up, anticipate 1 year
|
Survey of ease to care for patient in post-operative time period, ultrasound for imaging, transport of patient to obtain imaging, ease of access
|
from time of implant to last follow-up, anticipate 1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Flores AR, Srinivasan VM, Seeley J, Huggins C, Kan P, Burkhardt JK. Safety, Feasibility, and Patient-Rated Outcome of Sonolucent Cranioplasty in Extracranial-Intracranial Bypass Surgery to Allow for Transcranioplasty Ultrasound Assessment. World Neurosurg. 2020 Dec;144:e277-e284. doi: 10.1016/j.wneu.2020.08.114. Epub 2020 Aug 20.
- Hadley C, North R, Srinivasan V, Kan P, Burkhardt JK. Elective Sonolucent Cranioplasty for Real-Time Ultrasound Monitoring of Flow and Patency of an Extra- to Intracranial Bypass. J Craniofac Surg. 2020 May/Jun;31(3):622-624. doi: 10.1097/SCS.0000000000006225.
- Belzberg M, Shalom NB, Yuhanna E, Manbachi A, Tekes A, Huang J, Brem H, Gordon CR. Sonolucent Cranial Implants: Cadaveric Study and Clinical Findings Supporting Diagnostic and Therapeutic Transcranioplasty Ultrasound. J Craniofac Surg. 2019 Jul;30(5):1456-1461. doi: 10.1097/SCS.0000000000005454.
- Belzberg M, Shalom NB, Lu A, Yuhanna E, Manbachi A, Tekes A, Huang J, Brem H, Gordon C. Transcranioplasty Ultrasound Through a Sonolucent Cranial Implant Made of Polymethyl Methacrylate: Phantom Study Comparing Ultrasound, Computed Tomography, and Magnetic Resonance Imaging. J Craniofac Surg. 2019 Oct;30(7):e626-e629. doi: 10.1097/SCS.0000000000005651.
- Lee RP, Meggyesy M, Ahn J, Ritter C, Suk I, Machnitz AJ, Huang J, Gordon C, Brem H, Luciano M. First Experience With Postoperative Transcranial Ultrasound Through Sonolucent Burr Hole Covers in Adult Hydrocephalus Patients. Neurosurgery. 2023 Feb 1;92(2):382-390. doi: 10.1227/neu.0000000000002221. Epub 2022 Nov 15.
- Doron O, D'Amico RS, Langer DJ. The Cranial Window: Opportunities for the Use of Bedside Ultrasound Facilitated by Sonolucent Implants in Neurosurgical Patients. World Neurosurg. 2022 Sep;165:142-144. doi: 10.1016/j.wneu.2022.05.084. Epub 2022 May 23. No abstract available.
- Niesen WD, Rosenkranz M, Weiller C. Bedsided Transcranial Sonographic Monitoring for Expansion and Progression of Subdural Hematoma Compared to Computed Tomography. Front Neurol. 2018 May 28;9:374. doi: 10.3389/fneur.2018.00374. eCollection 2018.
Helpful Links
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Cerebrovascular Disorders
- Brain Diseases
- Central Nervous System Diseases
- Nervous System Diseases
- Vascular Diseases
- Cardiovascular Diseases
- Wounds and Injuries
- Pathologic Processes
- Chronic Disease
- Disease Attributes
- Hemorrhage
- Craniocerebral Trauma
- Trauma, Nervous System
- Intracranial Hemorrhages
- Intracranial Hemorrhage, Traumatic
- Hematoma, Subdural
- Hematoma, Subdural, Chronic
- Hematoma
Other Study ID Numbers
Other Study ID Numbers
- UKansasClearFit
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.