Fixation of Fracture Neck of Femur in Children
Fixation of Fracture Neck of Femur in Children by Cannulated Screws VS Wagner's Technique.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
In the pediatric population, fracture of the neck of femur is relatively uncommon usually caused by high-energy trauma, but with high complication rates, despite appropriate diagnosis and management. The high rate of complication is due to the vascular anatomy of proximal femur.
Fracture neck of femur can be classified into transphyseal , transcervical (which is commonest), basal and pertrochanteric.
Complications include avascular necrosis, delayed union and non-union. Multiple fracture fixation methods have been used, with the overall goal being anatomic reduction with stable fixation.
Methods of fixation vary based on age, Delbet classification and dispalcement of the fracture.
Two types of fixation of pediatric fracture NOF of interest are cannulated screw (CS) and the Wagner technique.
Most studies agree that 3 screws are enough, and they should be inserted parallel in triangular arrangement with an inverted triangle. The CS should apply compression to the fracture (compression screws) to minimize the remaining fracture gap and accelerate the healing process. The use of washers allows for higher compression forces and thus increases the initial stabilization. CS shouldn't pass the physis in pediatrics to allow normal continuation of growth in children. The stability of fixation by CS has been shown to be affected by several factors: screw type, number, thickness, position and direction. Some of CS disadvantages are that they are mechanically unstable, failure of stabilization leads to varus malunion and it may lead to slipped capital femora epiphysis (SCFE) above the tips of the screws(especially short working distance in transcervical fractures).
The Wagner technique consists of the use of two or three k-wires bent as close as possible to the shaft and fixed to the shaft by two cerclage wires. Some advantages of this method are that k-wires can cross the physis and give good stability to the fracture with normal continuation of growth(especially in transphyseal & transcerviacal fractures). Hip spica is recommended to give more stabilization to the fixation and neutralize forces around the fixed fracture.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Mina Maged, Resident
- Phone Number: 01205188908
- Email: Menamaged54@gmail.com
Study Contact Backup
- Name: Hesham Mohammed, Staff member doctor
- Phone Number: 01007780689
- Email: Drhesham20@aun.edu.eg
Study Locations
-
-
-
Assiut, Egypt
- Assiut University
-
Contact:
- Mina Maged
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- clinical diagnosis of fracture neck of femur
- children with age less than 14 years old
Exclusion Criteria:
- pathological fracture
- patients with cerebral palsy
- Associated ipsilateral femoral shaft fracture
- comminuted fractures
- old fracture ( > 2 weeks)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Patients with fracture neck of femur fixed by cannulated screws
Fix the fracture by two to three cannulatef screws
|
Fixation of fracture neck of femur by cannulated screws or wagner's technique
|
|
Active Comparator: Patient with fracture neck of femur fixed by wagner's technique
Fix the fracture by three to four k-wires
|
Fixation of fracture neck of femur by cannulated screws or wagner's technique
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The better method for fixation of fracture neck of femur
Time Frame: Baseline, one year
|
The rate of cases with complications with avascular necrosis in each method
|
Baseline, one year
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Children NOF fracture fixation
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.